Example: dental hygienist

ASCO 7000 SERIES Power Transfer Switches

Healthcare FacilitiesCommercial Buildings / Industrial BuildingsWeb Hosting, Internet Data CentersTelecom Central OfficesProcess Manufacturing / Wafer Fabrication Plants /Distributed Power / Load Management2 Critical Loads Demand ASCO7000 SERIESASCO As we become more depend-ent on the quality and reliabili-ty of electrical Power , inter-ruption or complete loss ofpower can create serious andeven crippling financial losses,or impose dangers to life andsafety. asco Power Technologies( asco ) provides the solutionsto handle the Transfer ofcritical loads to emergencysources reliably and with stateof the art products. UsingASCO products can mean the difference between a minorinconvenience and a majorcatastrophe. You ll find ASCOP ower Transfer Switcheswherever there is a criticalload to be flexibility in powerswitching is a must, asco offers a variety of product solutions to meet virtuallyevery application require-ment, including distributedgeneration s why the 7000 SERIESis available in open, delayed,closed and closed soft loadconfigurations.

systems. 7000 series Power Transfer Switches are available open or enclosed, ... 400 Amp Switch in a Type 1 Enclosure. 4. ASCO 7000 SERIES POWER SWITCHING SOLUTIONS Open Transition Transfer Switching ASCO Transfer Switches are available in a standard, 2-position,

Tags:

  Series, Switching, Types, Power, Asco, 7000, Enclosed, Asco 7000 series power, Asco 7000 series power switching

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ASCO 7000 SERIES Power Transfer Switches

1 Healthcare FacilitiesCommercial Buildings / Industrial BuildingsWeb Hosting, Internet Data CentersTelecom Central OfficesProcess Manufacturing / Wafer Fabrication Plants /Distributed Power / Load Management2 Critical Loads Demand ASCO7000 SERIESASCO As we become more depend-ent on the quality and reliabili-ty of electrical Power , inter-ruption or complete loss ofpower can create serious andeven crippling financial losses,or impose dangers to life andsafety. asco Power Technologies( asco ) provides the solutionsto handle the Transfer ofcritical loads to emergencysources reliably and with stateof the art products. UsingASCO products can mean the difference between a minorinconvenience and a majorcatastrophe. You ll find ASCOP ower Transfer Switcheswherever there is a criticalload to be flexibility in powerswitching is a must, asco offers a variety of product solutions to meet virtuallyevery application require-ment, including distributedgeneration s why the 7000 SERIESis available in open, delayed,closed and closed soft loadconfigurations.

2 Additionally,switched or overlappingneutral options provide forreliable operation of groundfault protection systems andreduction of voltage tran-sients from unbalanced Power Transfer Switchesare the first CE Marked, IEC60947-6-1 compliant TransferSwitches in the world. The Recognized Leader in Power Transfer Switch Technology Conventional two-position Transfer configuration, plus closed and delayed transition modes of operation. All configurations available with either automatic or non-automatic control. UL listed to 1008 Transfer Switch Equipment & CSA certified to CSA AutomaticTransfer Switches . Qualified and certified to IEC 60947-6-1, CE marked(optional). (Limited to certain accessories.) Rated up to 600 VAC, 30 through 4000 amperes.

3 Reliable and field proven solenoid operating mechanism. High withstand and close-on ratings including short timewithstand current rating for optimum flexibility in circuitbreaker coordination (600-4000 amperes). Solid, switched, or overlapping neutral conductor Power Transfer Switches are the standard of theindustry. High speed Transfer of loads between alter-nate sources of Power , regardless of ampacity size, isachieved by a reliable, field proven solenoid operatingmechanism. When combined with a programmablemicroprocessor controller with keypad and LCD display,they offer the most advanced method of transferring alltypes of loads, such as motors, electronic drives, UPSsand microprocessor based systems. 7000 SERIESP owerTransfer Switches are available open or enclosed , inampacity sizes from 30 through 4000 amperes with thelargest selection of optional accessories offered any-where.

4 All switching configurations are available with anintegrally mounted bypass-isolation switch and/or ratedfor use in service entrance applications. Front replaceable main and arcing contacts (800-4000 amperes). Programmable microprocessor controller with keypad andLCD display. Centrally located terminal block for customer control connections (260-4000 amperes). 16mm, industrial grade control Switches and indicating lights. Switch position LED indicators and source acceptability lights. Standard ground conductor connections. Four auxiliary contacts, two contacts closed when switch is in normal position and two contacts closed when switch is in emergency position. Local/remote communications capability for interfacing with asco PowerQuest or SiteWeb SERIES7000 SERIESP ower Transfer SwitchesProduct FeaturesOffers the Most Advanced Transfer Switches in the 1:Three Pole 7000 SERIESA utomatic Transfer Switchrated 1600 amperes (shown with optional front connected terminals and Power Manager).

5 asco Delayed Transition Transfer SwitchingFig. 3:Four pole, Delayed Transition Transfer Switch rated 2000 Delayed Transition Transfer Switches are designed toprovide Transfer of loads between Power sources with atimed load disconnect position for an adjustable period oftime. Applications include older style variable frequencydrives, rectifier banks, and load management applications. Available 150 through 4000 amperes. Utilizes reliable, field proven solenoid operating mechanisms. Mechanical interlocks to prevent direct connection of bothsources. Indicator light (16mm, industrial grade type LED) for load disconnect position. Adjustable time delay for load disconnect Transition Transfer SwitchingASCO Automatic Closed Transition Transfer Switches featuremain contacts that overlap, permitting the Transfer of electricalloads without Power interruption.

6 The switch transfers in amake-before-break mode if both sources are within acceptableparameters. Control logic continuously monitors source conditions and automatically determines whether the loadtransfer should be open (conventional non-overlap mode) orclosed transition. Available 150 through 4000 amperes. Closed Transition Transfer within 5 electrical degrees is achievedpassively, without control of engine generator set. Therefore, noadditional control wire runs are required between the ATS andengine generator set governor. Plus, protective relaying maynot be required under normal operation since the contact over-lap time is less than 100 milliseconds (consult your local utilityon protective relay requirements).Failure to synchronize indication and extended parallel timeprotection is built-in to all 7000 SERIES closed transition controls to prevent abnormal 2:Four pole, Closed Transition Transfer Switchrated 1000 amperes in Type 1 SERIESP ower switching SolutionsASCO ----150, 260, 400 --600, 800 1000,12001600, 2000630004000------18303030UL 1008 Withstand and Close-On RatingsWithstand and Close-On Ratings for all 7000 SERIESP roducts(1)(2)Notes: 1) All values are available symmetrical RMS amperes and tested in accordance with the withstand and close-on requirements of UL 1008.

7 See publication 1128 for more information on withstand and close-on ratings for asco Transfer Switches . 2) Application requirements may permit higher withstand ratings for certain size Switches . Contact asco for guidance if available short circuit current exceeds the WCRratings ) Any breaker ratings are based on cycles for 30 - 230 amp & 3 cycles for 260 - 4000 amps. Applicable to breakers with instantaneous trip ) Short time ratings are provided for applications involving breakers that do not have instantaneous trips for system ) Short time rating applicable to Transfer switch design ) Optional front connected service limited to 85,000 amps for specific and any breaker Transfer SwitchingASCO Non-Automatic Transfer Switches are electricallyoperated units which are operated with manual controlswitches mounted locally or at remote locations.

8 Sizes from 30 through 4000 amperes. Microprocessor based controller provides for additionof optional accessories. Controller prevents inadvertent operation under lowvoltage conditions. Low control circuit operating currents allow for longline runs between remotely mounted manual controlswitches and the Transfer switch. Source acceptability lights inform operator if sourcesare available to accept load. Standard inphase monitor can be activated fortransferring motor 4:Three pole Non-Automatic, electrically operated 400 ampere switch shown in Type 1 , 100, 125,150, 200230260, 400, 600260, 400, 600260, 400, 600800, 1000, 1200 1600, 2000530004000100,000200,000100,000200,00 0200,000200,000200,000200,000200,000200, 000200,000200,000200,000 JJJJLJLJLLLLL10,00010,00010,00035,00035, 00065,00050,000100,000100,000100,000N/AN /AN/AN/AN/AN/A36,000565,00065,00065,000 Short TimeWithstandRatings(4)Short TimeDuration(Cycles)Specific BreakerRating10,00022,00022,00042,00050, 00065,00065,000100,000100,000100,000 Max.

9 Fuse Typeampstypes602003006008006008006008001 600300040006000 Current - LimitingFuse RatingBypass SwitchesTransfer SwitchesSwitch Rating (Amps) 7000 SERIESP ower switching SolutionsASCO Any Breaker(3) RatingTestedVoltages480V480V480V600V480V 240V600V600V600V480 VAutomatic Transfer Bypass-Isolation SwitchingASCO Automatic Transfer & Bypass-Isolation Switches are available inopen transition, closed transition and delayed transition designs. Thebypass and isolation features allow Power Transfer Switches to be inspected, tested, and maintained without any interruption ofpower to the load. Available 150 to 4000 amperes. Allows bypass-isolation without load interruption. Bypass switch and Transfer switch have identical electrical ratings. Heavy duty mechanical interlocks prevent undesirable operation.

10 Bypass contacts carry current only during bypass mode. Transfer switch is drawout design for ease of maintenance. Bypass and isolation handles are permanently mounted. The bypassswitch has dead front quick-make, quick-break operation for transferring of loads between live sources. Bypass switch is fully rated for use as a manual 3-position Transfer switch. Bypass and isolation functions are simple, requiring a total of two operating handles. No toggle Switches , push buttons, selector Switches or levers arerequired for bypass-isolation operation. Mechanical indicators show bypass and Transfer switch positions. 600 -1200 ampere available in shallow depth, front connected orrear connected 5:Three Pole 7000 SERIESA utomatic Bypass-Isolation Transfer Switch Rated 1000 AmpsTransfer Switch Drawout Features (600-3000 amperes) Automatic secondary disconnectsremove all control Power as switch iswithdrawn.


Related search queries