Example: stock market

NI cRIO-9030 Specifications - National Instruments

SPECIFICATIONSNI cRIO-9030 Embedded CompactRIO Controller with Real-Time Processor andReconfigurable FPGAThis document lists the Specifications for the National Instruments cRIO-9030 . The followingspecifications are typical for the -20 C to 55 C operating temperature range unless Do not operate the cRIO-9030 in a manner not specified in this misuse can result in a hazard. You can compromise the safety protectionbuilt into the product if the product is damaged in any way. If the product isdamaged, return it to NI for Atom E3825 Number of cores2 CPU GHzOn-die L2 cache1 MB (shared)Operating SystemNote For minimum software support information, visit and enter theInfo Code operating systemNI Linux Real-Time (64-bit)Software requirementsApplication softwareLabVIEWLabVIEW 2014 or later,LabVIEW Real-Time Module 2014 or later,LabVIEW FPGA Module 2014 or later1,C/C++ Development Tools for NILinux R

SPECIFICATIONS NI cRIO-9030 Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA This document lists the specifications for the National Instruments cRIO-9030.

Tags:

  Specification, National, Instruments, National instruments

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NI cRIO-9030 Specifications - National Instruments

1 SPECIFICATIONSNI cRIO-9030 Embedded CompactRIO Controller with Real-Time Processor andReconfigurable FPGAThis document lists the Specifications for the National Instruments cRIO-9030 . The followingspecifications are typical for the -20 C to 55 C operating temperature range unless Do not operate the cRIO-9030 in a manner not specified in this misuse can result in a hazard. You can compromise the safety protectionbuilt into the product if the product is damaged in any way. If the product isdamaged, return it to NI for Atom E3825 Number of cores2 CPU GHzOn-die L2 cache1 MB (shared)Operating SystemNote For minimum software support information, visit and enter theInfo Code operating systemNI Linux Real-Time (64-bit)

2 Software requirementsApplication softwareLabVIEWLabVIEW 2014 or later,LabVIEW Real-Time Module 2014 or later,LabVIEW FPGA Module 2014 or later1,C/C++ Development Tools for NILinux Real-Time2 Eclipse Edition 2014 or laterDriver softwareNI-RIO Device Drivers August 2014 or laterNetwork/Ethernet PortNumber of ports2 Network interface10 Base-T, 100 Base-TX, and1000 Base-T EthernetCompatibilityIEEE rates10 Mbps, 100 Mbps, 1000 Mbpsauto-negotiatedMaximum cabling distance100 m/segmentRS-232 Serial PortMaximum baud rate115,200 bpsData bits5, 6, 7, 8 Stop bits1, 2 ParityOdd, Even, Mark, SpaceFlow controlRTS/CTS, XON/XOFF, DTR/DSRRI wake maximum low VRI wake minimum high VRI overvoltage tolerance 24 V1 LabVIEW FPGA Module is not required when using Scan Interface mode.

3 To program the user-accessible FPGA on the cRIO-9030 , LabVIEW FPGA Module is ++ Development Tools for NI Linux Real-Time is an optional interface for C/C++programming of the cRIO-9030 processor. Visit and enter Info Code RIOCdev formore information about the C/C++ Development Tools for NI Linux | | NI cRIO-9030 SpecificationsRS-485/422 (DTE) Serial PortMaximum baud rate115,200 bpsData bits5, 6, 7, 8 Stop bits1, 2 ParityOdd, Even, Mark, SpaceFlow controlXON/XOFFWire mode4-wire, 2-wire, 2-wire autoIsolation voltage60 VDC continuous, port to earth groundNote The RS-485 serial port ground and shield are not connected to chassisground.

4 This isolation is intended to prevent ground loops and does not meet ULratings for safety requirementUnshielded, 30 m maximum length (limited byEMC/surge)Note RS-485 is capable of km (4,000 ft) length without surge PortsNumber of portsDevice ports1 standard B connectorHost ports2 standard A connectorsNote The USB device port is intended for use in device configuration, applicationdeployment, debugging, and interfaceUSB , Hi-SpeedMaximum data rate480 Mb/s per portMaximum current (USB host ports)1 A (aggregate)Mini DisplayPortMaximum resolution2560 1600 at 60 HzNI cRIO-9030 Specifications | National Instruments | 3SD Card SlotSD card supportSD and SDHC standardsMemoryNonvolatile3SD removable (user supplied)

5 Up to 32 GBSolid-state drive4 GBNote Visit and enter the Info Code ssdbp for information about thelife span of the nonvolatile memory and about best practices for using memoryDensity1 GBTypeDDR3 LMaximum theoretical data GB/sData throughputSystem memory to SD removablestorage410 MB/sModule slots to system memory20 MB/s, application- and system-dependentReconfigurable FPGAFPGA typeXilinx Kintex-7 7K70 TNumber of flip-flops82,000 Number of 6-input LUTs41,000 Number of DSP slices (18 25 multipliers)240 Available block RAM4,860 kbitsNumber of DMA channels16 Number of logical interrupts3231 MB is equal to 1 million bytes.

6 1 GB is equal to 1 billion bytes. The actual formatted capacitymight be the manufacturer Specifications of your SD removable | | NI cRIO-9030 SpecificationsInternal Real-Time ClockAccuracy200 ppm; 40 ppm at 25 CCMOS BatteryTypical battery life with power applied topower connector10 yearsTypical battery life when stored attemperatures up to 25 yearsTypical battery life when stored attemperatures up to 85 yearsPower RequirementsNote Some C Series modules have additional power requirements. For moreinformation about C Series module power requirements, refer to the C Seriesmodule(s) input range (measured at the cRIO-9030 power connector)V19 V to 30 VV29 V to 30 VMaximum power consumption40 WNote The maximum power consumption specification is based on a fully populatedsystem running a high-stress application at elevated ambient temperature and withall C Series modules and USB devices consuming the maximum allowed standby power W at 24 VDC inputRecommended power supply100 W, 24 VDCT ypical leakage current from secondary power input (V2)

7 While system is powered fromprimary power input (V1)At 9 mAAt 30 mANI cRIO-9030 Specifications | National Instruments | 5 Caution Do not connect V2 to a DC mains supply or to any supply that requires aconnecting cable longer than 3 m (10 ft). A DC mains supply is a local DCelectricity supply network in the infrastructure of a site or ratings for inputs as described in IEC 61000V1 Short lines, long lines, and DC distributednetworksV2 Short lines onlyPower input connector4-position, mm pitch, pluggable screwterminal with screw locks,Sauro CTF04BV8-AN000 APhysical CharacteristicsIf you need to clean the cRIO-9030 , wipe it with a dry For two-dimensional drawings and three-dimensional models of thecRIO-9030, visit and search by module (unloaded)1,800 g (3 lbs, 15 oz)Dimensions (unloaded) mm mm mm( in.)

8 In. in.)Screw-terminal mm 2 to mm2 (20 AWG to 14 AWG)copper conductor wireWire strip length6 mm ( in.) of insulation stripped from theendTemperature rating85 CTorque for screw N m to N m ( lb in. lb in.)Wires per screw terminalOne wire per screw terminalConnector securementSecurement typeScrew flanges providedTorque for screw N m to N m ( lb in. lb in.)6 | | NI cRIO-9030 SpecificationsSafety VoltagesConnect only voltages that are below these terminal to C terminal30 VDC maximum, Measurement Category IV2 terminal to C terminal30 VDC maximum, Measurement Category IChassis ground to C terminal30 VDC maximum, Measurement Category IMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage.

9 MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesfrom specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and Do not connect the cRIO-9030 to signals or use for measurements withinMeasurement Categories II, III, or Measurement Categories CAT I and CAT O are equivalent. These test andmeasurement circuits are not intended for direct connection to the MAINS buildinginstallations of Measurement Categories CAT II, CAT III, or CAT (IEC-60068-2-1 and IEC-60068-2-2)Operating-20 C to 55 CStorage-40 C to 85 CCaution Failure to follow the mounting instructions in the user manual can causetemperature derating.

10 Visit and enter Info Code criomounting formore information about mounting configurations and temperature protectionIP20 Operating humidity (IEC 60068-2-56)10% RH to 90% RH, noncondensingStorage humidity (IEC 60068-2-56)5% RH to 95% RH, noncondensingPollution Degree (IEC 60664)2 Maximum altitude5,000 mIndoor use cRIO-9030 Specifications | National Instruments | 7 Hazardous (UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, AEx nA IIC T4 Canada (C-UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, Ex nA IIC T4 Europe (ATEX) and International (IECEx)Ex nA IIC T4 GcShock and VibrationTo meet these Specifications , you must mount the cRIO-9030 system directly on a flat, rigidsurface as described in the user manual, affix ferrules to the ends of the terminal wires, installan SD card cover (SD Door Kit, 783660-01), and use retention accessories for the USB hostports (NI Industrial USB Extender Cable, 152166-xx), USB device port (NI Locking USBC able, 157788-01), and mini DisplayPort connector (NI Retention Accessory for MiniDisplayPort, 156866-01).


Related search queries