LCS-6A MESTEK COMPANYCOMMERCIAL HYDRONIC PRODUCTS Light Commercial Slope-TopEnclosures for Hydronic HeatingLCS-10 INTRODUCING THE LCS-10 FEATURESGENERAL LAYOUTS terling Light Commercial Slope-Top EnclosuresThe Sterling LCS-10 offers an outstanding value in a lightcommercial hydronic heating enclosure. Capable of utilizingtwo tiers of element, the LCS-10 offers high output in alow profile slope-top enclosure. The 3 1/4 inch depth andslope top make this attractive enclosure a real elements are available in both copper/aluminumand steel in a wide variety of sizes and ease of installation, the LCS-10 features a self locatingbracket with pre-punched mounting holes.

LCS-6 A MESTEK COMPANY COMMERCIAL HYDRONIC PRODUCTS ® Light Commercial Slope-Top Enclosures for Hydronic Heating LCS-10

Tags:

  Company, Semtek, A mestek company

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of A MESTEK COMPANY - mesteksa.com

1 LCS-6A MESTEK COMPANYCOMMERCIAL HYDRONIC PRODUCTS Light Commercial Slope-TopEnclosures for Hydronic HeatingLCS-10 INTRODUCING THE LCS-10 FEATURESGENERAL LAYOUTS terling Light Commercial Slope-Top EnclosuresThe Sterling LCS-10 offers an outstanding value in a lightcommercial hydronic heating enclosure. Capable of utilizingtwo tiers of element, the LCS-10 offers high output in alow profile slope-top enclosure. The 3 1/4 inch depth andslope top make this attractive enclosure a real elements are available in both copper/aluminumand steel in a wide variety of sizes and ease of installation, the LCS-10 features a self locatingbracket with pre-punched mounting holes.

2 The stampedpencil-proof louvers prevent trash accumulation on theelement while meeting the specifications of demandingengineers and architects. And, because the LCS-10 doesnot require a full backplate, it can be mounted off of thefinished Sterling LCS-10 enclosures feature a durable baked pow-der finish and are available in Sterling s full selection ofcolors. Constructed of 18-gauge cold rolled steel (16-gauge optional), this durable enclosure is ideal for dormi-tories, military housing, nursing homes, offices and recep-tion areas. Two tier capacity Heavy 18-gauge enclosure (16-gauge optional) Narrow 3 1/4 inch depth Low 10 1/4 inch height Stamped pencil-proof louvers Broad choice of elements Baked powder finish Self-locating bracketsAll Sterling commercial hydronic products are made fromrecycled materials.

3 Material recycled contents can beobtained from your local Sterling representative or byviewing the Sterling is aparticipating member of SIZE 1"1"11 4"CATALOGDESIGNATIONR11R12R13 FIN SIZEHEIGHT X WIDTH3 3/4 X 2 3/45 X 2 3/45 X 2 3/4 INCHES14 1 414 1 414 1 4 STEAM215 WATER (AVG.)200 190 180 170 160 150 FACTORSTEEL ELEMENTTUBE SIZE3/4"1"CATALOGDESIGNATIONR02R03 FIN SIZE HEIGHT X WIDTH2 1/2 X 2 3/42 1/2 X 2 3/4 INCHES14 1 414 1 4 STEAM215 WATER (AVG.)200 190 180 170 160 150 FACTORCOPPER ALUMINUM ELEMENTTUBE SIZE3/4"3/4"1"1"1"1"11 4"11 4"11 4"CATALOGDESIGNATIONR02R04R03R05R06R07R0 8R09R10 FIN SIZEHEIGHT X WIDTH2 1/2 X 2 3/43 3/4 X 2 3/42 1/2 X 2 3/43 3/4 X 2 3/45 X 2 3/45 X 2 3/43 3/4 X 2 3/45 X 2 3/45 X 2 3/4 INCHES14 1 414 1 414 1 414 1 414 1 414 1 414 1 414 1 414 1 4 STEAM215 WATER (AVG.)

4 200 190 180 170 160 150 FACTORCOPPER/ALUMINUM ELEMENTRATING BTU/H WITH (2) TIER ELEMENT 31 2" CENTEREDThe ratings of the charts above include factors shown in the chart below for the recommended mounting height. Two tier ratings are based on 31 2" between are in BTU per hour per lineal foot of active length. Active length is the catalog ordering length less 4". The water ratings applicable to water flow rates of three ormore feet per second, have been determined by applying factors shown to the Steam Ratings. Elements unpainted. If the unit is to be installed at a height different than therecommended mounting height, the rating must be adjusted as follows:RATING MULTIPLIED BY:FACTOR FROM TABLE B FOR THE ACTUAL MOUNTING HEIGHT FACTOR FROM TABLE B FOR THE RECOMMENDED MOUNTING HEIGHTMOUNTING HEIGHT IN 3 1/4" OFFSET18 or or BCAT 15/16( )6 1/6(154)6 9/16( )6 9/16( )7 1/8(181)6 11/16( )7 3/16( )6 11/16( )7 3/16( )A 7/16( )8 5/8( )8 15/16(227)9 1/8( )8 11/16( )9 1/4(235)8 11/16( )9 3/16( )8 11/16( )Dimensions are in inches.

5 Dimensions in parentheses are in millimetersRATINGS LCS-10uuuuuuuuu Bold, italicized units are rated tA MESTEK COMPANY260 North Elm Street, Westfield, MA 01085 Tel: (413) 564-5535 FAX: (413) and install where shown on all plans/drawings, Sterling LCS-10 Finned Tube Enclosure and Element as describedor approved equal of both quality and BTU capacity. Ratings are to be AHRI finned tube enclosure, as called out LCS-10, will be manufactured from 18-gauge (16-gauge optional) bonderized a baked powder prime finish. The air discharge louvers are to be die formed stamped into the steel enclosure.

6 The louver open-ings are to be Pencil Proof . All lateral bends are to be formed on bottoming dies to ensure continuity of all adjoining enclosures andaccessories. The enclosure lengths are to be provided in 6 inch increments from 2 feet through 8 feet long. The enclosure is to fullyengage in a continuous full length mounting strip mounted to the wall. A two (2) inch joiner strip is to be used where two pieces ofenclosure are adjoining each other in a accessories will be die formed 20-gauge cold rolled steel and finished with the baked prime finish described above. Theaccessories will overlap the installed enclosure and are to provide adjustment for make-up in the installed runs of brackets are to be of a one piece, die formed construction.

7 The material is to be 14-gauge with a baked primefinish. The bracket is to be self locating for vertical positioning at installation. The bottom horizontal leg is to snap into bottom bend ofthe enclosure and is to support the element when slide shoes are used. The top horizontal leg is to support the adjustable elementhanger. Adjustable rod hangers are to be supplied when specified. These will be used in conjunction with the various elements thatdo not incorporate a nylon slide. They will also be used when the installation requires pitch adjustment for steam mounting strip is to be supplied in eight (8) foot lengths.

8 It will be die formed heavy gauge, galvannealed elements are to be of the mechanically expanded type to ensure that proper fin to tube bonding is elements are to be provided with one end mechanically swaged (flared) for proper assembly. Steel/Steel elementare to be provided with both ends threaded to accept all domestic NPT fittings or cut square and chamfered for field the interest of product improvement, we reserve the right to make changes without FOR THE LCS-10 ACCESSORIES6" (152 mm) End CapWith Access Door14" (356 mm) Fill-In SectionOutside Corner2" (51 mm)Splice Plate3" (76 mm) End Cap135 Outside Corner6" (152 mm) End Cap3" (76mm) or 6" (152 mm)Wall SleeveInside Corner90 & 135 8" (203 mm) Valve CompartmentCOMMERCIAL HYDRONIC PRODUCTS