BarlowINSULATING JOINTSM anufactured By IMAC Systems , Measurement and Control Systems90 MAIN ST. BOX 1605 TULLYTOWN, PA 19007 Distributed by: BOX 1605 TULLYTOWN, PA 190071-800-955-4 GAS (4427) Tel: (215) 946-2200 FAX: (215) 943-2984e-mail: Machined ComponentsFully Tested Ready For InstallationPrecision Assembly and TorquingGBC D E A F A E D CAForded Steel FlangesBAlloy Steel StudsCSteel Hex NutsDRecessed Steel WashersEDielectric WashersFDielectric SleevesGDielectric GasketsBarlowINSULATING JOINTSWhy Barlow Insulated Joints?1. Preassembly eliminates kits, saves on site labor2. Controlled assembly and pretesting eliminatesadjustments. Guarantees Mechanical design resists affects of stress andresulting insulation failure4.

Barlow INSULATING JOINTS Manufactured By IMAC Systems, Inc. International Measurement and Control Systems 90 MAIN ST. • P.O. BOX 1605 • TULLYTOWN, PA 19007

Tags:

  Walbro

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Barlow - IMAC Systems

1 BarlowINSULATING JOINTSM anufactured By IMAC Systems , Measurement and Control Systems90 MAIN ST. BOX 1605 TULLYTOWN, PA 19007 Distributed by: BOX 1605 TULLYTOWN, PA 190071-800-955-4 GAS (4427) Tel: (215) 946-2200 FAX: (215) 943-2984e-mail: Machined ComponentsFully Tested Ready For InstallationPrecision Assembly and TorquingGBC D E A F A E D CAForded Steel FlangesBAlloy Steel StudsCSteel Hex NutsDRecessed Steel WashersEDielectric WashersFDielectric SleevesGDielectric GasketsBarlowINSULATING JOINTSWhy Barlow Insulated Joints?1. Preassembly eliminates kits, saves on site labor2. Controlled assembly and pretesting eliminatesadjustments. Guarantees Mechanical design resists affects of stress andresulting insulation failure4.

2 Serviceability and maintenance greatly simplifiedDesigned to the highest possiblestandards including the following:Thicker dielectric sleeves (1/8") machined toprecise, close tolerance dimensions, bothlength and bolt holes line reamed to provideperfect alignment and close tolerancefit to the dielectric studs machined from Alloy Steel andheat treated to ASTM DesignationA-193-52T Grade B-7, resulting in superiorstrength and greater resistance to stressinduced nuts machined from Alloy Steel and heattreated to ASTM Designation A-194 Class machined steel washers, flat parallel, andcounterbored allowing for square alignment and clear-ance for the dielectric sleeves. The clearance preventsstress on the sleeves after torquing flange gasket precision cut for ideal fit withsmall projection into the stream to preventcontamination or bridging of the joint insidethe assembly with accurate torquingcarried out in stages followed by retorquingafter 24 for minimum resistance of 2,000,000ohms prior to packing in special gap sealed with epoxy resin toprevent contamination during postassembly handling.

3 (Below Ground Installation) (Type "AA" Test Box)Wire No. in (AWG)BARLOWTest StationModel TL-11 ALL WIRE USED IS SINGLECONDUCTOR, STRANDED,COPPER WITH 600 VOLT,TYPE "RR" (NEOPRENE) DIRECTBURIAL LENGTHS OF WIRES = 15 FEET. OPTIONAL LENGTHS PERCUSTOMER " ROAD BOXINSTALLED PRIOR TO TESTSTATION INSTALLATIONSTANDARD LENGTHS OF WIRES = 15 FEET. OPTIONAL LENGTHS PERCUSTOMER SPECIFICATIONS. Curb The Electrical Breakdown of Insulated Flanges1. Non-linear voltage currentcharacteristics; limitspotentially destructive voltagelevels but does not interferewith cathodic Nominal values - 50 ohms at250 volts - 30,000 ohms at3 Self-healing; able to survivemultiple Your choice of wire Designed for above or belowground Fiber-glass housings availablefor above ground Priced competitively withfusible or sacrificial voltagerelief Measurement and Control SystemsIMAC Systems , BOX 1605 TULLYTOWN, PA 190071-800-955-4 GAS (4427) Tel: (215) 946-2200 FAX: (215) 943-2984e-mail: Barlow ACCESSORIES1.

4 Ideal housing for Barlow "TMK"Surge Arrestors, Lightning Arrestors,terminal wiring boxes and electricalcontrol enclosures in highly corrosive These enclosures are molded from a special polyesterresin material which has excellent resistance and out-standing physical properties. The hinged cover is easlyremovable, and is attached to the body with internalhinges. Each cover has a neoprene gasket attached withoil-resistant adhesive. Cover screws are monel. Allenclosures have a grey finish inside and Drill holes, cut outs, floor flanges can be supplied atan extra These enclosures conform to the NEMA 4 standards for:dusttight, raintight, sleet-ice-resistant, rain-proof, water-tight,oil-tight and corrosion-resistant.

5 STANDARD SIZESE nclosure InsideDimensionsLength x Height x Width6" x 4 x 4 15/168" x 6 x 5 3/1610" x 6 x 5 11/1612" x8 x 6 11/16No. 6 Wire (AWG)Consult Factory for Details234681012141620248 10 1416 202223 1 1 2 1/82 7/162 2 7/833 3 4 8881212162020202424 5/8 7/811 1/81 1/81 1 3/81 1 5 66 88 7/89 1010 5/811 12 146 7 8 1011 12 1313 14 15 16 275598197280446568804110216112380 6 ! ""# $ % & ' (&!) % *& # %+ ! %# % ,-- &' *ID FOR STANDARD WALL PIPE **ID FOR EXTRA STRONG WALL PIPE (STD WALL AVAILABLE UPON REQUEST)23468101214162024308 1012 1517 20 2325 30 1/81 1 1 5/81 7/822 1/82 2 2 3888121216162020242428 5/85/85/8 7/8111 1/81 1/81 3/81 5/84 5 5 6 1/86 7 88 99 10 11 5 6 7899 10 11 11 1313 12 2139609515420733144057286612901770 6 !

6 " # $ % & ' (&!) % *& # %+ ! %# % .-- &' 24681012141620243091113 16192123 27 3238 111 1/81 1 1 3/81 1 1 7/82 1/8488812121216202028 5/85/8 7/87/811 1/81 1/84 3/84 5 5 66 1/86 6 7 8 95 6 7 8 8 9 10 10 11 5/812 10 14345786122178226280398595810 6 ! " # $ % & ' (&!) % *& # %+ ! %# % /0- &'