Example: bachelor of science

MOTORIZED CABINET HEATERS 200 TO 1010 CFM …

Rosemex Products HEATING797 FORCE-FLOW MOTORIZED CABINET HEATERS200 TO 1010 CFMCABINETThe cabinets are constructed of heavy16 gauge furniture steel with remov-able fronts to provide easy access tomotor, blower and heating cabinets are rust proofed andthen finished with a prime coat. Theycan be painted on the job to blendwith any color scheme or can be fur-nished with a factory enamel heating coils are of 5/8 copper tubes expanded intoaluminum fins to form a permanentmechanical bond. Two rows for hotwater or steam. Female pipe coil con-nections. Steam distributing coilshave cast iron headers. Supply andreturn connections on left side of unitson all models and blowers consist of two doubleinlet type centrifugal aluminum fansmounted directly on a double endedmotor DOORP rovides easier access to controls onleft side with camlock PANELS upplied on ceiling arrangements toremove fan deck & split capacitor type.

Rosemex Products HEATING 7 97 FORCE-FLOW ™ MOTORIZED CABINET HEATERS 200 TO 1010 CFM

Tags:

  Motorized, Cabinets, Heaters, Motorized cabinet heaters 200 to

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MOTORIZED CABINET HEATERS 200 TO 1010 CFM …

1 Rosemex Products HEATING797 FORCE-FLOW MOTORIZED CABINET HEATERS200 TO 1010 CFMCABINETThe cabinets are constructed of heavy16 gauge furniture steel with remov-able fronts to provide easy access tomotor, blower and heating cabinets are rust proofed andthen finished with a prime coat. Theycan be painted on the job to blendwith any color scheme or can be fur-nished with a factory enamel heating coils are of 5/8 copper tubes expanded intoaluminum fins to form a permanentmechanical bond. Two rows for hotwater or steam. Female pipe coil con-nections. Steam distributing coilshave cast iron headers. Supply andreturn connections on left side of unitson all models and blowers consist of two doubleinlet type centrifugal aluminum fansmounted directly on a double endedmotor DOORP rovides easier access to controls onleft side with camlock PANELS upplied on ceiling arrangements toremove fan deck & split capacitor type.

2 Steelshell, die cast aluminium shields, gal-vanized steel cradle. Resilient aligning sleeve bearings, horizon-tal mount, class B insulation, ther-mally protected. Windings are tropi-cal impregnated for high motors have been thoroughlytested to provide whisper quiet performance with speed variationsfrom high to SWITCHS olid state three speed control with in these CABINET HEATERS areremovable in seconds, without simply opening the unit s frontpanel, the filter easily slides are provided as clean air entering the cabinetheater before it is discharged into con-ditioned is provided to allow all pipingconnections to be made inside CABINET HEATER2 OPTIONAL EQUIPMENTNOISE LEVELPAGE3 HOT WATERPAGE4 STEAMPAGE5 WIRING DIAGRAMCOIL DIMENSIONSPAGE6 ROUGHING-IN DIMENSIONSPAGE7 ARRANGEMENTSPAGE8 High capacity, modern styling, wide range of appli-cation, the Rosemex CABINET heater can answerthe most exacting requirements of heating, ventila-tion and units are offered in five basic sizes.

3 Each sizeis available in twenty-six different arrangementsproviding hundreds of varieties of floor, wall or ceil-ing mounted UNIT SPECIFICATIONSOPTIONAL EQUIPMENT3 Can be provided in lieu of standard louver on out-let or inlet. Heavy duty bar grille of clear anodizedaluminum. Can be painted to match decorator col-ors if so requiredPermanent split capacitor 1650 RPM motor forhigher external static pressure or better throw ofair (especially on ceiling arrangements).Manual reset toggle switch starter with control by air temperature. Return air statmonitors incoming air to unit, starting blower, if thereturn air temperature drops below set is turned off when room temperature is satis-factory. Thermostat in CABINET for ceiling andinverted arrangements not controlled by the water temperature: Fancontrol delays the blower operation until returnwater temperature has reached a pre-determinedset of durable aluminum which has an averagearrestance of 61%.

4 Light and easy to flexible fiber glass duct liner on back andsides off external box, for recess easy access to the piping, valve, filter andfull access to fan for wall & floor ALUMINIUM BAR GRILLE2 HIGHER MOTOR3 MOTOR STARTER4 THERMOSTAT5 SURFACE AQUASTAT 6 PERMANENT FILTER7 INSULATION8 HINGED PANELRELATIVE NOISE LEVEL CLASSESCLASSESAREA1 Movie Theatres Offices Reception rooms Libraries Museums Court rooms Hospitals, Laboratories Recreation halls Waiting rooms Restaurants Night clubs Bowling alleys Gymnasiums General open offices Drafting rooms Barber shops, Washrooms & toilets Cafeterias Department stores Supermarkets Swimming pools Garages Laundries Hall and corridors Mills Heavy machinery maintenance Foundries, WATERFTABLE 1200 F EWT & 20 F DROPPERMANENT SPLITCAPACITOR MOTOR115/1 F EWT & 30 F F EWT & 40 F WATER CONVERSION FACTORS*SPECIAL TURBO - HIGH UNITSTABLE 2 AIRTEMPERATUREENTERING WATER TEMPERATURE F*To determine MBH capacity at any entering water temperature and entering air temperature, multiply rated capacities at 200 F EWT.

5 And 60 F EAT. obtained fromTABLE 1 by the appropriate conversion factor from TABLE 2. NOTE THAT THE USGPM REMAINS F ENTERING AIR TEMPERATURE1 x 1/151 x 1/151 x 1/42 x 1/152 x 1/41 x 1/4 SPECIAL TURBO - HIGH UNITSMODELSTEAM5 FSTABLE PSIG STEAMPERMANENT SPLITCAPACITOR MOTOR115/1/60 CFMSOUNDCLASSSTEAM CONVERSIONFACTORSTABLE PRESSURELB PER SQUARE IN. : Steam heating units are not available on inverted models. (Bottom discharged arrangements) F EATFS-300-AFS-300-BFS-300-CFS-400-AFS-40 0-BFS-400-CFS-600-AFS-600-BFS-600-CFS-80 0-AFS-800-BFS-800-CFS-1200-AFS-1200-BFS- 1200-CFS-300-TFS-400-TFS-600-TMODELAIR VOLUME FACTORS(CFM x FACTOR)BTUH CORRECTION FACTORS(MBH x FACTOR)INCHES OF WATERINCHES OF WATERF & FS-300F & FS-400F & FS-600F & FS-800F & FS-1200F-300-TF-400-TF-600-TAIR VOLUME & BTUH VS. EXTERNAL STATIC PRESSURETABLE 6 CFM CORRECTIONFACTORSTABLE 5 EAT F40 50 60 70 80 x 1/151 x 1/151 x 1/42 x 1/152 x 1/41 x 1/46 COIL DIMENSIONSCOIL DIMENSIONS1 1/4"17 / 32"7 13 / 16"2 3 / 4"4 3 / 4"17 / 32"LENGTH 7/8" RETURN4 1/2"2"HOT WATER COIL6 3/4"SUPPLYLENGTHSTEAM COIL1" FePT SUPPLYRETURN6 3/4"1 1/8"17 / 32"7 13/16" 2 7/8" 4 3/4"17/32"TYPESCONNECTIONSWATER3/4" " 3/4"27"35 3/4"48"64"TYPICAL WIRING DIAGRAMROUGHING-IN DIMENSIONS7 Pending CSA & NRTL APPROVAL # LR 101626-0000-000001 RETURN7 7/8"1"11 1/2"11 3/4"SUPPLY16"SUPPLY1 7/8"19 3/8"ABC7 7/8"G29"7 3/4"DIVISIONACCESSDOORRETURN7 7/8"1"11 1/2"11 3/4"SUPPLY16"RETURN1 7/8"19 3/8"7 7/8"INVERTEDSTANDARDINVERTEDSTANDARDBC1" SUPPLYDABRETURN1 7/8"19 3/8"7 7/8"ARETURN7 7/8"1"11 1/2"11 3/4"SUPPLYINVERTEDSTANDARDEEA1 1/2"TRIM MOULDINGMOUNTINGHOLE 3/8"1 1/2"1 1/2"ACCESSDOOR 16"SUPPLYRETURNFULLY-RECESSED : Wall & CeilingSEMI-RECESSED with Trim-moulding.

6 Wall & CeilingEXPOSED: Wall, Ceiling & FloorMODEL ABCDEGWEIGHT - LBSF & FS-30026"9 7/16"5 1/8"25 3/4"37 3/4"40 3/4"100F & FS-40026"9 7/16"5 1/8"29 3/4"42"45"110F & FS-60026"9 7/16"5 1/8"37 3/4"50 3/4"53 3/4"125F & FS-80026"9 7/16"5 1/8"49 3/4"63 1/8"66 1/8"190F & FS-120026"9 7/16"5 1/8"65 3/4"79"82"210 MECAR METAL , Marie-Victorin blvdSaint-Bruno (Quebec)J3V 6B9 ARRANGEMENTSFULLY EXPOSEDC/W HINGED PANEL*FULLY RECESSEDC/W HINGED PANEL**IMPORTANT: NOT AVAILABLE FOR RECESSEDFULLY EXPOSEDSEMI-RECESSEDWITH WALL TRIMWALL MOUNTEDFLOOR MOUNTEDCEILING MOUNTEDRW-4 IRW-4 PRINTED IN CANADAFULLY EXPOSEDNote: Steam units are not available on bottom discharged arrangements (IRW)Tel.: (450) 653-1002 Fax: (450) 653-3464


Related search queries