Example: tourism industry

Battery Range Summary - EnerSys - EMEA

Battery Range Summary Seismic Stand Configuration RESERVE. Visit us at POWER. The PowerSafe DDm Range offers an Features and Benefits Benefits of the Steel Container Design ideal solution for large capacity valve 100% out of the box initial Battery capacity Ease of installation. Simply set up rack and Proven VRLA AGM technology install modules regulated lead acid Battery requirements. Up to 2000 Ah in a single cell Uniform and consistent compression PowerSafe DDm's steel container design Stand design allows for maximum heat Designed-in thermal management allows concept, with its integral racking system, maximum air flow dissipation provides a cost effective Battery system Flexible configuration Certified to 1997 UBC Zone 4 to six high on with a compact, quick and simple DD

The PowerSafe® DDm range offers an ideal solution for large capacity valve regulated lead acid battery requirements. PowerSafe DDm’s steel container design concept, with its integral racking system,

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Battery Range Summary - EnerSys - EMEA

1 Battery Range Summary Seismic Stand Configuration RESERVE. Visit us at POWER. The PowerSafe DDm Range offers an Features and Benefits Benefits of the Steel Container Design ideal solution for large capacity valve 100% out of the box initial Battery capacity Ease of installation. Simply set up rack and Proven VRLA AGM technology install modules regulated lead acid Battery requirements. Up to 2000 Ah in a single cell Uniform and consistent compression PowerSafe DDm's steel container design Stand design allows for maximum heat Designed-in thermal management allows concept, with its integral racking system, maximum air flow dissipation provides a cost effective Battery system Flexible configuration Certified to 1997 UBC Zone 4 to six high on with a compact, quick and simple DDm125 sizes and eight high on all other Cell protected from damage during transport installation process.

2 Sizes Module design. 2 and 4 volt modules Installation available The PowerSafe DDm Battery system's Easy to install modules System can be configured 2, 3, 4 or 6 cells Flexible configuration - 2, 3, 4 or 6 cells wide in cutting-edge technology incorporates an wide in single cell modules; 2, 4 or 6 cells single cell modules or 2, 4 or 6 cells wide in enhanced cell design with thick positive wide in 2-cell modules for maximum flexibility 2-cell modules Easy installation plate for long life and a superior racking Total front access for easy maintenance Top termination supplied as standard system.

3 The welded/epoxy, dual pillar Floor anchoring - easy access during install, rack Clear flame retardant safety shields allow for can be set before stowing modules seal design provides a high integrity seal easy visual inspection without removal Top termination as standard - optional side and the large copper pillar design termination available enhances high rate performances. Construction Transition kits available Positive plate - Thick lead-tin-calcium Grounding kits available for bonding of all steel grids minimise corrosion and prolong life components Cells are encased in dedicated Negative plate - Balanced lead-calcium plates protective steel containers that maintain optimise recombination efficiency constant and uniform compression for AGM separator - Mechanically strong, low the life of the cell.

4 The easy to assemble electrical resistance, microporous glass fibre completely absorbs the electrolyte into its racking system provides total flexibility structure for system configuration and allows fast Container - Flame retardant polypropylene and simple installation, even in the most (UL94 V-0 28%). difficult locations. Container are single-piece construction Electrolyte - Dilute sulphuric acid Terminal pillar - Cast lead terminal. Threaded PowerSafe DDm, with its optimised copper insert, with large surface area, to provide recombination technology and extra thick maximum conductivity plates, provides excellent performance Pillar seal - Ring burn with secondary epoxy and service life across a wide Range of resin seal is 100% water bath tested in the factory and proven in service applications including Relief valve - Operates at 2-3 psi and is telecommunications, power complete with integral flame arrestor generation/distribution and UPS.

5 Battery Range Summary General Specifications Nominal Capacity (Ah) Nominal Dimensions (mm). Nominal Cells 10 hr rate Typical Internal Short Circuit PowerSafe DDm . Voltage per to Length Height Depth Depth Weight Resistance Current Battery Type (V) Module @ 20 C (container) (module) (kg) (micro-Omhs) (Amps). 2 DDm50-09 4 2 202 188 165 333 366 825 2527. 2 DDm50-13 4 2 303 265 165 333 366 550 2791. DDm50-17 2 1 404 176 165 333 366 413 5048. 2 DDm85-13 4 2 498 265 165 519 554 515 4049. 2 DDm85-15 4 2 582 303 165 519 554 441 4728.

6 DDm85-21 2 1 831 214 165 519 554 309 6748. DDm85-25 2 1 997 252 165 519 554 258 8081. DDm85-27 2 1 1080 271 165 519 554 238 8761. DDm85-33 2 1 1330 328 165 519 554 193 17803. DDm100-21 2 1 975 214 165 590 624 270 7722. DDm100-25 2 1 1170 252 165 590 624 225 9267. DDm100-27 2 1 1270 271 165 590 624 208 10024. DDm100-33 2 1 1560 328 165 590 624 169 12337. DDm125-25 2 1 1490 252 226 562 597 168 12411. DDm125-27 2 1 1610 271 226 562 597 155 13452. DDm125-33 2 1 1980 328 226 562 597 126 16548. Outline Drawings Container Depth Container Depth Height Height Module Depth Module Depth Length Length Battery Range Summary System Configurator Nominal Stack Length (mm) Typical Module Weight(1) (kg).

7 Nominal Nominal Nominal Cells Row Stack PowerSafe DDm Voltage per Height Depth 2 Wide 3 Wide 4 Wide 6 Wide Battery Type (V) module (mm) (mm) Module Module Module Module Unpacked Packed 2 DDm50-09 4 2 401(2) N/A 468 658 2 DDm50-13 4 2 477(2) N/A 620 887 DDm50-17 2 1 442 619 791 1145 2 DDm85-13 4 2 477(2) N/A 620 887 2 DDm85-15 4 2 515(2) N/A 696 1001 DDm85-21 2 1 517 732 944 1412 DDm85-25 2 1 594 846 1096 1640 DDm85-27 2 1 632 904 1173 1755 DDm85-33 2 1 746 1075 1401 2098 DDm100-21 2 1 517 732 944 1412 DDm100-25 2 1 594 846 1096 1640 DDm100-27 2 1 632 904 1173 1173 DDm100-33 2 1 746 1075 1401 2098 DDm125-25 2 1 622 871 1127 1668 DDm125-27 2 1 660 928 1203 1784 DDm125-33 2 1 774 1099 1432 2126 (1).

8 Includes hardware for calculating system weight (2). Standard top termination not available, stack length is with same side termination System Dimensions Formula System height = (row height x no. of cell high) + 229mm System length = stack length x no. of stacks System weight = module weight x no. of modules Example A: 24 x DDm85-21. 4 modules wide per stack x 6 modules high per stack Height Height System height = ( x 6) + 229mm = 1, System length = 944mm x 1 = 944mm System weight = x 24 = 1, Example B: 240 x DDm125-25.

9 4 modules wide per stack x 6 modules high per stack System height = ( x 6) + 229mm = 1, System length = 1127mm x (240 24) = 11,270mm System weight = x 240 = 29, Length Length Depth Depth Terminal Location Not all locations are possible for all configurations. EnerSys World Headquarters 2366 Bernville Road, Reading, PA 19605, USA Tel: +1-610-208-1991 / +1-800-538-3627. EnerSys EMEA EH Europe GmbH, L wenstrasse 32, 8001 Zurich, Switzerland EnerSys Asia 152 Beach Road, Gateway East Building Level 11, 189721 Singapore Tel: +65 6508 1780.

10 2014 EnerSys . All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates, except ISO, which is not the property of EnerSys . Subject to revisions without prior notice. EN-DDm-RS-004 - October 2014.