Example: barber

brand FS-90 Fire-Shield Compound Technical Information ...

ProForm brand FS-90 Fire-Shield Compound (Through-Penetration FIre Stop) Technical Information :800-NATIONAL 800-628-4662 DescriptionProForm brand Fire-Shield 90 Compound is a setting/hardening type Compound designed to provide protection in fire-stopping penetrations through fire rated partitions or assemblies in both new and retrofit UsesAPPLICATIONSM eets multiple standards to qualify as UL Listed to use: in fire and smoke-stop; for through-wall and floor penetrations; for head of Blocks fire and smoke - dries red for easy identification. Saves money - more economical and less waste than caulking tube products. Reduces waste - mix only what you need for the RecommendationsTo ensure the best results, use only National Gypsum products together in your construction systems.

ProForm® brand FS-90 Fire-Shield ® Compound (Through-Penetration FIre Stop) Technical Information: 800-NATIONAL 800-628-4662 Description ProForm® brand Fire-Shield 90 Compound is a setting/hardening type compound designed to provide protection in fire-stopping

Tags:

  Compound

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of brand FS-90 Fire-Shield Compound Technical Information ...

1 ProForm brand FS-90 Fire-Shield Compound (Through-Penetration FIre Stop) Technical Information :800-NATIONAL 800-628-4662 DescriptionProForm brand Fire-Shield 90 Compound is a setting/hardening type Compound designed to provide protection in fire-stopping penetrations through fire rated partitions or assemblies in both new and retrofit UsesAPPLICATIONSM eets multiple standards to qualify as UL Listed to use: in fire and smoke-stop; for through-wall and floor penetrations; for head of Blocks fire and smoke - dries red for easy identification. Saves money - more economical and less waste than caulking tube products. Reduces waste - mix only what you need for the RecommendationsTo ensure the best results, use only National Gypsum products together in your construction systems.

2 We do not recommend mixing our products with other brands. All National Gypsum texture products are formulated without asbestos and comply with Consumer Product Safety TEXTURES ON GYPSUM BOARDAll surfaces, including joint-treated areas, must be smooth, clean and dry. First, apply a coat of sealing primer. Allow primer to dry thoroughly, and maintain adequate drying conditions after application. Primer helps to minimize sagging of gypsum board and discoloration or difference in the sheen on the ceiling surface. Add dry texture to water. Use a piston pump or Mono-type pump with a texture gun. (Minimum 3/4 in. or mm Material Hose.) A hopper-type gun with adequate air supply is also suitable. Typical coverage is 8-10 sq.

3 Ft. per lb. for aggregated and 10-30 sq. ft. per lb. for non-aggregated textures. Mask appropriate areas before spraying and promptly remove overspray from unprotected surfaces afterward. Follow the instructions of the spray equipment manufacturer for adjusting controls and cleaning. If a second coat is desired, allow the first coat to dry decorate gypsum board ceiling surfaces with water-thinned spray texture, apply 1/2 in. ( mm) or 5/8 in. ( mm) thick and perpendicular to the framing. Framing should not exceed 16 in. (406 mm) for Gold Bond brand 1/2 in. ( mm) Gypsum Board and 24 in. (610 mm) for 1/2 in. ( mm) High StrengthTM Ceiling Board and Gold Bond brand 5/8 in. ( mm) Gypsum TEXTURES ON CONCRETEA llow concrete to cure for at least 28 days.

4 Clip protruding wire ends and spot with rust-inhibitive primer. Remove all form of oil, grease and dirt, or any loose or water-soluble material. Grind down any form ridges, and level any remaining unevenness with ProForm brand Quick SetTM Joint Compound . Apply a coat of alkali-resistant sealing primer over the entire surface. For More InformationARCHITECTURAL SPECIFICATIONSN ational Gypsum Company s CSI Master Format 3-part guide specifications are downloadable as editable Microsoft Word documents at: Information AND UPDATESFor the latest Technical Information and updates, call NGC Construction Services: 1-800-NATIONAL (628-4662) or visit our website: 84 00/NGC Job Name: Contractor: Date:Submittal Approvals: (Stamps or Signatures)1 Technical DATAPHYSICAL PROPERTIESPROFORM FS-90 Fire-Shield CompoundPackaging Approx.

5 Coverage Mixing Bag:25 lbs. ( kg) 850 cu. in. 12 - 13 pts. ( - L) clean, room temperature, drinkable water per less than a full bag is used, mix at a ration of 2 parts dry powder to 1 part Fire-Shield Compound Fire-Resistance RatingsPenetrating ItemAnnular SpaceHole Size RatingT RatingUL System Wall SystemsMin. 10-33% Max. Fill No. 24 AWG CableMin. 1/4" ( mm) Max. 4-1/2" (114 mm)6" (152 mm)2 " dia. (102 mm) EMT Pipe or Steel PipeMin. 1/4" ( mm) Max. 2-1/2" ( mm)7" (178 mm)2 " dia. ( mm) Copper PipeMin. 1/4" ( mm) Max. 2-1/2" ( mm)6" (152 mm)2 Wall SystemsSteel Sleeve, Nom. 6" dia. (152 mm) or Smaller Electrical Metallic Tubing, Conduit or Pipe Schedule 40 (or Heavier)Max. 1/4" ( mm)6" (152 mm)3 Pipe, Nom.

6 4" dia. (102 mm) or Smaller Schedule 40 (or Heavier) Min. 1/2" ( mm) Max. 3" ( mm)8" (203 mm)3 Fill No. 24 AWG Cables, Nom. 6" dia. (152 mm) Metallic Sleeve (Optional)Min 1/2" ( mm) Max. 3-1/2" ( mm)6" (152 mm)3 in accordance with the standard ANSI/UL1479and ASTM E8142 PARTITION / DECK INTERSECTION SYSTEMSD escriptionTest Reference1-Hour Partition/Fluted Deck JunctureWHI495-P5V10672-Hour Partition/Fluted Deck JunctureWHI495-P5V10681-Hour Deflection Track/ Fluted Deck JunctureWHI495-P5V10632-Hour Deflection Track/ Fluted Deck JunctureWHI495-P5V10642001 Rexford Road Charlotte, NC 28211(704) Rev. 12/172