User's Manual - SJM
Electrosurgery. Do not use electrosurgical devices in the vicinity of an implanted device. If electrocautery is necessary, use a bipolar cauterizer or place the indifferent electrode as far from the device as possible. Lithotripsy. Do not focus a lithotripsy beam within 16 cm of the device. Program the device to
Download User's Manual - SJM
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Allure™, Allure™ RF, Allure Quadra™, Allure Quadra™ RF ...
manuals.sjm.comTesting has demonstrated that the St. Jude Medical™ MR Conditional pacing system is conditionally safe for use in the MRI environment when used according to the instructions in the MRI Procedure Information document. The St. Jude Medical MR Conditional pacing system includes a St. Jude Medical MR Conditional pulse generator
MRI-Ready Systems Manual - St. Jude Medical Instructions ...
manuals.sjm.comThe St. Jude Medical MR Conditional system includes a St. Jude Medical MR Conditional device connected to one or more St. Jude Medical MR Conditional leads. For a list of the device/lead combinations that have been tested, see the device/lead combinations tables (page . …
MRI Procedure Information - SJM
manuals.sjm.comuse this information to review the following requirements carefully because different device-lead combinations have different scanning restrictions. NOTE: For information about the MRI equipment that will be used to scan the patient, including important safety
Information, Important, Carefully, Because, Carefully because
Tendril STS 2088 [OUS] - St. Jude Medical Instructions for ...
manuals.sjm.com1. Inside sterile field : Sterilization The package contents have been sterilized with ethylene oxide before shipment. This lead is for single use only and is not intended to be resterilized. If the sterile package has been compromised, contact St. Jude Medical. Implanting the Tendril™ STS Lead : Pre-Implantation : Before implanting the lead:
User's Manual - St. Jude Medical Instructions for Use Website
manuals.sjm.comThe device and the incision and insertion tools have been sterilized with ethylene oxide prior to shipment. They are intended for single use only and should not be resterilized. If the sterile package has been compromised, contact St. Jude Medical. Do not insert the device if the dot on the ethylene oxide label is purple.
Devices, Medical, Sterile, Packages, Jude, Jude medical, Sterile package
User's Guide - SJM
manuals.sjm.comThe St. Jude Medical™ Patient Controller app is intended to be used with the generator to help the patient manage prescribed stimulation programs. Indications for Use . This neurostimulation system is indicated as an aid in the management of chronic, intractable pain of the trunk and/or limbs, including unilateral or bilateral
Ellipse Fortify Assura - SJM
manuals.sjm.comAdditional pacemaker implanted. These devices provide bradycardia pacing. If another pacemaker is used, it should have a bipolar pacing reset mode and be programmed for bipolar pacing to minimize the pos sibility of the output pulses being detected by the device. Modifying the device. This device has been tested for compliance to FCC regulations.
MRI-Ready Systems Manual - SJM
manuals.sjm.coman MRI scanner when used according to the instructions in this manual. CAUTION Not all of the products listed as MR Conditional are approved for MR Conditional use in all countries or regions. Before performing an MRI scan on patients implanted with …
MRI Ready Monitor Systems Manual - SJM
manuals.sjm.comDuring the MRI scan, visually and audibly monitor the patient, including verbal communication. The following potential effects during the scan should be considered: When selecting the field of view and imaging parameters, consider that image distortion may occur around the ICM. Consider these factors also when interpreting the MRI images.
Merlin@home Transmitter [RF] [symbol update] [RED ... - SJM
manuals.sjm.com3 all right, carefully repackage the transmitter in its original packaging. If you are using a telephone with your Merlin@home transmitter, you may want to …
Related documents
Principles of Electrosurgery - Association of Surgeons in ...
www.asit.orgelectrosurgery, the active electrode is in the surgical site. The patient return electrode is somewhere else on the patient’s body. The current passes through the patient as it completes the circuit from the active electrode to the patient return electrode.
Allure™, Allure™ RF, Allure Quadra™, Allure Quadra™ RF ...
manuals.sjm.comElectrosurgery. Do not use electrosurgical devices in the vicinity of an implanted device. If electrocautery is necessary, use a bipolar cauterizer or place the indifferent electrode as far from the device as possible. Lithotripsy. Do not focus a lithotripsy beam within 16 cm of the device. Program the device to
Revised January 2013 Revised July 2014 Introduction
www.ast.orgelectrosurgery within the sterile field. A. Surgery personnel should wear flame-resistant gowns when performing laser surgery. B. Surgery personnel should still exercise caution when wearing any type of gown, including flame-resistant gowns. Gown material is composed of natural and/or synthetic fibers that could be flammable. If the three
Prepublication Requirements
www.jointcommission.orgelectrosurgery, cautery, lasers, or other ignition sources, the hospital performs an annual fire drill in anesthetizing locations. The drill may be announced or unannounced, The drill addresses extinguishment of the patient, drapery, clothing, and equipment. (For full text, refer to NFPA 99-2012: 15.13.3.9; 15.13.3.10)