Search results with tag "Plasterboard"
FIXING TO PLASTERBOARD AND PLASTERBOARD …
www.woodtools.nov.ru1 2 3 Image 1 shows the face of the Redidrive when it has been screwed into the plasterboard.
An investigation into the use of plasterboard …
www.hse.gov.ukPrepared by the Health and Safety Laboratory for the Health and Safety Executive 2010 Health and Safety Executive An investigation into the use of plasterboard
EzyBrace Systems - GIB
www.gib.co.nzplasterboard linings. — Enhanced thermal performance. — ®Allows internal walls lined with GIB plasterboard on both sides and fastened off as per the standard fixing requirements of the current GIB® Site Guide to contribute bracing resistance. — …
Boundary Wall System - gyprock
www.gyprock.com.aufixing plasterboard/wallboard linings to timber framing, and for laminating plasterboard. Fine thread screws and clouts may also be used for fixing to timber. Application Size (Framing) Pack Qty Order No. 1x10mm/ Laminating 16mm 6g x 25mm (softwood/ hardwood) Loose 1000 169067 Collated 1000 162775 1x13/16mm 6g x 32mm (softwood/ hardwood) Loose ...
Spandrel panels FINAL - 04.01 - NHBC
www.nhbc.co.uk12.5mm plasterboard across butt joint between panels first and second layers of plasterboard individually fixed into each stud with screws at 300mm max. vertical centres or nails at 150mm max. vertical centres screws/nails to penetrates studs by at least 25mm joints in cover strips to be staggered 150mm min. Section-view B-B of joint in ...
6. INSTALLATION - Building and Construction Authority
bca.gov.sg• Plasterboard screws should be spaced i. <300mm for butt joints ii. <200mm for angles joints iii. 10 to 16mm from edges and ends of plasterboard sheets • Ensure securing process of the board onto the vertical stud does not cause tilting of flange. Application of drywall screws shall begin from centre outwards. • Install screws from ends
INSTALLATION GUIDE - Rondo
www.rondo.com.au3.FIX PLASTERBOARD Screw fix plasterboard, tape and set joints and sand off as lining manufacturers recommendations. FIGURE 8: KEY-LOCK® USED TO BATTEN-OUT MASONRY WALL Maximum spacings: For 308: 900mm For 129: 1200mm 25mm 25mm 600mm maximum Anchor clips (eg. BETAGRIP) BetaGrip® Clips can be installed to a wall with either one centre …
MSDS Plasterboard December 2012
www.bgcplaster.com3 BGC MSDS Plasterboard December 2012December 2012 Wash work clothes regularly and do not shake out dust. Eye Protection: Wear dust resistant non-fogging safety goggles or glasses, which comply with Australian
Guide to Standards and Tolerances (currently under review)
www.vba.vic.gov.au9.07 Covering movement control joints and damp-proof courses 49 9.08 Cracking in applied finishes used over lightweight substrate 49 9.09 Rendered surfaces 49 9.10 Cracking in external mouldings 50 9.11 Plasterboard sheeting 50 9.12 Other sheeting systems 50 9.13 Level of finish for plasterboard 50
COVERING A MASONRY WALL WITH GYPROCK …
www.gyprock.com.auHOW TO FIX GYPROCK® PLASTERBOARD TO A BRICK WALL OR BLOCK MASONRY WALL Covering a brick or block masonry wall with plasterboard is an ideal way to lighten a room or create a smooth surface with a cavity
The Posi-Joist Technical Handbook
irp-cdn.multiscreensite.comceiling plasterboard. The responsibility for specification of the plasterboard and its fixings rests with the Building Designer. Posi-Joist floors with a variety of build-ups have been independently tested to both BS and EN Standards and those Posi-Joist floors providing 30 minutes fire resistance are listed in the tables below. Fire Resistance
Timber Frame v10 - Design for Homes
www.designforhomes.orgTimber Frame Construction Performance Fire protection Plasterboard is designated a 'material of limited combustibility' within the Building Regulations 1991.
A Homeowner’s Guide To Wall Insulation
www.seai.iefixing insulation to the inner surfaces of your external walls. This usually involves attaching an insulation board to the walls and covering it with a vapour barrier layer and plasterboard. While this is often a more affordable option of insulation, it should be noted that you will lose room space and will have to
Bushfire Roofing Systems - Bradford Insulation
www.bradfordinsulation.com.auPlasterboard ceiling lining Roof rafter Roof batten Figure 4.2.2.b Valley Detail – Steel Roof (BAL-12.5 – BAL-40) Metal roof sheetInstall Enviroseal HTS to the entire roof area over the top of the battens. Multitel BAL12.5 – 40 Blanket to be laid over the top of the sarking extending into the outer edge of the valley gutter. Compress with
INSTRUCTION MANUAL - Creda
www.credaheating.co.uksuitable fixing. SUGGESTED FIXINGS SOLID BRICK/BLOCK: No. 10 size high temperature resistant plastic inserts, 8mm drill bit. Drill hole 15mm deeper than plastic insert length. PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.
JJI-JOISTS TECHNICAL MANUAL - James Jones and Sons Limited
www.jamesjones.co.ukPlasterboard specification as per manufacturer's guidelines. A water cylinder/thermal store load provision of 150kg has been allowed unless noted otherwise. JJI-Joists at 600mm centres unless noted otherwise. Loading: 0.500 kN/m2 Permanent Self Weight 0.450 kN/m2 Permanent Partition 1.500 kN/m2 Medium Term Live Load unless otherwise noted.
K118 Insulated Plasterboard - Kingspan Insulation
kingspaninsulation.co.uk2 Assumptions The U−values in the tables that follow have been calculated, under a management system certified to the BBA Scheme for Assessing
TP10 8th Issue Sept 21
ks-kentico-prod-cdn-endpoint.azureedge.netPlasterboard has a thermal conductivity of 0.018 W/mK. NB When calculating U-values to BS / I.S. EN ISO 6946: 2017, the type of mechanical fixing used may change the thickness of insulation required. The effect of fixings for Kingspan Kooltherm® K118 in the U-value calculations for Figures 1a, 1b, 1c, 1d, 2a, 2b,
NBS - Reference Specification - SE Controls
www.secontrols.comK10 PLASTERBOARD DRY LININGS FOR WALLS, PARTITIONS AND CEILINGS 132 K11 RIGID SHEET FLOORING, SHEATHING, DECKING, SARKING, LININGS AND CASINGS 136 ... Z20 FIXINGS AND ADHESIVES 278 Z21 MORTARS 280 Z22 SEALANTS 282 Page 4 of 282. ... Fixing of services: Submit typical details of locations, types and methods of fixing of services …
Calculating the Total R-Value
watermark.abcb.gov.auplasterboard Bulk insulation Air space Steel frame Pliable building membrane Figure 1 Illustration of a wall system with solid concrete exterior and steel wall frame Scenario A Class 6 shop is located in climate zone 3. A wall component consists of 100 mm solid concrete, a 62 mm ventilated, non reflective air space, a pliable building membrane ...
INTERIOR FINISH OF WALLS AND CEILINGS
www.constructionknowledge.netPlasterboard or gypsum lath is used for plaster base. It is available in thickness starting at 3/8 inch, widths 16 and 24 inches, and length is usually 48 inches. Because it comes in manageable sizes, it’s widely used as a plaster base instead of metal or wood lath for both new construction and renovation. This material is not
Environmental benefits of recycling
www.epa.nsw.gov.au7. Plasterboard Paper and cardboard 8. Cardboard/paper packaging 9. Newsprint/magazines 10. Liquid paper board 11. Office Paper Organics 12. Timber pallets/packaging 13. Mixed food and garden organics 14. Garden organics Glass 15. Glass containers 16. Sheet/laminated glass Plastics 17. PET #1 18. HDPE #2 19. PVC #3 20. Mixed plastics #7 21 ...
Smoke Alarm User’s Guide - Kidde
www.kidde.commounting in plasterboard or similar surface, drill 3/16” holes and use the plastic anchors provided.) Anchors are not required for mounting on hard surfaces such as wood. ATTACHING AND ACTIVATING THE ALARM Alarm
Resene Sureseal - pigmented sealer | D42 - Technical ...
www.resene.co.nz• Paperfaced plasterboard • Plaster - gypsum and solid • Plaster glass • Stucco • Timber . Performance. 1. Lower odour formulation, less than 1% aromatic hydrocarbon content. 2. Excellent adhesion to all substrates. 3. Resene Sureseal is the recommended
BOXSPAN RESIDENTIAL SPAN TABLES
www.spantec.com.auplasterboard ceiling and Boxspan beams only). • Live Loads: 0.25kPa (non trafficable roof). The span tables have NOT considered the 1.4kN maintenance loading and propping and crawl boards are recommended when accessing the roof. • Wind Loads: Wind classes in accordance with AS4055:2012 and wind pressures in accordance
Conventions for U-valuecalculations - BRE
www.bre.co.uk3.6 Gypsum plasterboard 5 3.7 Structural timber 5 3.8 Metals and alloys 5 3.9 Thermal conductivity of other materials 6 3.10 Reflective foil products 6 3.10.1 Bubble sheet with aluminium foil facing 6 3.10.2 Multi-foil insulation 6 4 Issues concerned with U-value calculations 7 4.1 Surface resistance 7 4.2 Mortar joints in masonry construction 7
Gyproc SoundBloc 12 - british-gypsum.com
www.british-gypsum.comEither cut the board with a plasterboard saw, or score the front face paper with a sharp knife, snap it over a straightedge, then cut the back face paper. Cut holes for things like socket boxes using a utility saw. Fixing Fix the board with the decorative side facing outwards to receive finishes. Install fixings at least 13mm from cut
Horizontal Installation Technical Specification
www.jameshardie.co.nzLining or a 10mm plasterboard. Table 1 Insulation capability Climate zone* R-value requirement* Minimum cavity insulation infill requirement 1 and 2 1.9 m2 ºC/W R2.0* 3 2.0 m2 ºC/W R2.2* Total construction R-value depends on the insulation material used and the framing ratio. The insulation material R-values
THERMAL BRIDGING GUIDE - LABC
www.labc.co.ukjoints and wall-ties in masonry construction or timber or steel studs in framed construction. Where the frequency of these is known and consistent their effects can be accounted for directly in the U-value calculation for the building element itself. ... Plasterboard on plaster dabs
K112 Framing Board
ks-kentico-prod-cdn-endpoint.azureedge.netKingspan Kooltherm® K118 Insulated Plasterboard has been ignored in these calculations, as the insulation layer penetrated is not the main insulation layer. For the purposes of timber frame calculations which feature insulating sheathing, the use of stainless steel fasteners of cross sectional area 7.45 mm2 has been assumed at a density of 4.4 per
Identification
www.british-gypsum.comTable 1: Glasroc F FireCase fixings. Board thickness (mm) Min. fixing length Board-to-board fixing Board-to-metal fixing 15 Glasroc F FireCase Screws 40mm ... Gyproc plasterboard lining. Refer to construction detail 16 on page 3.14. – For further information please please refer to Technical Support on .
The Basics of Signal Attenuation - CAS Dataloggers
www.dataloggerinc.comNov 16, 2016 · WHITE PAPER . Free Space Loss Formulas . Items with losses to be added dB: Human body 3 . Cubicles 3 to 5 Window, Brick Wall 2 Brick Wall next to a Metal Door 3 Glass Window (non tinted) 2 Clear Glass Window 2 Office window 3 Plasterboard wall 3 Marble 5 Glass wall with metal frame 6 Metal Frame Glass Wall Into Building 6 DataLoggerInc.com The …
Plasterboard FGD gypsum - SMARTWaste
www.smartwaste.co.ukin the European waste catalogue (11). ... • Industrial symbiosis through co-location of industries (as with plasterboard/FGD gypsum) Page 8 of 8 References
Similar queries
FIXING TO PLASTERBOARD AND PLASTERBOARD, Plasterboard, Systems, Fixing, Fixing plasterboard, Spandrel panels, Joints, COVERING A MASONRY WALL WITH GYPROCK, GYPROCK, Fixings, Timber, And plasterboard, Bushfire Roofing Systems, K118 Insulated Plasterboard, Insulation, Certified, Smoke Alarm, Kidde, BOXSPAN RESIDENTIAL SPAN TABLES, Conventions for U, THERMAL BRIDGING GUIDE, Plasterboard FGD gypsum, European waste catalogue, Plasterboard/FGD gypsum