DC Power Relays
High-voltage, High-current Loads • A compact relay (73 x 36 x 67.2 mm (L x W x H)) capable of switching 400-V 60-A DC loads. (Capable of interrupting 600 A at 300 VDC max.) • The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads.
Download DC Power Relays
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
CSM PCB Con CN J 1 3 - omronfs.omron.com
omronfs.omron.comA-20 最新の商品情報・便利な情報は www.fa.omron.co.jp/ コネクタ 共通の注意事項 コネクタ 共通の注意事項 挿抜作業について ・通電中の挿抜作業時および抜去後に、コネクタの接点 …
CSM XM2 XM3 AC DS J 1 8 - omronfs.omron.com
omronfs.omron.com2 最新の商品情報・便利な情報は www.fa.omron.co.jp/ XM2/XM3 Dサブコネクタ X M 2 / X M 3 注1. 1個のコネクタに固定具は2個必要です。 注2. 形XM3K/Lには取付できません。
Solid State Pressure Sensors D8M - omronfs.omron.com
omronfs.omron.comCompact D8M solid state pressure sensors provide reliable detection for gas and air inflow for burner controls in water heaters, furnaces and other gas-fired devices.
G5V-2 - omronfs.omron.com
omronfs.omron.com2 G5V-2 Low Signal Relay G 5 V-2 Ratings Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C.
G6B - Omron
omronfs.omron.com3 G6B PCB Power Relay G 6 B Models for Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G6B-1114P-US DC5 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VDC.
Solid State Relays Common Precautions
omronfs.omron.com2.Inductive Noise Do not wire power lines alongside the input lines. Inductive noise may cause the SSR to malfunction. If inductive noise is imposed on the input terminals of the SSR, use the following cables according to the type of inductive noise, and reduce the noise level to less than the must release voltage of the SSR.
G7L - Omron
omronfs.omron.com• Miniature size for maximum switching power, particularly for inductive loads. • Flame-resistance materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals, and DIN track mounting available. • Conforms to UL, CSA, TUV and meets IEC950. • Safety design with contact gap of 3 mm.
G2RL - Omron
omronfs.omron.comTest conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 Sample: G2RL-24 12 VDC Number of relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing
G6S - Omron
omronfs.omron.comElectrical 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC Ambient operating temperature-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation)
G2R - Omron
omronfs.omron.com3 G2R PCB Power Relay G 2 R Quick-connect Terminal (#187) Full-wave Rectifier For Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G2R-1A-T AC12 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VAC.
Related documents
Guide To Electrical Safety Testing - Hipot
go.hipot.comstatic discharge (not the operator from high voltage hazards). Do NOT use anti-static robes, benches, or floor mats during electrical safety testing. All of these items are used to intentionally ground the test operator which can cause injury or death to a high voltage test operator. Such stations are not designed for voltages above 250 VAC.
Liquid-filled power transformers - ABB
library.e.abb.comcountries, producing transformers, switchgear, breakers, capaci-tors and other products for high and medium voltage applications. The division contains three business units: High Voltage Products, Medium Voltage Products and Transformers.
High, Liquid, Power, Breaker, Filled, Voltage, Transformers, High voltage, Liquid filled power transformers
Short-Circuit Current Ratings - Rockwell Automation
literature.rockwellautomation.comcoordinated high fault short-circuit solutions for fused-disconnects, circuit breakers, motor starters, soft starters and component drives. The one-line “Bills-of-Material” provides coordinated high fault SCCR ratings for all power devices used in the circuit, saving customers time and effort to find and determine these ratings.
High, Automation, Breaker, Rockwell automation, Rockwell, Crsc
PWRview™ Owner’s Manual
www.generac.comElectrocution. High voltage is present at transfer switch and terminals. Contact with live terminals will result in death or serious injury. (000104) DANGER Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000145) DANGER Electrocution. In the event of electrical accident, immediately ...
Substation Maintenance and Construction Manual Circuit ...
www.pge.comtable of contents (continued) pacific gas and electric company substation maintenance and construction manual circuit breakers booklet
Company, Electric, Pacific, Breaker, Pacific gas and electric company