Example: bachelor of science

NI PXIe-4080/4081/4082 Getting Started Guide - …

Getting Started GUIDENI PXIe-4080/4081 MS/s digital MultimeterNote Before you begin, install and configure your chassis and document explains how to install, configure, and test the NI 4080/4081/4082. TheNI 4080/4081/4082 is a digital multimeter that ships with NI-DMM, which you use toprogram the access NI 4080/4081/4082 documentation, navigate to Start All Programs NationalInstruments NI-DMM The protection provided by this device may be impaired if the device isused in a manner not specified in this Compatibility the System the the 3 Kit the the NI 4080/4081 Front Panel 7 Requirements for Cables and the NI 4080/4081/4082 in the NI 4080/4081 14 What Should I Do if the NI 4080/4081/4082 Doesn't Appear in MAX?..14 What Should I Do if the Module Fails the Self-Test?..15 Where to Go Support and Compatibility GuidelinesThis product was tested and complies with the regulatory requirements and limits forelectromagnetic compatibility (EMC) stated in the product specifications.

GETTING STARTED GUIDE NI PXIe-4080/4081/4082 1.8 MS/s Digital Multimeter Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI 4080/4081/4082.

Tags:

  4800, Digital, 2480, 1048, Ipex, Ni pxie 4080 4081 4082

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of NI PXIe-4080/4081/4082 Getting Started Guide - …

1 Getting Started GUIDENI PXIe-4080/4081 MS/s digital MultimeterNote Before you begin, install and configure your chassis and document explains how to install, configure, and test the NI 4080/4081/4082. TheNI 4080/4081/4082 is a digital multimeter that ships with NI-DMM, which you use toprogram the access NI 4080/4081/4082 documentation, navigate to Start All Programs NationalInstruments NI-DMM The protection provided by this device may be impaired if the device isused in a manner not specified in this Compatibility the System the the 3 Kit the the NI 4080/4081 Front Panel 7 Requirements for Cables and the NI 4080/4081/4082 in the NI 4080/4081 14 What Should I Do if the NI 4080/4081/4082 Doesn't Appear in MAX?..14 What Should I Do if the Module Fails the Self-Test?..15 Where to Go Support and Compatibility GuidelinesThis product was tested and complies with the regulatory requirements and limits forelectromagnetic compatibility (EMC) stated in the product specifications.

2 These requirementsand limits provide reasonable protection against harmful interference when the product isoperated in the intended operational electromagnetic product is intended for use in industrial locations. However, harmful interference mayoccur in some installations, when the product is connected to a peripheral device or test object,or if the product is used in residential or commercial areas. To minimize interference withradio and television reception and prevent unacceptable performance degradation, install anduse this product in strict accordance with the instructions in the product , any changes or modifications to the product not expressly approved by NationalInstruments could void your authority to operate it under your local regulatory the System RequirementsTo use the NI 4080/4081/4082, your system must meet certain requirements.

3 For moreinformation about minimum system requirements, recommended system, and supportedapplication development environments (ADEs), refer to the readme, which is available on thesoftware media or online at the KitCaution To prevent electrostatic discharge (ESD) from damaging the device,ground yourself using a grounding strap or by holding a grounded object, such asyour computer Touch the antistatic package to a metal part of the computer Remove the device from the package and inspect the device for loose components or anyother sign of Never touch the exposed pins of Do not install a device if it appears damaged in any Unpack any other items and documentation from the the device in the antistatic package when the device is not in | | NI PXIe-4080/4081/4082 Getting Started GuidePreparing the EnvironmentEnsure that the environment you are using the NI 4080/4081/4082 in meets the EnvironmentAmbient temperature range0 C to 55 C (Tested in accordance withIEC 60068-2-1 and IEC 60068-2-2.)

4 MeetsMIL-PRF-28800F Class 3 low temperaturelimit and MIL-PRF-28800F Class 2 hightemperature limit.)Relative humidity range10% to 90%, noncondensing (Tested inaccordance with IEC 60068-2-56.)Storage ambient temperature range-40 C to 70 C (Tested in accordancewith IEC 60068-2-1 and IEC 60068-2-2.)Maximum altitude2,000 m (800 mbar) (at 25 C ambienttemperature)Pollution Degree2 Indoor use Refer to the device specifications on for Always refer to the specifications document for your device beforeconnecting signals. Failure to observe the specified maximum signal ratings cancause shock, a fire hazard, or damage to the devices connected to theNI 4080/4081/4082. NI is not liable for any damage or injuries resulting fromincorrect signal PXIe-4080/4081/4082 Getting Started Guide | National Instruments | 3 Kit ContentsFigure 1. NI 4080/4081/4082 Kit Contents4532 PXIe-408061/2 Digit DMM11.

5 NI PXIe-4080/4081/4082 Device2. Test probes3. Driver Software DVD4. NI PXIe-4080/4081/4082 Getting Started Guide (this document)5. Maintain Forced-Air Cooling Note to UsersOther EquipmentThere are several required items not included in your device kit that you need to install oroperate the NI 4080/4081/4082. 1/8 in. flathead screwdriver A PXI Express chassis with a controller and the chassis documentationInstalling the SoftwareYou must be an Administrator to install NI software on your Install an ADE, such as LabVIEW or LabWindows /CVI .2. Insert the driver software media into your computer. The installer should the installation window does not appear, navigate to the drive, double-click it, anddouble-click Follow the instructions in the installation Windows users may see access and security messages duringinstallation.

6 Accept the prompts to complete the | | NI PXIe-4080/4081/4082 Getting Started Guide4. When the installer completes, select Restart in the dialog box that prompts you to restart,shut down, or restart the NI 4080/4081/4082 Caution To prevent damage to the NI 4080/4081/4082 caused by ESD orcontamination, handle the module using the edges or the metal Ensure the AC power source is connected to the chassis before installing the AC power cord grounds the chassis and protects it from electrical damage while youinstall the Power off the Inspect the slot pins on the chassis backplane for any bends or damage prior toinstallation. Do not install a module if the backplane is Remove the black plastic covers from all the captive screws on the module front Identify a supported slot in the chassis. The following figure shows the symbols thatindicate the slot 2.

7 Chassis Compatibility SymbolsNI PXIe-1062Q123451. PXI Express System Controller Slot2. PXI Peripheral Slot3. PXI Express Hybrid Peripheral Slot4. PXI Express System Timing Slot5. PXI Express Peripheral SlotNI 4080/4081/4082 modules can be placed in PXI Express peripheral slots, PXI Expresshybrid peripheral slots, or PXI Express system timing Touch any metal part of the chassis to discharge static Ensure that the ejector handle is in the downward (unlatched) Place the module edges into the module guides at the top and bottom of the chassis. Slidethe module into the slot until it is fully PXIe-4080/4081/4082 Getting Started Guide | National Instruments | 5 Figure 3. Module Installation23NI PXIe-107511. Chassis2. Hardware Module3. Ejector Handle in Downward (Unlatched) Position9. Latch the module in place by pulling up on the ejector Secure the module front panel to the chassis using the front-panel mounting Tightening the top and bottom mounting screws increases mechanicalstability and also electrically connects the front panel to the chassis, which canimprove the signal quality and electromagnetic Cover all empty slots using EMC filler panels or fill using slot blockers to maximizecooling air flow, depending on your Power on the Front Panel ConnectorsRefer to the following figure for the NI 4080/4081/4082 front panels.

8 The front panels havefour shrouded banana plug | | NI PXIe-4080/4081/4082 Getting Started GuidePXIe-40806 -Digit DMMPXIe-40817 -Digit DMMPXIe-40826 -Digit DMMHIHILOLOHIHILOLOHIHILOLO300 V300 V CAT II300 V CAT II500 V CAT II1000 V CAT I 4 W V INPUT V INPUT V INPUTMAX500 VMAX300 VMAXMAXAMPSAMPSAMPSSENSE1A 4 W MAXSENSE1A 4 W MAXSENSE3 AMAX300 VMAX1k VMAX300 VConnecting SignalsThe following figures show how to connect signals to the DMM front panel connectors forcommon more information about these common measurements, refer to the NI digital MultimetersHelp at Always refer to the device specifications before connecting to observe the specified maximum signal ratings can cause shock, a fireNI PXIe-4080/4081/4082 Getting Started Guide | National Instruments | 7hazard, or damage to the devices connected to the DMM. NI is not liable for anydamage or injuries resulting from incorrect signal 4.

9 DC and AC VoltageorACDCHILOHILOF igure 5. DC and AC CurrentHILOHILO8 | | NI PXIe-4080/4081/4082 Getting Started GuideFigure 6. 2-Wire and 4-Wire ResistanceHILOHILOHILOHILONote 4-wire resistance measurements use both pairs of terminals. Use theconfiguration to measure low resistances accurately by eliminating the effects oflead 7. Capacitance and Inductance+ HILOHILOHILOHILONI PXIe-4080/4081/4082 Getting Started Guide | National Instruments | 9 Figure 8. Voltage Drop Across a Diode+ HILOHILOR equirements for Cables and ProbesThe DMM shipping kit contains a pair of test probes with safety banana plugs. These probesmeet international safety requirements, including UL 3111 and IEC-1010-1, for the full rangeof applications supported by the Before using any probes or accessories, ensure that they meet applicablesafety requirements for the signal levels you may the test probes to the banana plug connectors on the DMM front panel using safetybanana plugs.

10 The shrouds around the banana plugs prevent you from contacting potentiallyhazardous voltages connected to the test probes. You can also connect the cable to standard,unshrouded banana plug probes or accessories. Use unshrouded probes or accessories onlywhen the voltages are less than 30 Vrms and 42 Vpk, or 60 (NI 4081 users) To prevent possible safety hazards, the maximum voltagebetween any of the inputs and the ground of the PXI Express chassis is 500 VDC or500 Vrms (sine wave), except between the HI terminal and ground, where themaximum voltage is 1,000 VDC or700 Vrms (sine wave). The maximum current theNI 4081 can measure through the current inputs is 3 ADC or 3 (NI 4080/4082 users) To prevent possible safety hazards, the maximumvoltage between any of the inputs and the ground of the computer is 300 VDC or300 Vrms. The maximum current the NI 4080/4082 can measure through the currentinputs is 1 ADC or 1 | | NI PXIe-4080/4081/4082 Getting Started GuideConfiguring the NI 4080/4081/4082 in MAXUse Measurement & Automation Explorer (MAX) to configure your NI hardware.