Example: tourism industry

LOCKNETICS PAGES new7/27 - mfsales.com

93 LOCKNETICSH eavy Duty Electric Strikes9000 Series PowerStrikeThe new 9000 Series PowerStrikeprovides the mostuniversal, heavyduty electric strikeavailable in themarketplace is designed toaccommodate virtu-ally all cylindrical and mortise include a cast stainless steelhousing, field selectable voltage12/24 VDC, modular fail safe or fail securesolenoids, four modular monitoringswitches, horizontal adjustment for weath-erstripping, and one frame prep whichaccepts a variety of mortise locksets withdifferent latchbolt and deadbolt frame prep The design of the9000 PowerStrike accepts virtually allcommercial grade cylindrical and mor-tise locksets with one frame design accepts a variety ofmortise locksets with different latch-bolt and deadbolt locations. Modularface plates are provided for differentfunction voltage, modular solenoid Thesolenoid can accept 12 and 24 VDCinput, which is field adjustment The strike isprovided with two sets of mountingholes to allow horizontal alternate mounting position pro-vides a 3/16 adjustment to accommo-date weatherstripping and : nStrike cavity: Depth 1 ,Width 13/16 ,Height 1-11/16 nCurrent Draw: Dual Voltage,Field Amp @ 12 VDC Amp @ 24 VDCHow to Order the 9000 Series:Example1.

9010 Cylindrical Locksets Operation:After releasing the latch-bolt the keeper returns to the locked position. 9020, 9020SYS Mortise locksets and mortise panic

Tags:

  Pages, Locknetics pages new7 27, Locknetics, New7

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of LOCKNETICS PAGES new7/27 - mfsales.com

1 93 LOCKNETICSH eavy Duty Electric Strikes9000 Series PowerStrikeThe new 9000 Series PowerStrikeprovides the mostuniversal, heavyduty electric strikeavailable in themarketplace is designed toaccommodate virtu-ally all cylindrical and mortise include a cast stainless steelhousing, field selectable voltage12/24 VDC, modular fail safe or fail securesolenoids, four modular monitoringswitches, horizontal adjustment for weath-erstripping, and one frame prep whichaccepts a variety of mortise locksets withdifferent latchbolt and deadbolt frame prep The design of the9000 PowerStrike accepts virtually allcommercial grade cylindrical and mor-tise locksets with one frame design accepts a variety ofmortise locksets with different latch-bolt and deadbolt locations. Modularface plates are provided for differentfunction voltage, modular solenoid Thesolenoid can accept 12 and 24 VDCinput, which is field adjustment The strike isprovided with two sets of mountingholes to allow horizontal alternate mounting position pro-vides a 3/16 adjustment to accommo-date weatherstripping and : nStrike cavity: Depth 1 ,Width 13/16 ,Height 1-11/16 nCurrent Draw: Dual Voltage,Field Amp @ 12 VDC Amp @ 24 VDCHow to Order the 9000 Series:Example1.

2 Select Model 9010 2. Select Operation 9010-FSFail Secure (standard)-no symbol required Fail Safe (optional)-specify FS3. Select Finish9010-FS-6304. Select Options9010-FS-630-LPSS trike Model Selection Chart by Manufacturer9030,9030 SCH 9030 YSA 90409040 SCH 9040 YSA9010 90209020 SYS90509050 SCH9050 YSAA ccuratennArrownnnBaldwinnnBestnnnCorbin RusswinnnnFalconnnnMarksnnnOmniannPDQnnn Sargentnn*n*nSchlagennnYalennn*Note: Use 9020 SYS for the Sargent 8100 series and 9020 for the 8200 models are used for most modular fronts are used for different suffix model is used for Schlage,Yale and Sargent mortise locksets - with latchboltSCH suffix model is used for Schlage mortise locksets with deadboltYSA suffix models are used for Yale and Sargent with deadboltLock OptionsFSFail Safe locked when energized BPS*Bolt Position Switch monitors position of deadbolt (not available on model 9050)LPS*Latch Position Switch monitors position of latchbolt (not available on model 9040)

3 KPSK eeper Position Switch monitors position of keeper SPSS olenoid Position Switch monitors position of solenoid RCPR ectifier for AC operation*specify hand when ordering LPS and/or BPS for mortise locksetsLock FinishStainless Steel Keeper and Frame are finished Stainless for 630 and 626 finishes and blackfor other finishes. Strike front is provided in architectural finish listed Stainless Steel630US32 DBright Brass 605US3 Satin Brass 606US4 Satin Bronze 612US10 ANSI Bronze613US10 BBright Chrome625US26 Satin Chrome626US26D9010 Cylindrical LocksetsOperation:After releasing the latch-bolt the keeper returns to the , 9020 SYS Mortise locksets and mortise panicexit devices, with or without a deadlatchOperation:After releasing the latchbolt the keeper returns to thelocked , 9030 SCH, 9030 YSA Mortise locksets where the deadboltis used for night latch function onlyOperation: Latchbolt released elec-tronically during traffic manually extended at nightfor added security.

4 Deadbolt may bereleased electrically but the door will not return to the , 9040 SCH, 9040 YSA Mortise locksets with a normallyextended 1 deadbolt where lockset isreleased, recaptured and containedOperation: Both latchbolt and dead-bolt are released by a single is held open after release so that door may be closedwith deadbolt extended. Keeper returns to locked conditionwhen bolt re-enters the , 9050 SCH, 9050 YSA Mortise locksets where the deadboltis not releasedOperation:When the deadbolt is projected manually the strike will the deadbolt is retracted access is accomplished byelectrically releasing the Series TouchbarThe 671 Touchbar is a non-latchingelectromechanical releasing devicewhich allows egress at doorsequipped with electric the 671 Touchbar at anypoint on the bar activates an internal switch which controlspower to the locking touchbar pressure at any point on bar activates internal switchwhich releases locking 1/4 movement of bar to activate Duty aluminum extrusion nSPDT Monitoring Size: 36, 42 or 48 - standard sizes SP (special - specifyframe opening as shown below) nFinish.

5 628 - Clear Anodized Aluminum (standard) 313 - Dark Satin Bronze Anodized AluminumMechanical nAvailable in standard lengths to fit 36 , 42 and 48 lengths for up to 48 doors also also be field cut at the installation Switch nSPDT contacts rated 5A @ 125 VAC (3A @ 30 VDC) nLeads: (3) 20 AWG 18 LongOption Switch nDPDT contacts rated 5A @ 125 VAC (3A @ 30 VDC) nLeads: (6) 20 AWG 18 LongOptionsnDP - Double pole, double throw switch nCA - 16 foot cable, attached to device nAR - 16 inch armored door cord (no wire) nAW - 16 inch armored door cord with 24 wire,4 conductor 20 AWG nWD - Wood Door Kit - thru bolts (rivnuts standard)Standard size TouchBar furnished for door framewith 1/4 stop (B) Specify frame opening - (A) , 671SP - 4394 LOCKNETICSH eavy Duty Electric Strikes/Exit DevicesToll Free: (800) 221-2052 nPhone: (718) 622-8785 or (516) 352-6262 nFax: (718) 789-8346 ne-mail: cord671barTypical InstallationABNote: Use 9020 SYS for theSargent 8100 series and 9020 for the 8200 Alarms690 Series SmartBarExit Releasing DeviceThe 690 Series SmartBar is an electronic switching device withno moving parts, which serves as a non-latching exit bar at anegress door.

6 It allows one motion egress at doors equipped withelectric or electronic locks, with no prior knowledge requiredby the the SmartBar at any point on the bar acti-vates internal circuitry which controls power to the SmartBar provides redundant detection systems tosense an exit first is a capacitance touch sense cir-cuit which detects a change in capacitance when a persontouches the metal portion of the second is an infraredlight beam which is directed across the front of the bar. Eitherthe capacitance or light beam detection will activate the patented redundant system provides a high level of life safe-ty and peace of mind to the end user. An optional audible alarmis feature provides a security alarm to alert whenthere is a prolonged unlocked condition caused by a continuedcapacitance signal or a continued break in the light Design. No moving Duty aluminum monitoring Cord and 16 ft.

7 Cable Size: 36, 42 or 48 - standard (special - specify frame opening)nFinish: 628 - Clear Anodized Aluminum (standard) 313 - Dark Satin Bronze Anodized AluminumSpecificationsMechanical nAvailable in standard lengths to fit 36 , 42 and 48 lengths for up to 48 doors also also be field cut at the installation nInput: 12 or 24 VAC/DC. Maximum current draw .250 : SPDT contacts rated 3A @ 30 : 9 Conductor Cable - 24 AWG - 16 ft. long (7 conductors used)OptionsnAUD - Audible Alarm nWD - Wood Door KitStandard size SmartBar furnished for door frame with 5/8 stopSpecify frame opening - , 690SP - Series SmartExitElectrified and Electronic Exit Devices SmartExitLocknetics introduces SmartExit an innovative family of elec-trified and electronic exit devices - designed, and manufacturedby LOCKNETICS . SmartExit features simplified mechanical designswith state-of-the-art electronic solutions, including on boardaccess control with outside lever trim.

8 All units feature lowpower consumption dual voltage or battery powered latching models are UL Listed for A label fire rated control with outside trim provides ability to programcodes or TouchEntry keys with users, toggle, lockout, one timeuser, and double reader built into bar provides6010 DEL Delayed Egress with ability to release or reset and6010 EDG Electronic Dogging with ability to dog withTouchEntry access control system also provides the abil-ity to program 150 users and retrieve the 100 event audit the MX500 option 500 user and 500 eventaudit trail is : nNon-handed rim exit device, easy to cut in field with 3 standard sizes: 36 , 42 & 48 nAutomatic Voltage Selection: 12 or 24 VDC nFewer moving parts, investment cast stainless steel latchbolt& deadlocking Series continued on following DevicesToll Free: (800) 221-2052 nPhone: (718) 622-8785 or (516) 352-6262 nFax: (718) 789-8346 ne-mail: Series SmartExitElectrified and Electronic Exit Devices Modelsn6010 DEL Delayed Egress (Current Draw: @ 12 VDC or @ 24 VDC).

9 15 or 30 second delay and audible alarm upon unauthorized Electronic Unlocking Hardwired (Current Draw: @ 12 VDC or 24 VDC).Free egress with LOCKNETICS SelectEntry or TouchEntry progammable access Electronic Unlocking Battery Operated (4 AA Batteries) No wiring egress with LOCKNETICS SelectEntry or TouchEntry programmable access Basic Access Control Electric Unlocking (Current Draw: @ 12 or @ 24 VDC).Free egress with universal access control input. Use accesscontrol device with DPDT contact. Use FLL (Fail Locked) forPerimeter Access Control or FUL (Fail Unlocked) forStairwell Electrified Basic Dogging (Current Draw: @ 12 VDC or @ 24 VDC).After activation of dogging feature with control input, thefirst push on bar locks down push pad and retracts alarm or remote control releases bar and Electronic Dogging (Current Draw: @ 12 VDC or @ 24 VDC).

10 After activation of dogging feature with TouchEntry key orother signal, the first push on bar locks down push pad andretracts latch and unlocks outside trim. Fire alarm returnsdevice to latched position. SEL and TEL trims are unaffectedby fire Request to Exit Switch DPDT Latching exit device with push pad monitoring switch foractivation of other Request to Exit Switch DPDT Non-latching exit bar with push pad monitoring switch foractivation of other Access Control with Outside TrimnSEL: SelectEntry Lever Trim includes both programmable keypad and TouchEntry data key reader with emergencymechanical key :TouchEntry Lever Trim includes programmableTouchEntry data key reader with emergency mechanical key Access Control with Outside Trim (con t.)nMEL: Mechanical Entry Lever Trim mechanical lever trimwith mechanical : Universal Access Control Trim Fail trim for use with any DPDT access control Access Control.


Related search queries