Example: quiz answers

10 9-1~9-8 8P

SNAP-IN. MOUNTING Intertek INTRODUCTIONS SPECIFICATIONS. 1. Rated voltage: 115 VAC/250 VAC. 1. Designed to meet globally accepted IEC publication 320 Class 1, that 2. Maximum leakage current each line-to-ground allows users to comply with industry standard in power entry requirement. 2uA AT 115 VAC/60Hz 2. Connector for cold condition, with pin temperature 70oC max. 5uA AT 250 VAC/50Hz 3. Nickel-plated brass pins and soldering terminals. 3. Dielectric strength (one minute). 4. Snap-in mount (panel thickness: inch to inch). line-to-ground: 2250 VDC. 5. Power module in plastic or metal case that incorporates an IEC line-to-line: 1450 VDC. connector, IEC 5x20mm fuse holder, power switch and voltage selector 4.

MECHANICAL CONSTRUCTION 06A5 06A1(Without voltage selector switch) 06A2 06A2D 1. 0 5 9 M A X. 2 6.. 1. 3 2 M A X. 6. 0 M A X. 1. 4 1 7 M A X 0. 2 8 3 5 X. 7. 0 1. 1 5 2 9. 2 L N 2.65 67.3 2 6. 9

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 10 9-1~9-8 8P

1 SNAP-IN. MOUNTING Intertek INTRODUCTIONS SPECIFICATIONS. 1. Rated voltage: 115 VAC/250 VAC. 1. Designed to meet globally accepted IEC publication 320 Class 1, that 2. Maximum leakage current each line-to-ground allows users to comply with industry standard in power entry requirement. 2uA AT 115 VAC/60Hz 2. Connector for cold condition, with pin temperature 70oC max. 5uA AT 250 VAC/50Hz 3. Nickel-plated brass pins and soldering terminals. 3. Dielectric strength (one minute). 4. Snap-in mount (panel thickness: inch to inch). line-to-ground: 2250 VDC. 5. Power module in plastic or metal case that incorporates an IEC line-to-line: 1450 VDC. connector, IEC 5x20mm fuse holder, power switch and voltage selector 4.

2 Flammability class: UL 94V-0. switch, all-in-one easy-to-install unit. Part numbers 06A1, 06A2, 06A2D and 06A5 are power modules in plastic case; part numbers 06AN2, 06AN2D, 06AN3, 06AN3D and 06AN5 are power modules in metal case. ELECTRICAL SCHEMATIC. 6. Fuse holder designed for one fuse. Safety interlock prevents fuse removal F F L SW. with line plug inserted. L. L L. L L. L L 110V 110V. 110V. 7. Adapts to 110V or 220V input voltage with voltage selector switch. I. N. O. A. I. N. O. A. D. 220V. E. 8. Compact design and high volume production provide maximum flexibility N. E D. N. N. G. N. G. 110V. and significant savings in space and cost over assembly of individual G G.

3 220V 110V. 110V. components. FIG. A FIG. B. CUSTOMER. TRANSFORMER. PRIMARIES. 9. All part numbers are UL recognized, CSA certified and SEMKO approved. 06AN3 ONLY 06AN3D ONLY. F SW F SW. L L L L. POWER ENTRY MODULES. L L L L. I O I O. N A N A. E D E D. N N N N. G G G G. FIG. C FIG. D. TYPE & RATED CURRENT. DELTA PART NUMBER 06A1 06A2 06A2D 06A5 REMARKS: * 1. SINGLE-POLE POWER SWITCH. UL/CSA (115 VAC/250 VAC) UL/CSA APPROVED AT 6A, 125 VAC/250 VAC. 4A VDE APPROVED AT 6A/250 VAC. RATED CURRENT 6A 6A 6A ELECTRICAL LIFETIME: 50,000 CYCLES. SEMKO MAXIMUM IN-RUSH CURRENT: 70A. * 2. DOUBLE-POLE POWER SWITCH. MALE ELECTRICAL LIFETIME: 10,000 CYCLES.

4 CONNECTOR TYPE MAXIMUM IN-RUSH CURRENT: 50A. FEMALE. * 3. VOLTAGE SELECTOR SWITCH. UL/CSA APPROVED AT 6A/125 VAC & 250 VAC. FUSE HOLDER S S S S VDE APPROVED AT 6A/250 VAC. POWER SWITCH - SP *1 DP *2 - VOLTAGE SELECTOR - - - FRONT *3. ELECTRICAL SCHEMATIC FIG. A FIG. C FIG. D FIG. B. DELTA PART NUMBER 06AN2 06AN2D 06AN3 06AN3D 06AN5 REMARKS: * 1. SINGLE-POLE POWER SWITCH. UL/CSA APPROVED AT 6A, 125 VAC/250 VAC. UL/CSA (115 VAC/250 VAC) 6A VDE APPROVED AT 6A/250 VAC. RATED CURRENT 6A 6A ELECTRICAL LIFETIME: 50,000 CYCLES. SEMKO 4A MAXIMUM IN-RUSH CURRENT: 70A. * 2. DOUBLE-POLE POWER SWITCH. MALE ELECTRICAL LIFETIME: 10,000 CYCLES. MAXIMUM IN-RUSH CURRENT: 50A.

5 CONNECTOR TYPE * 3. VOLTAGE SELECTOR SWITCH (FRONT). FEMALE. UL/CSA APPROVED AT 6A, 125 VAC/250 VAC. VDE APPROVED AT 6A/250 VAC. FUSE HOLDER S S S S S * 4. VOLTAGE SELECTOR SWITCH (REAR). UL/CSA/VDE APPROVED AT 10A/125 VAC&. POWER SWITCH SP*1 DP *2 SP *1 DP *2 - 5A/250 VAC. VOLTAGE SELECTOR - - REAR*4 REAR*4 FRONT *3. ELECTRICAL SCHEMATIC FIG. C FIG. D FIG. C FIG. D FIG. B. 9-5. 06A5. 06A2. 06A2D. MECHANICAL CONSTRUCTION. 06A1(Without voltage selector switch). 9-6. L. I. L. I. O. O. L. N. N. N. UNIT: mm INCH. (MOUNTING FROM FRONT). SUGGESTED MOUNTING CUTOUT. POWER ENTRY MODULES. MECHANICAL CONSTRUCTION. O. I. 06AN2. 06AN2D. POWER ENTRY MODULES.

6 O. I. 06AN3. 06AN3D. SUGGESTED MOUNTING CUTOUT. (MOUNTING FROM FRONT) (2X). (2X). The "0" "1" marking of Single and double-pole power on/off switches are reversed in position. 06AN5. INCH. UNIT: mm 9-7.