Search results with tag "I stat"
PROCEDURE MANUAL FOR THE i-STAT SYSTEM - Lagaay
www.lagaay.comi-STAT cartridge is inserted into a handheld for analysis, the handheld automatically controls all functions of the testing cycle including fluid movement within the cartridge, calibration and continuous quality monitoring. A PCx Plus Glucose Test Strip is scanned and inserted into the i-STAT 1 Analyzer (Model Number 300) and a drop of
Frequently Asked Questions FAQs Abbott i-STAT
www.cms.govApr 29, 2020 · 2/28/2020 and 4/9/2020, respectively. With respect to the G3+ (BLUE) test cartridge, CMS is exercising enforcement discretion (as of 3/27/2020) to allow laboratories with a Certificate of Registration that applied for a Certificate of Compliance, or laboratories with a Certificate of Compliance, that have the i-STAT system, to use the
HEMATOCRIT/HCT AND CALCULATED HEMOGLOBIN/HB
www.abaxis.comanother cartridge. Intended Use The test for hematocrit, as part of the i-STAT® System, is intended for use in the in vitro quantification of packed red blood cell volume fraction in arterial, venous, or capillary whole blood. Hematocrit measurements can aid in the determination and monitoring of normal or abnormal total red
PCO2 AND CALCULATED VALUES FOR HCO3, TCO2, BASE …
harvardapparatus.comshould be retested using another cartridge. Intended Use The test for PCO2, as part of the i-STAT System, is intended for use in the in vitro quantification of carbon dioxide partial pressure in ar te ri al, venous, or capillary whole blood. Contents Each i-STAT cartridge contains one reference electrode (when potentiometric sensors are included
PO2 AND CALCULATED OXYGEN SATURATED
www.harvardapparatus.comanother cartridge. Intended Use The test for PO2, as part of the i-STAT System, is intended for use in the in vitro quantification of oxygen partial pressure in ar te ri al, venous, or capillary whole blood. Contents Each i-STAT cartridge contains one reference electrode (when potentiometric sensors are included in
CLIA Waived Tests and CPT Codes - Home :: Washington …
www.doh.wa.govAbbott i-STAT 6+ Cartridge (WB) i-STAT Corporation 84520QW Abbott i-STAT CHEM8+ Cartridge (WB) i-STAT Corporation 84520QW Arkray SPOTCHEM EZ Chem Analyzer (WB) Arkray, Inc. 84520QW Calcium Abaxis Piccolo Blood Chemistry Analyzer WB (Chem 13 Panel, CMP, BMP, Renal) Abaxis, Inc. 82310QW
PROCEDURE MANUAL FOR THE i-STAT SYSTEM
clinlab.uams.eduThe i-STAT System incorporates comprehensive components needed to perform blood analysis at the point of care. The system consists of the following primary components: i-STAT 1 Analyzer When a sample-filled i-STAT cartridge is inserted into the i …
Creatinine iSTAT methodology sheet
labmed.ucsf.eduUCSF Clinical Labs Page 2 of 6 Proc/iSTAT/Creat. Metrological Traceability The i-STAT System test for creatinine measures creatinine amount-of-substance
System: at the bedside The i-STAT System: A Comprehensive ...
poct.co.ukCARTRIDGES EXPECTED VALUES Reportable Range Reference Range Arterial Reference Range Venous Sodium (Na) Potassium (K) Chloride (Cl) TCO2 Anion Gapa Ionized Calcium (iCa) Glucose (Glu) Urea Nitrogen (BUN) Creatinine (Crea) Lactate
Title: i-STAT Operations and Testing Procedure
www.massgeneral.orgPOCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114 Title: i-STAT Operations and Testing Procedure
iSTAT1: Appendix F - Troubleshooting Guide
policyandorders.cw.bc.caProcedure: i-STAT Ceramic Conditioning Cartridge (CCC) for Analyzer Pin Conditioning REFERENCES. PHSA Laboratories CW Site - Point of Care Title: CWPC_BGE_0160 iSTAT1 Appendix F - Troubleshooting Guide Medical Approval: Dr Benjamin Jung Medical Approval Date: 22 …
i-STAT - Point Of Care Testing Ltd
www.poct.co.uki-STAT 1 Downloader Electronic Simulator Martel Printer See System Manual for instructions. For in vitro diagnostic use. 2 Intended Use: The i-STAT 1 Analyzer is intended for use with i-STAT cartridges
i-STAT ANALYSER SOFTWARE UPDATE - CLEW A33 / JAMS142
poct.co.ukDear i-STAT Customer CLEW A32 software expires 14-Dec-2016 at 8.00 a.m. and the new CLEW A33 / JAMS142 is valid until 21-Jun-17 at 8.00 a.m.. Please follow this 12 ...