47775E D9412G-D7412G PEG - Bosch Security

ENProgram Entry GuideControl PanelsD9412G/D7412GD9412G/ d7412g | Program Entry Guide |EN | 2 Bosch Security Systems | 1/04 | 47775 ETrademarksCoBox is a registered trademark of Lantronix .Windows is either a registered trademark of MicrosoftCorporation in the United States and/or ConventionsType Styles Used in this ManualTo help identify important items in the text, thefollowing type styles are used:Bold textUsually indicates selections thatyou might use while programmingyour control panel. It can alsoindicate an important textUsed to refer the user to anotherpart of this manual or anothermanual entirely. It can also used tosymbolize names for records thatthe user TextIndicates what can appear on theRemote Programmer s display,command center/keypad orinternal printer.

D9412G/D7412G | Program Entry Guide | 1.0 Introduction EN | 6 Bosch Security Systems | 1/04 | 47775E 1.4 New Features The items shown Table 3 are new features added to the D9412G/D7412G Control Panels since version 6.10.

Tags:

  Control, D9412g d7412g, D9412g, D7412g, D9412g d7412g control

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 47775E D9412G-D7412G PEG - Bosch Security

1 ENProgram Entry GuideControl PanelsD9412G/D7412GD9412G/ d7412g | Program Entry Guide |EN | 2 Bosch Security Systems | 1/04 | 47775 ETrademarksCoBox is a registered trademark of Lantronix .Windows is either a registered trademark of MicrosoftCorporation in the United States and/or ConventionsType Styles Used in this ManualTo help identify important items in the text, thefollowing type styles are used:Bold textUsually indicates selections thatyou might use while programmingyour control panel. It can alsoindicate an important textUsed to refer the user to anotherpart of this manual or anothermanual entirely. It can also used tosymbolize names for records thatthe user TextIndicates what can appear on theRemote Programmer s display,command center/keypad orinternal printer.

2 [CAPITALIZEDTEXT]Used to indicate that a specific keyshould be thick border is used to indicate amain programming entry as seenin the Remote Programmer sDisplay. It is used as a sectionheading and screen boxes indicateprogrammer prompts that are onlyavailable when Custom or Viewevents are dashed border indicates a subentry under a main , Notes, Cautions and WarningsThroughout this document helpful tips and notes arepresented concerning the entire application and/orprogramming the unit. They are displayed as follows:Application Tip:These are helpful shortcuts or reminders inusing the Note:These are notes and clarifications ofdifferent aspects of the Notes:These cover notes and clarificationsspecific to programming the Tip:These are helpful shortcuts or reminders forprogramming the NotesThese notes should be heeded forsuccessful operation and !

3 These warn of the possibility of physicaldamage to the operator, program and/orequipment. Use this when there is anincreased risk of physical damage to theoperator (severe injury or death) orequipment (destruction of physicalcomponents).CautionThese caution the operator that physicaldamage to the program and/or control | Program Entry Guide | Table of ContentsEN | 3 Bosch Security Systems | 1/04 | 47775 ETable of to use this Program Entry Between the d9412g andD7412G .. the control Panel with theD5200 .. Parameters .. Party Disconnect .. Number Groups: Which Has theHighest Priority? .. a Primary and BackupDestination .. Routing .. a Duplicate Destination Prioritization within a Routing.

4 A Primary and BackupDestination .. a Duplicate Supervision .. Parameters .. Parameters .. and Downloading Reports .. Threshold Reports .. Callback Reports .. Account Numbers in 9000 Series control Panels, versions andHigher .. Characteristics .. Parameters .. Options .. Cmd Cntr (Command Center) Area Text .. Custom Interface .. Command Center Selections .. Authority Level Selections .. List .. Parameters .. Area Panel-Wide Relays .. Group Window .. Level by Area .. Name .. and Index .. 7 and COMMAND 9 .. and Group Indexes .. Holidays .. IV and D5200 Automation.

5 RAM Interface Modifications forCOMMAND an External Path Numbers andIP Addresses .. RAM/Enhanced Group Attempts .. 126D9412G/ d7412g | Program Entry Guide | Table of ContentsEN | 4 Bosch Security Systems | 1/04 | .. Point Parameters .. Prompts Directory ..136 FiguresFigure 1: Pager Display 2: Account Number Entry ..36 Figure 3: User Group 122 4: Example Opening Window Timeline (usingtwo Opening Windows on same day)..97 Figure 5: COMMAND 43 Flow 6: RAM IP Address 7: Com Port Selection 8: External Modem Connection ..120 Figure 9: Path # IP Add1 to Add4 ..123 Figure 10: Poll Rate 1: Literature Referenced .. 5 Table 2: Differences between the d9412g andD7412G.

6 5 Table 3: New Features .. 6 Table 4: Product Handlers .. 8 Table 5: Programming Error 9 Table 6: Modem IIIa2 Communication Format Data -User ID 7: Modem IIIa2 Communication Format Data Point Numbers ..13 Table 8: Zones ..13 Table 9: Diagnostic 10: Burglar Reports ..18 Table 11: User Reports ..19 Table 12: Test 13: Diagnostic 14: Relay Reports ..21 Table 15: Auto-Function Reports ..21 Table 16: RAM Reports ..22 Table 17: Point Reports ..22 Table 18: User Change Reports ..23 Table 19: Access Reports ..23 Table 20: Event Descriptions, Priorities, 21: Programming Four Digit AccountNumbers .. 35 Table 22: Programming Ten Digit AccountNumbers .. 35 Table 23: Verify 37 Table 24: CF### Custom Function 52 Table 25: Command Center ProgrammingChoices.

7 53 Table 26: Authority Level Selections .. 59 Table 27: L## Secure Door-Door ModeDefinitions .. 62 Table 28: BSFK User Code Report .. 74 Table 29: P### BFSK/Relay 93 Table 30: Point Text for Points 240 to 93 Table 31: Window Selections .. 95 Table 32: Programming for Two Same Day OpeningWindows (see Figure 4).. 98 Table 33: Programming to Link Two Days overMidnight .. 98 Table 34: W# Close Window Stop 99 Table 35: Opening/Closing Windows 101 Table 36: Opening/Closing 101 Table 37: Normal Store Hours* .. 101 Table 38: Delivery Schedule*.. 102 Table 39: Monthly Auditor s Schedule*.. 102 Table 40: Cross Point Ranges Within Groups .. 128D9412G/ d7412g | Program Entry Guide | IntroductionEN | 5 Bosch Security Systems | 1/04 | to use this Program Entry GuideThis guide addresses the programming of theD9412G/ d7412g control Panels only, and should notbe used in conjunction with other control this guide specifically refers to the D9412 GControl Panels, it can be used for programming theD7412G control Panels.

8 Differences between theD9412G and d7412g are shown Table ReferencedThroughout this guide, references are made to otherdocuments. See Table 1 for a part numbers list of thereferenced literature for ordering the following documents before installing andprogramming the 1: Literature ReferencedDocument NamePart Number1. D1255 Installation Instructions74-06819-0002. D1256/D1257 InstallationInstructions74-06925-0003. D1260 Installation Guide481014. D1260 Owner s Manual504105. D5200 Operations Manual74-06176-0006. D6500 Report Directory74-04651-0017. D6600 CommunicationsReceiver/Gateway ComputerInterface Manual399638. D720 Installation Instructions74-06918-0009. D9210B Operation andInstallation Guide3220610.

9 D9210B Program Entry Guide3220711. D9210B Program Record Sheet3220812. d9412g / d7412g Operationand Installation Guide4348813. d9412g / d7412g ProgramRecord Sheet4748814. RPS Operations Between the D9412 Gand D7412 GTable 2 describes the differences between the D9412 Gand the d7412g control 2: Differences between the d9412g andD7412 GFeaturesD9412GD7412 GAccess ControlYesEight DoorsYesTwo DoorsExpanded usersArm/disarm PasscodesCards/tokens24999699396 Passcode-protectedcustom functions164 Number of printers31 Number of points24675 Number of relays12864D9412G/ d7412g | Program Entry Guide | IntroductionEN | 6 Bosch Security Systems | 1/04 | FeaturesThe items shown Table 3 are new features added to the d9412g / d7412g control Panels since version 3.

10 New FeaturesFeatureDescriptionGround Fault Detect(Version )For the d9412g / d7412g to detect ground fault conditions, the earth ground terminal on thecontrol panel was electrically isolated from all other terminals. A ground fault detect enable switch(S4) was added to the control panel and is located under Terminal 10, earth ground. For moreinformation on the operation of this function, see the d9412g / d7412g Operation and InstallationGuide (P/N: 43488).Added Feature whenUsing Ground FaultDetect (Version )When ground fault detect is enabled (S4 closed), Points 1 to 8 can be used for non-powered fire-initiating devices; such as, heat detectors, 4-wire smoke detectors, or pull stations.