Vertical Installation Technical Specification
External walls constructed as per this technical specification using Linea Oblique Weatherboard and bulk insulation, where the area of glazing is 30% or less of the total wall area, complies with the insulation requirements for walls in the NZBC Acceptable Solution H1/AS1 (Energy Efficiency Clause H1), Table 1.
Specification, Technical, External, Technical specifications
Download Vertical Installation Technical Specification
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Technical Specification - jameshardie.co.nz
www.jameshardie.co.nzLinea® Weatherboard Technical Specification April 2016 New Zealand 3 1 Application and scope 1.1 APPLICATION Linea® Weatherboard is …
Design Manual - jameshardie.co.nz
www.jameshardie.co.nzFire and Acoustic Design Manual August 2017 New Zealand 3 1 Introduction readers are familiar with the relevant James Hardie cladding and lining product literature.
Design Manual - James Hardie
www.jameshardie.co.nzFigure 1: Vertical junction between Linea™ Weatherboard and James Hardie flat sheet cladding Figure 2: Vertical junction between Linea™ Weatherboard and James Hardie flat sheet cladding 4 James Hardie Cladding Junction Details Design Manual November 2016 New Zealand Flexible underlay Linea™ Weatherboard Scriber 60 x 3.15mm jolt head
Fire & Acoustic - James Hardie
www.jameshardie.co.nz3.1 External Walls - Timber Frame 8 3.2 External Walls - Steel Frame 10 3.3 Parapet & Wing Walls ... S - StriaTM Cladding ... Refer to recommended safe working practices in each specific product technical specification or installation manual
Specification, Technical, External, Technical specifications, Cladding
CLD Structural Cavity Batten Technical Specification
www.jameshardie.co.nzThis specification covers the use of Titan Façade Panel on buildings, where the maximum wind pressure exerted on the building façade is up to 2.5kPa (ULS). This specification is intended for use by architects or designers/ specifier and installers who …
Specification, Technical, Pressure, Technical specifications
Design Manual - James Hardie
www.jameshardie.co.nzThe specifier or other party responsible for the project must run through a risk matrix analysis as per E2/AS1 to determine which construction method is applicable to install the external cladding on the project. The designer must also ensure that the bracing capacities published in this specification are appropriate for the intended application.
Manual, Applications, Design, Risks, Construction, Design manual
jameshardie.co.nz CLD Structural Cavity Batten
www.jameshardie.co.nzPortland cement, ground sand, cellulose fibre and water. The product is easily identified by the name 'Stria Cladding' printed on the back of the panels. CLD Structural Cavity Batten is manufactured using a low density fibre cement formulation. The basic composition is Portland cement, ground sand, cellulose fibre, water and proprietary additives.
Structural, Cement, Cld structural cavity batten, Cavity, Batten, Portland, Portland cement
Related documents
CORRUGATE - Roof
www.roof.co.nzWall Cladding Application Fix in the pan adjacent to every side lap over rib and every 2nd pan, and at all external and internal corners. (No metal washer required) Wall Cladding Wind Load Span Pan fixed wall cladding can be assumed to have a wind load design at least equivalent to C1L from the above graphs.
20’ TANK CONTAINER STANDARD SPECIFICATION MODEL …
www.tankspan.comExternal Welds & Heat marks Passivation Internal Yes External Spillboxes only Anti-stress lacquer Whole exterior of tank including skirts 3.10 Insulation and Cladding Material Mineral Wool Polyurethane Shell 30 mm (min 60kg/m_) 20 mm (min 35kg/m_) Ends varies (min 60kg/m_) Cladding 0,8mm thick pre painted aluminium (Grade Alloy 3004 H32) or ...
SHADOWCLAD SPECIFICATION & INSTALLATION GUIDE
chhply.co.nzcurrent specification material and any relevant technical notes. For buildings containing mixed cladding solutions with Shadowclad refer Shadowclad Specification and Installation Guide for mixed cladding systems on cavity construction. 1.2 PRODUCT DESCRIPTION & RANGE Shadowclad structural plywood panels are manufactured from radiata pine wood ...
Guide, Installation, Specification, Technical, Cladding, Specification amp installation guide
Axon Cladding Installation Guide
static-content-prod.jameshardie-digital.com.aucladding, at internal corner junctions to conceal the board edge. 5 per pack. Part No. 305520 James Hardie™ 9mm Aluminium External A ready to paint aluminium extrusion, to be used with EasyLap™ panel and Scyon™ Axon™ cladding, at external corner junctions to conceal the board edge. 5 per pack. Part No. 305521 James Hardie™ 75x75mm ...
Best Practice Guide External Wall Insulation
www.inca-ltd.org.ukInsulated Render and Cladding Association 6-8 Bonhill Street London EC2A 4BX. Endorsements This guide has been endorsed by the European Association for External Thermal Insulation Composite Systems (EAE). Acknowledgments This guidance has been produced by the INCA Technical Committee. INCA would like to thank the following contributors:
Guide, Practices, Technical, Walls, Insulation, External, Cladding, Practice guide external wall insulation
Fire & Acoustic - James Hardie
www.jameshardie.co.nz3.1 External Walls - Timber Frame 8 3.2 External Walls - Steel Frame 10 3.3 Parapet & Wing Walls ... S - StriaTM Cladding ... Refer to recommended safe working practices in each specific product technical specification or installation manual
Specification, Technical, External, Technical specifications, Cladding
Composite Roof And Wall Cladding Panel Design Guide
www.mcrma.co.ukComposite cladding panels consist of pre-coated external and internal metal facings which are bonded to a rigid insulation core. 2.1 Facings. Composite cladding panels have facings made of steel to BSEN 10147 or aluminium to BS 1470. Thicknesses vary from product to product depending on application but the following are generally regarded as ...
NBS - Reference Specification - SE Controls
www.secontrols.comA90€GENERAL TECHNICAL REQUIREMENTS GENERAL Precedence General: Where, and to the extent that, documents conflict the following orders of precedence apply: • €Schedules of work override preliminaries, which override contract drawings, which override the Reference specification. • €Work sections of the Reference specification override A90.
Regulation 7(2), Regulation 7(3) and Requirement B4 ...
www.wintech-group.comAbout the Centre for Window and Cladding Technology (CWCT) The Centre for Window and Cladding Technology (CWCT) is a publisher of industry standards and guidance on building envelopes. CWCT provides training for many people involved in the design, specification, and construction of building envelopes. Founded in 1989 it is now supported by over