Example: confidence

1CEV30 - Overcenter Valve - Eaton

Eaton Screw-In Cartridge Valves E-VLSC-MC001-E 1 CEV30 data sheet December 2011 1. aAn Eaton Brand Where measurements are critical request certified drawings. We reserve the right to change specifications without and SpecificationsFigures based on: Oil Temp=40 C Viscosity = 32 cSt (150 SUS)Rated flow at 7 bar (100 psi) Delta P 30 L/min (8 USgpm)Max relief setting 270 bar (4000 psi)Max load induced pressure 210 bar (3000 psi)Cartridge material Working parts hardened and ground steel. External surfaces zinc position UnrestrictedCavity C-10-3 STorque cartridge into cavity 45 Nm (33 lbs ft)Weight kg ( lbs)Seal kit 02-173019 (Buna N) 02-173020 (Viton )Filtration BS5540/4 Class 18/13 (25 micron nominal)Temperature range -30 to +90 C (-22 - +194 F)Leakage

2.a eaton Screw-In Cartridge Valves E-VLSC-MC001-E 1CEV30 Data Sheet December 2011 An Eaton Brand Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Tags:

  Sheet, Data, Eaton, 1cev30, 1cev30 data sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 1CEV30 - Overcenter Valve - Eaton

1 Eaton Screw-In Cartridge Valves E-VLSC-MC001-E 1 CEV30 data sheet December 2011 1. aAn Eaton Brand Where measurements are critical request certified drawings. We reserve the right to change specifications without and SpecificationsFigures based on: Oil Temp=40 C Viscosity = 32 cSt (150 SUS)Rated flow at 7 bar (100 psi) Delta P 30 L/min (8 USgpm)Max relief setting 270 bar (4000 psi)Max load induced pressure 210 bar (3000 psi)Cartridge material Working parts hardened and ground steel. External surfaces zinc position UnrestrictedCavity C-10-3 STorque cartridge into cavity 45 Nm (33 lbs ft)Weight kg ( lbs)Seal kit 02-173019 (Buna N) 02-173020 (Viton )Filtration BS5540/4 Class 18/13 (25 micron nominal)Temperature range -30 to +90 C (-22 - +194 F)Leakage milliliters/min (5 dpm)Nominal viscosity range 5 to 500 cSt1 CEV30 - Overcenter ValvePilot assisted relief Valve with check 60L/min (15 USgpm) 270bar (4000psi)

2 DescriptionOvercenter valves give static and dynamic control of loads by regulating the flow into and out of hydraulic actuators. When installed close to or within an actuator, the Overcenter Valve will stop runaway in the event of hose burst and if open centre directional control valves are used, will allow thermal expansion relief of the hydraulic Overcenter cartridge is ideal for mounting directly into a cavity machined in the body of the cylinder, motor or rotary actuator. The cartridge can also be mounted directly to the ports via a specifically machined body as part of a Hydraulic Integrated Overcenter valves are normally used when the load is unidirectional, for example an aerial platform or crane and dual Overcenter valves are used for controlling loads in both directional for motor applcations or for cylinders going check section allows free flow into the actuator then holds and locks the load against movement.

3 The pilot assisted relief Valve section will give controlled movement when pilot pressure is applied. The relief section is normally set to open at a pressure at least times the maximum load induced pressure but the pressure required to open the Valve and allow movement depends on the pilot ratio of the optimization of load control and energy usage, a choice of pilot ratios is pressure required to open the Valve and start actuator movement can be calculated as follows:Pilot Pressure = (Relief Setting) - (Load Pressure)Pilot RatioFeaturesCartridge is economical and fits simple cavity. Allows quick, easy field service - reduces down time. Interchangeable with pilot check Valve of a similar Ratio5:1 (Standard) Best suited for Applications where loads vary and can introduce :1 Best suited for applications whereloadsremain relatively DropPerformance DataSectional View3125:1 Pressure Drop7:1 Pressure DropA = " Valve " to "Cyl" (Free Flow)B = "Cyl" to " Valve " (Piloted Open)Flow - L/minPressure - - barFlow - US gpmFlow - L/minPressure - psiBAPressure - barFlow - US (3) Valve (2)Cyl (1) Eaton Screw-In Cartridge Valves E-VLSC-MC001-E 1 CEV30 data sheet December 2011 Eaton Brand Where measurements are critical request certified drawings.

4 We reserve the right to change specifications without Function1 CEV302 AdjustmentF - Screw adjustment N- Fixed - For fixed versions add setting in 10 bar increments to end of part number +/- 10% (inch)Model Code3 Pressure Range 20 - 70-210 bar (1000 - 3000 psi) Standard setting 140 bar30 - 100-270 bar (1450 - 4000 psi) Standard setting 240 bar (3500 psi)Standard setting made at L/min 5 Pilot Ratio5 - 5:1 7 - 7:11 CEV30 - Overcenter ValvePilot assisted relief Valve with check 30L/min (8 USgpm) 270bar (4000psi)1 CEV30F30S5 4 SealsS - Buna N (for use with most industrial hydraulic fluids)SV - Viton (for high temperatures and most fluid applications)Cartridge OnlyBasic Code1 CEV30 1 2 3 4 5 Note:For applications above 210 bar please consult our technical department or use a steel :Tightening torque47 - 54 Nm (30-33 Ft/lbs)Cyl (1) Valve (2)Pilot (3) ( ) A/FHex socket adjust ( ) ( ) " -14 ( ) ( )


Related search queries