Example: air traffic controller

3A4144F, Proximity Switch, Instructions, English - …

instructions Proximity SwitchSingle control PNP Proximity switch used to detect lubrication cycles. (For use as an NPN Proximity Switch, see related manuals.)Not approved for use in European explosive atmosphere locations. Part Nos.: 17L879 -M11 x 1 Proximity Switch fits CSP Divider Valve5075 psi (35 MPa, 350 bar) Maximum Working Pressure17L880 - 3/4-16 Proximity Switch fits MXP Divider Valve8000 psi ( MPa, bar) Maximum Working Pressure17L983 - 7/16-20 Proximity Switch fits MSP Divider Valve7500 psi ( MPa, bar) Maximum Working Pressure17L881 - 1-3/8-16 Proximity Switch fits MGO Divider Valve6000 psi ( MPa, bar) Maximum Working Pres-sure17M380 - 1/8 NPS Proximity Switch fits MD/MJ Divider Valve3000 psi ( MPa, bar) Maximum Working PressureRelated ManualsImportant Safety InstructionsRead all warnings and instructions in this manual and the instructions included with your operating system or pump. Save these Title3A4481 Proximity Switch Cable3A4144 FENI nstallation 23A4144 FInstallation1.

Installation 2 3A4144F Installation 1. Disconnect power. 2. Relieve pressure. See Pressure Relief Procedure in the pump instruction manual included with your

Tags:

  Installation, Instructions, English, Installation 1

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 3A4144F, Proximity Switch, Instructions, English - …

1 instructions Proximity SwitchSingle control PNP Proximity switch used to detect lubrication cycles. (For use as an NPN Proximity Switch, see related manuals.)Not approved for use in European explosive atmosphere locations. Part Nos.: 17L879 -M11 x 1 Proximity Switch fits CSP Divider Valve5075 psi (35 MPa, 350 bar) Maximum Working Pressure17L880 - 3/4-16 Proximity Switch fits MXP Divider Valve8000 psi ( MPa, bar) Maximum Working Pressure17L983 - 7/16-20 Proximity Switch fits MSP Divider Valve7500 psi ( MPa, bar) Maximum Working Pressure17L881 - 1-3/8-16 Proximity Switch fits MGO Divider Valve6000 psi ( MPa, bar) Maximum Working Pres-sure17M380 - 1/8 NPS Proximity Switch fits MD/MJ Divider Valve3000 psi ( MPa, bar) Maximum Working PressureRelated ManualsImportant Safety InstructionsRead all warnings and instructions in this manual and the instructions included with your operating system or pump. Save these Title3A4481 Proximity Switch Cable3A4144 FENI nstallation 23A4144 FInstallation1.

2 Disconnect pressure. See Pressure Relief Procedure in the pump instruction manual included with your operating Remove plug or Proximity switch from the divider block piston port you will be using to install the prox-imity Screw the Proximity switch into the port. Torque to tighten. See Torque Table for the correct Torque value for your Table5. If an adapter cable is used, attach the proper con-nector to the existing cable. Continue instructions with Step If using the M12 wireable cable (sold separately), connect the signal wire to lube system Attach the power wires to the power Screw the M12 connector into the Proximity If optional LED cables are used: verify the yellow status indicator LED illuminates when the switch is activated and there is power supplied to the and DimensionsSKIN INJECTION HAZARD High-pressure fluid from dispense valve, hose leaks, or rup-tured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation.

3 Get immediate surgical treatment. Do not point dispense valve at anyone or at any part of the body. Do not put your hand over the dispense nozzle. Do not stop or deflect leaks with your hand, body, glove, or rag. Follow Pressure Relief Procedure when you stop dis-pensing and before cleaning, checking, or servicing equipment. Part Divider ValveThreadSizeTorque Valueft-lbsN m17L879 CSPM11 x - - 1646 - - - - - 16 70 - 7595 - 10217M380MD/MJ1/8 NPS5 - - Electrical ratings must not be exceeded. Overload on a switch can cause switch to fail on the first cycle. Never exceed pressure limits. Unit can be operated up to maximum pressure. FIG. in. ( mm)Wiring Diagram,Dimensionsfrom switch endTechnical Data3A4144F3 Technical DataUSMetricElectrical DesignDC PNPO utputNormally openOperating - 32 DCShort-Circuit ProtectionPulsedMaximum Operating PressureModel 17L8795,075 psi35 MPa (350 bar)Model 17L8808,000 MPa ( bar)Model 17L9837,500 MPa ( bar)Model 17L8816,000 MPa, ( bar)Model 17M3803,000 MPa ( bar)Current Rating500 mAVoltage Drop< VCurrent Consumption<25 mAMaximum Switching Frequency100 HzProtectionIP65, IP68, IP69 Insulation Resistance>100 (500 V DC)Shock ResistanceDIN IEC 68-2-27: 50 g (11 ms)Vibration ResistanceDIN IEC 68-2-6: 20 g ( Hz)Switching Cycles 50 millionConnectionM12 EMCEN61000-4-2 ESD4 kV CD/8 kV ADEN61000-4-3 HF radiated10 V/mEN61000-4-4 Burst2 kVEN61000-4-6 HF conducted10 VSensing mm (f)Wetted Partsstainless steel, 316 , 304 stainless steelHousing MaterialsPBT (Pocan); PC (Makrolon).

4 FPM, stainless steel 316 oz kgModel kgModel kgAmbient Temperature Range-13 to 176 F-25 to 80 CMedium Temperature Range-13 to 176 F-25 to 80 CStorage Temperature-40 to 212 F-40 to 100 CAll written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without instructions . This manual contains English . MM 3A4144 Graco Headquarters: MinneapolisInternational Offices: Belgium, China, Japan, KoreaGRACO INC. AND SUBSIDIARIES BOX 1441 MINNEAPOLIS MN 55440-1441 USAC opyright 2016, Graco Inc. All Graco manufacturing locations are registered to ISO E, May 2018 Graco Information TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest : 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590