Seismic Restraint
Found 10 free book(s)SMACNA Seismic Restraint Manual - iccsafe.org
media.iccsafe.orgThe third edition of the Seismic Restraint Manual was written to be compliant with IBC 2006 and ASCE 7-05. – The CBC 20071614A.1.14 ASCE 7 Section 13.6.7. » Modify ASCE 7 Section 13.6.7 by the following: Requirements of this section shall also apply for lp=1.5 – The IBC 2009 » 1613.6.8 HVAC ductwork with Ip = 1.5. Seismic supports
AWS D1.8 Seismic Supplement - Lincoln Electric
www.lincolnelectric.comHigh restraint Weak panel zones The report continued on to say “…additional conditions contributed significantly to the vulnerability of connections...” including: ... The primary focus of the AISC Seismic Provisions, however, is on the design of structures intended to resist seismically induced loads, including the design of the ...
Chapter 11 SEISMIC DESIGN CRITERIA - Memphis
www.ce.memphis.eduSEISMIC DESIGN CRITERIA 11.1 GENERAL 11.1.1 Purpose. Chapter 11 presents criteria for the design and construction of buildings and other structures subject to earth- ... rotational restraint to the top of the cantilevered element. JOINT: The geometric volume …
Fire Sprinkler Hanging & Bracing Products
www.erico.comSeismic Bracing Solutions ..... 4 Specifying a Trusted Solution – nVent CADDY Seismic Bracing Software..... 5 Building a Complete Solution with ... Restraint System, part of the line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1"
VA Standard Details - Div 23 HVAC Steam - All Details 1 of 2
www.cfm.va.govseismic separation assembly detail shown in nfpa 13 (sprinkler piping), utilizing flexible mechanical couplings, may be used in lieu of piping detail show above. ... adjust restraint to allow 1/4" [6 mm] movement of fan at start and stop. flexible duct connections fan discharge flexible duct connections fan inlet vibrators isolators
Chapter 11: Installing and Bracing Trusses
www.hansenpolebuildings.comlateral restraint) meet ANSI/TPI 1-2007 requirements as providing for permanent truss bracing to resist wind, seismic and other lateral forces (see GENERAL NOTES on building plans Sheet S-0). If a request is made to ADD to top or bottom chord continuous lateral
TOLCO seismic bracing - Eaton
www.eaton.comTOLCO seismic bracing products are manufactured in Reno, Nevada and the TOLCO seismic engineering team is located on the “Ring of Fire” in Fontana, California. Being located in a virtual “living laboratory of seismic activity” has driven our team of engineers to develop some . of the best seismic bracing product designs in the industry.
SEISMIC CEILING INSTALLATION - Armstrong Ceiling S
www.armstrongceilings.comThe seismic design category must be specified by a professional engineer or registered architect on the project drawings per ASCE 7. The project requirements which include the seismic design category can be found in Section 1 of the ... • Ceiling areas over 1,000 SF must have horizontal restraint wire or rigid bracing
Seismic Construction Handbook - Sound Concepts
www.soundconceptscan.comThe Seismic Design Category is determined from the following parameters: • The design force of the earthquake, which is ... without any perimeter restraint. Tempo-rary connections at the perimeter may be used as long as they are removed when construction is complete.
Shear Walls •Load Distribution to Shear Walls
efcms.engr.utk.eduNEHRP Seismic Design Technical Brief No. 9 Shear Walls 25 Example: Perforated Shear Wall Central pier carries about 85% of shear; can design for entire shear Good practice would be to add control joints 10’ 18’ 5’ 3’ 7’ 55’ 3’ 8’ 2’ 8’ 18’ 8’ 3’ 3’ 2’ 1. Need to provide prescriptive seismic reinforcement everywhere. 2.