Example: air traffic controller

06 99 RAY-VECTOR - Rosemex

RAY- vector WALL - FIN ENCLOSURESHYDRONIC HEATINGR osemex ProductsHEATING0699 INDEXSUPPORTS2 PAGESG eneral specifications .. 3 Bare element .. 4 Model RVS .. 6 Model RVF .. 8 Model RVT.. 10 Model RVE .. 12 Model RVX .. 14 Model IRVS .. 16 Model RVSVS .. 18 Model RVP .. 20 Model RVCES .. 22 Model RVCED .. 24 Optional accessories .. 25 System designing .. 26 Correction factors .. 27 ELEMENT SUPPORTFOR 1, 2 OR 3 ROWSFOR BOTTOM GRILLECABINETS ONLYELEMENT SUPPORTFOR 2nd OR 3rd ROWBARE ELEMENT SUPPORTTOP SUPPORTWELDED TO CABINETRC-8RE-3RE-1A UNIQUE DESIGNA llows installer a fast and easy align-ment, using only one levelled line atthe top of hanging strip is installed, thecabinet supports can be hooked to thehanging strip and fastened to wall will ensure perfect alignment ofthe top and bottom of the vector ENCLOSURESE nclosures are manufactu

A UNIQUE DESIGN Allows installer a fast and easy align-ment, using only one levelled line at the top of enclosure. Once hanging strip is installed, the

Tags:

  Vector, 06 99 ray vector

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 06 99 RAY-VECTOR - Rosemex

1 RAY- vector WALL - FIN ENCLOSURESHYDRONIC HEATINGR osemex ProductsHEATING0699 INDEXSUPPORTS2 PAGESG eneral specifications .. 3 Bare element .. 4 Model RVS .. 6 Model RVF .. 8 Model RVT.. 10 Model RVE .. 12 Model RVX .. 14 Model IRVS .. 16 Model RVSVS .. 18 Model RVP .. 20 Model RVCES .. 22 Model RVCED .. 24 Optional accessories .. 25 System designing .. 26 Correction factors .. 27 ELEMENT SUPPORTFOR 1, 2 OR 3 ROWSFOR BOTTOM GRILLECABINETS ONLYELEMENT SUPPORTFOR 2nd OR 3rd ROWBARE ELEMENT SUPPORTTOP SUPPORTWELDED TO CABINETRC-8RE-3RE-1A UNIQUE DESIGNA llows installer a fast and easy align-ment, using only one levelled line atthe top of hanging strip is installed, thecabinet supports can be hooked to thehanging strip and fastened to wall will ensure perfect alignment ofthe top and bottom of the vector ENCLOSURESE nclosures are manufactured in awide variety of models designed underthe Rosemex tradition of aesthetics,durability.

2 Strength and ease of models consist of element andcabinet supports hung from a continu-ous hanging strip. Enclosure lengthsare assembled together using con-cealed joiner strips to give a single unitlook in every room. The uniqueROSEMEX cabinet support designenables the installer to simply clip thebottom of the enclosure to the are made of quality coldrolled steel, 18, 16 or 14 gauge,formed and reinforced with top sup-ports, degreased, phosphatized andcoated inside and out with a corrosionresistant tan primer. Panels are manu-factured in lengths of 2 0 to 8 0 by 6 increments.

3 A wide variety of acces-sories are also available to suit are either non-ferrous(seamless coppertube with aluminumfins) or ferrous (firm steel tube withsteel fin). For both types of elements,the tubes are expanded within the finsto obtain a permanent thermal bondbetween the two. These are manufac-tured in lengths of 1 0 to 10 0 by 6 increments. Both elements can beused on either steam or hot water ELEMENTS,TYPES 34C & 44 CThese elements are used for their highheat transfer properties and optimumoutput. They are manufactured witheither 3 x 4 or 4 x 4 fins formed withan integral collar for uniform tube ends are manufactured toreceive standard sweat elements are designed foruse at 250 or 300 F max-imum working ELEMENTS,TYPE 44 SThese elements are used for theirsturdiness and are manufactured with4 x 4 steel fins.

4 The fins are formedwith an integral collar for uniform spac-ing. All tube ends are factory threaded,ready to receive standard 1 1/4 Rosemex steel elements aredesigned for use at 250 or 300 maximum working PIECEEnd pieces are used to close offenclosure ends when cabinets do notterminate on an adjacent wall. Theend piece is manufactured with round-ed corners and protrudes 1 beyondenclosure to give a neat TRIMJ oiners are manufactured to overlapenclosures and cover the gap betweencabinet end and adjacent wall orcolumns. These are usually supplied in4 , 5 , 6 or 8 JOINER (butt joint)Otherwise known as butt joint connec-tor , this piece fits between two enclo-sure lengths to give a clean hairlinejoint appearance to the CORNERI nside corners are manufactured tooverlap enclosures and are usedwhen piping runs on two or moreinside walls to meet heating require-ments.

5 These are usually supplied at90 angles, however may be modifiedto meet project CORNERO utside corners are manufactured tooverlap enclosures and are usedwhen piping runs on two or more out-side walls to meet heating require-ments. These are usually supplied at90 angles, however may be modifiedto meet project DOORSA ccess doors are manufactured to per-mit access to valves or other controlslocated inside enclosure. Two typesare available, factory installed 5 x 7 or field mounted 5 x 7 with are supplied as standard with ascrew lock, however a camlock type isalso field mounted access doors, thecontractor is required to perforate COVERSPipe covers are used to hide pipesthat run around a column.

6 These aresupplied in 5 , 11 or 17 heights andare 3 3/4 are knob operated hingedtype and are available for use on mostRay- vector models. The screw typemechanism is corrosion proof andsets the damper in any SPECIFICATIONS3 HangingStrip RE-1 ElementSupportAdjustmentSlotsCabinet SupportAnchoringRC-6 CABINET & ELEMENTSUPPORTFOR 1, 2 OR 3 ROWS12"12"4"3" 2 3/4"3 1/2"BARE ELEMENTDIMENSIONS44"4"3"4"2"2"Ordering lengthAvailable in lengths of 1 0" to 10 0" in 6" "4"Ordering lengthAvailable in lengths of 1 0" to 10 0" in 6" 1/2"2 1/2"TYPE RAF (series 34c, 44c)Aluminum Fins / Copper TubeTYPE RSF (series 44S3)

7 ARRANGEMENTSS teel Fins / Steel TubeCopper aluminum heating elements are manufactured ofseamless copper tube and aluminum fins permanentlybonded by mechanical in 3/4 , 1 and 1 1/4 copper tube sizes, allowyou to select the output and capacity to suit elements are constructed of 1 1/4 steelpipes and cold rolled steel fins, permanently bonded bymechanical process. They are hydrostatically tested andcoated with corrosion protecting extremities are threaded or may be chamfered forwelding if :Ball bearing supports supplied for this type of "3 3/4"2 3/4"3 1/2"6"6"4"3" 2 3/4"3 1/2"A-B-C-Type RSFSTEEL FINS / STEEL TUBENOTE: Water ratings have been determined by applying the IBR factors shown to the steam ratings and apply only when the water velocityis three feet per second.

8 For other flow rates use correction factors from table no. 1, page " x 4"52 Fin / " " x 4"52 Fin / " " x 4"52 Fin / " " x 4"48 Fin / 1/4" " x 4"48 Fin / 1/4" " x 4"48 Fin / 1/4" " x 4"52 Fin / " (INCHES) *44C1 34C1 44C2 34C2 44C3 34C3 44S3 PSIGFIN/TUBEBTU/HR/LIN. FT. 65 F ENT. AIRAVERAGE WATER TEMP. FALUMINUM FINS / COPPER TUBEA1B2C2A1B2C2A1B2C2A1B2C2A1B2C2A1B2C2 A1B2C2 BARE ELEMENT CAPACITIES5-1508129611761040920799678603 6249921491949172415241324112510001230532 626238121061862161813741221-127810989968 8177967757551162117182116511460129111229 528471225872224201817851578137111641034- 1516130411821046925803682606625132162196 0173415331332113110051230712641239521181 873162713811228-128511051002887784681578 5136212918311660146912991128958852122603 2238203017951587137911701040-15251311118 9105193080868660962528217319711744154213 4011371011123089265624092131188416371390 1235-12931112100889278868558151762142184 2167014771306113596485712261822512042180 61596138711781047-1267108998887477267157 0507621291831166014691299112895885212258 0221920121780 1573 136711601032*END PIECEOPTION 1 OPTION 2 OPTION 3 ACCESS PANELA-B-C-D-E-G-H-J-K-OUTSIDE CORNERWALL TRIMINSIDE CORNER12"3"18"3"24"3"18"3"6"24"3"6"24"3" 12"18"3"6"24"3"6"6"24"3"6"6"+ 1/2"Type RVS - GBottom Grille OptionalH3 7/8"Due to the air restriction, reduce capacities by 7 %.

9 RC - 8 Support 1 5/8"6 7/8"3 1/2"3 5/8"3" 6"12"6"12"4"12"18"24"2 3/4"2 3/4"5 1/4"Hanging StripAnchoringTopSupportCabinetSupportRC -6 ElementSupportRE-1 FloorHMODELDIMENSIONS6 RVSType (INCHES)ARRANGE-MENTS44C1 34C1 44C2 34C2 44C3 34C3 44S3 PSIGFIN/TUBEBTU/HR/LIN. FT. 65 F ENT. AIRAVERAGE WATER TEMP. FALUMINUM FINS / COPPER TUBEAHBJCDKEGAHBJCDKEGAHBJCDKEGAHBJCDKEG AHBJCDKEGAHBJCDKEGAHBJCDKEG1696145813231 1701034898762678188116181467129711479968 4675219701694153713591201104488778862435 2094189916801485129010969746256022021997 1766156113571152102312294525322297203217 9615611325117814371235112099187676164657 5159413701243109997284471763816691436130 1115210188847516676206417751609142412591 0939288256216918651692149613231149976867 1224962145194717211522132311239981705146 6132911761040904767682189216271476130511 5310028517571982170415451368120910508927 9262450210619101690149412981102979625762 2142009177715711364115910301229622547231 0204318061570133311851445124311279978817 6665057816031378125011069788507216411679 1443130911581023889755672620761785161814 3112661100933830621821876170215051330115 6982872122510215819581731153113301129100 4171514751338118310469097726861903163614 8413121160100885676119931714155513751216 1057897797624642119192217001503130611089 8562591222820201788158013731165103612297 9256223232055181715781340119214541250113 3100288777065458116121386125711129838547 2564416881451131711651029894759675620881 7951628144012731106939835621951887171115 1413391163987882122525217119691742153913 3811361010137011781068945836725616547151 3130111801044922802681605156713461221108 0955830705626621131816164814581289111995 0845621891882170715101335115998487612236 6203518451632144312541064946 MODELCAPACITIES7 RVS4" x 4"52 Fin / " " x 4"52 Fin / " " x 4"52 Fin / "


Related search queries