G6B - Omron
2.The P6B sockets are designed to be used with G6B- @@@@P(-FD)-US-P6B relays. Only use G6B relays that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B" from their model numbers with the sockets. 3.The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models
Download G6B - Omron
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
CSM PCB Con CN J 1 3 - omronfs.omron.com
omronfs.omron.comA-20 最新の商品情報・便利な情報は www.fa.omron.co.jp/ コネクタ 共通の注意事項 コネクタ 共通の注意事項 挿抜作業について ・通電中の挿抜作業時および抜去後に、コネクタの接点 …
CSM XM2 XM3 AC DS J 1 8 - omronfs.omron.com
omronfs.omron.com2 最新の商品情報・便利な情報は www.fa.omron.co.jp/ XM2/XM3 Dサブコネクタ X M 2 / X M 3 注1. 1個のコネクタに固定具は2個必要です。 注2. 形XM3K/Lには取付できません。
Solid State Pressure Sensors D8M - omronfs.omron.com
omronfs.omron.comCompact D8M solid state pressure sensors provide reliable detection for gas and air inflow for burner controls in water heaters, furnaces and other gas-fired devices.
G5V-2 - omronfs.omron.com
omronfs.omron.com2 G5V-2 Low Signal Relay G 5 V-2 Ratings Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C.
Solid State Relays Common Precautions
omronfs.omron.com2.Inductive Noise Do not wire power lines alongside the input lines. Inductive noise may cause the SSR to malfunction. If inductive noise is imposed on the input terminals of the SSR, use the following cables according to the type of inductive noise, and reduce the noise level to less than the must release voltage of the SSR.
DC Power Relays
omronfs.omron.comHigh-voltage, High-current Loads • A compact relay (73 x 36 x 67.2 mm (L x W x H)) capable of switching 400-V 60-A DC loads. (Capable of interrupting 600 A at 300 VDC max.) • The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads.
G7L - Omron
omronfs.omron.com• Miniature size for maximum switching power, particularly for inductive loads. • Flame-resistance materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals, and DIN track mounting available. • Conforms to UL, CSA, TUV and meets IEC950. • Safety design with contact gap of 3 mm.
G2RL - Omron
omronfs.omron.comTest conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the relays to check the number of malfunctions. Requirement: None malfuction 100 m/s2 Sample: G2RL-24 12 VDC Number of relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing
G6S - Omron
omronfs.omron.comElectrical 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC Ambient operating temperature-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation)
G2R - Omron
omronfs.omron.com3 G2R PCB Power Relay G 2 R Quick-connect Terminal (#187) Full-wave Rectifier For Ultrasonically Cleanable Note: When ordering, add the rated coil voltage to the model number. Example: G2R-1A-T AC12 However, the notation of the coil voltage on the produc t case as well as on the packing will be marked as @@ VAC.
Related documents
MAGNETIC MOTOR STARTERS AND MAGNETIC CONTACTORS
sg.mitsubishielectric.comPerformance with a refined new design and functional beauty ADVANCED AND EVER ADVANCING MAGNETIC MOTOR STARTERS AND MAGNETIC CONTACTORS (Note) This mark indicates EC Directive Compliance.
General Purpose Relays - Farnell
www.farnell.comThese miniature plug-in relays have a 10 Ampere resistive rating (except for RS/RSD41), the same as the Type K plug-in relays, but are much smaller. The compact size of these relays makes them ideal for downsizing equipment. • SPDT through 4PDT † AC or DC Operated † Horsepower rated h RS41 and RSD41 relays have a B300 rating. S – Stocked
General Purpose, Interposing, Solid-State and Specialty Relays
literature.rockwellautomation.com• Same sockets can be used for DPDT or 4PDT versions which improves fl exibility and reduces inventory 700-HP • Plug-in pin style (PCB) terminals • Economical PCB style design Specialty Relays Features 700-HG • Auxiliary snap action switch versions • Popular 3V HVAC applications 700-HHF • Blade-style quick connect terminals
FINDER Relays 40 Series - Miniature PCB/Plug-in relays 8 ...
www.finder-relais.net40.51, 40.52 & 40.61 relays PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets † DC coils & AC coils † Cadmium Free option available † 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts † UL Listing (certain 40.61 relay/socket combinations) † Flux proof: RT II standard, (RT III option) † 95 series ...
Switches & Pilot Devices 16mm A6 - IDEC Corporation
www.idec.comDisplay Lights Relays & Sockets Timers Terminal Blocks Circuit Breakers Switches & Pilot Devices A6 Series — Miniature Switches and Pilot Devices: 16mm Key features: 16mm (5/8”) mounting hole LED illumination Compact design saves space Momentary, Maintained, Selectors, and E-Stops Gold-clad Silver contacts for reliable low level switching
Facilities Management Monthly Report
www.wku.eduEnergy Management replaced failed relays on Knicely AHUs 1-4 Replaced bearings on Gary Ransdell Energy Recovery Unit, replaced wheel belt ... Repaired main lighting circuit in back court yard at south campus/ several bad ballast, lamps, wiring and sockets.
1 Form A/1 Form C/2 Form A/2 Form C, 5 A/10 A, Power relays
www3.panasonic.biz1 Form A/1 Form C/2 Form A/2 Form C, 5 A/10 A, Power relays JW RELAYS Power relays (Over 2 A) 20 ... For the sockets, please refer to the “JW RELAYS PC board sockets”." Type No. " is ordering part number for non Japanese market. " Part No. " …