Advisory Bulletin - Bobrick Washroom

Advisory Bulletin TB-32 suggested mounting Systems for Ceiling-Hung Toilet Partitions FRONT VIEW Provisions must be in the construction of the building to support ceiling-hung toilet partitions. Structure 3/8'' 10mm Threaded Rod in ceiling, not furnished by Bobrick , must support at least 295 lb per laminated-plastic partition and 275 lb per solid-phenolic partition, and must be sufficiently Leveling 2-1/2''. rigid to withstand swinging motion of toilet partition Device Finished 64mm Ceiling doors and impact of doors against stiles. Some Heliarc suggested mounting systems are shown below. Shoe Weld Actual mounting system , including lateral bracing, 11-Gauge if required, must be designed by the architect or Steel Plate Stile structural engineer, and furnished by others. Note: If adequate ceiling support cannot be provided, the floor and ceiling-anchored or overhead-braced Approximate Weight: toilet compartments are recommended.

Advisory Bulletin continued . . . TB-32 Suggested Mounting Systems for Ceiling-Hung Toilet Partitions Provisions must be in the construction of the building

Tags:

  System, Suggested, Mounting, Suggested mounting systems

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Advisory Bulletin - Bobrick Washroom

1 Advisory Bulletin TB-32 suggested mounting Systems for Ceiling-Hung Toilet Partitions FRONT VIEW Provisions must be in the construction of the building to support ceiling-hung toilet partitions. Structure 3/8'' 10mm Threaded Rod in ceiling, not furnished by Bobrick , must support at least 295 lb per laminated-plastic partition and 275 lb per solid-phenolic partition, and must be sufficiently Leveling 2-1/2''. rigid to withstand swinging motion of toilet partition Device Finished 64mm Ceiling doors and impact of doors against stiles. Some Heliarc suggested mounting systems are shown below. Shoe Weld Actual mounting system , including lateral bracing, 11-Gauge if required, must be designed by the architect or Steel Plate Stile structural engineer, and furnished by others. Note: If adequate ceiling support cannot be provided, the floor and ceiling-anchored or overhead-braced Approximate Weight: toilet compartments are recommended.

2 Laminated Plastic Partition 295 lb The stiles of Bobrick ceiling-hung toilet partitions Solid Phenolic Partition 275 lb are constructed with an 11-gauge steel core welded to a leveling device. Each leveling device includes threaded rods (2), hex nuts (6), spacers (2), flat washers (4), lock washers (4), shoe retainers (2), and expansion anchors (2). 4" (102mm) stainless steel shoe, which is furnished, covers the leveling device after installation is completed. Side Views Alternate Alternate Position Position I-Beam for Furred for Furred (not furnished) Down Ceiling Down Ceiling Hex Nut Typ. Channel Channel Bevel Washer Typ. (not furnished) (not furnished). Spacer Typ. 2-1/2'' Ceiling Ceiling 2-1/2'' Shoe Retainer Typ. 2-1/2'' Ceiling 64mm 64mm 64mm Washer Typ. Threaded Rod Typ. Shoe Typ. I-Beam Support Channel Support Angle Support continued .. Revised 03/12/18 Printed in 2018 by Bobrick Washroom Equipment, Inc.

3 Recommended Methods for Attaching to Wall Wall Wall Expandable Plug Sheet Metal Screw Metal Backing Wire Tie Panel or Stile Panel or Stile Masonry Wall Sheet Metal Wall Stud (wood or metal). Sheet Metal Screw Steel or Wood Backing Panel or Stile Stud wall Setting Bed and Lath Stud 3/16'' x 3'' (5 x 76mm). Tile Wall Steel Plate - Drill and Tap Plastic Anchor for 1/4-20 Machine Screw (furnished). 1/4-20 Machine Screw Sheet Metal Screw Panel or Stile Panel or Stile Stud Plaster Tile Wall with Setting Bed Plaster on Stud Wall TB-32 Rev 03/12/18 Printed in 2018 by Bobrick Washroom Equipment, Inc.