EzyBrace Systems - GIB
plasterboard linings. — Enhanced thermal performance. — ®Allows internal walls lined with GIB plasterboard on both sides and fastened off as per the standard fixing requirements of the current GIB® Site Guide to contribute bracing resistance. — …
Download EzyBrace Systems - GIB
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Deflection Head Details JANUARY 2006 - GIB®
www.gib.co.nzFire rated sealant 2 strips of GIB¤ Plasterboard (same as linings) Wall frame top channel Steel studs GIB¤ Plasterboard wall linings (as specified to …
Fire Rated Systems - gib.co.nz
www.gib.co.nzFire rated floor/ceiling systems Fire rated floor/ceiling Specification number LB/ NLB STC/ Rw FRR IIC Lining requirements Page Timber joist GBFC 15 LB 38/38 15/15/15 31 1 layer 13mm GIB® Standard 54 GBFC 30 LB 39/40 30/30/30 32 1 layer 13mm GIB Fyreline® 56 GBFC 45 LB 39/40 45/45/45 32 1 layer 13mm GIB Fyreline® 56 GBFC 60 LB 39/40 60/60/60 32 1 layer 16mm GIB Fyreline® 58
System, Trade, Fire, Fire rated, Fire rated systems, Systems fire rated
Intertenancy Barrier Systems for Terrace Homes
www.gib.co.nzThe GIB® Wall Clips are intended to melt on the fire side only, allowing collapse without damage to the remaining system. Noise control performance The noise control performance of the GIB® Intertenancy Barrier Systems for Terrace Homes is expressed in terms of Sound Transmission Class (STC) and Weighted Sound Reduction Index (Rw).
System, Barriers, Class, Walls, Transmissions, Sound, Sound transmission class, Caterer, Intertenancy, Intertenancy barrier systems for terrace
Noise Control Systems - GIB
www.gib.co.nzThis technical document provides noise control systems for designers, specifiers and builders. This information can be used during the building design process to help select systems to achieve the desired level of acoustic comfort. GIB Noise Control ® Systems have been independently tested and evaluated and can be depended on to perform.
System, Control, Noise, Noise control, 174 system, Noise control systems
SyStem and InStallatIon manual - GIB
www.gib.co.nz• GIB Quiet Clip ® for use in GIB Noise control systems Alternative method • Directly by fastening with pairs of min GIB Grabber® 32mm x 8g wafer head screws through the flange (consult span tables pg 5) • Alternatively pairs of min 45mm x 2.8mm FH nails can be used • For fixing to steel framing a drill tip screw is recommended
Manual, System, Installation, Quiet, System and installation manual
Related documents
NBS - Reference Specification - SE Controls
www.secontrols.comK10 PLASTERBOARD DRY LININGS FOR WALLS, PARTITIONS AND CEILINGS 132 K11 RIGID SHEET FLOORING, SHEATHING, DECKING, SARKING, LININGS AND CASINGS 136 ... Z20 FIXINGS AND ADHESIVES 278 Z21 MORTARS 280 Z22 SEALANTS 282 Page 4 of 282. ... Fixing of services: Submit typical details of locations, types and methods of fixing of services …
The Posi-Joist Technical Handbook
irp-cdn.multiscreensite.comceiling plasterboard. The responsibility for specification of the plasterboard and its fixings rests with the Building Designer. Posi-Joist floors with a variety of build-ups have been independently tested to both BS and EN Standards and those Posi-Joist floors providing 30 minutes fire resistance are listed in the tables below. Fire Resistance
Technical Manual - CSR Hebel
hebel.com.au• For proprietary fixings by others, contact the manufacturer or visit the appropriate website. Fixing selector Determine the grade of fixing (Selection table) to suit your application and select a fixing (Types of Fixing Table). Use ‘Design Tables’ to check the adequacy of the fixing and contact the manufacturer for confirmation.
Identification
www.british-gypsum.comTable 1: Glasroc F FireCase fixings. Board thickness (mm) Min. fixing length Board-to-board fixing Board-to-metal fixing 15 Glasroc F FireCase Screws 40mm ... Gyproc plasterboard lining. Refer to construction detail 16 on page 3.14. – For further information please please refer to Technical Support on .
WHITE BOOK - CasoLine MF - Rossendale
www.rossendale.gov.ukBoard fixings for Gyptone boards should be at 230mm centres across board-ends and through the field of the board. Board fixings for Rigitone boards should be at 150mm centres at perimeters and 230mm through the field of the board. A special procedure is used for fixing and jointing Rigitone boards.