ZELIO-TIME TimersRE7, RE8, and RE9 File 9050 CONTENTSD escriptionPageRE7 Application Data .. 2RE7 Multifunction Timers .. 6RE7 On Delay Timers .. 8RE7 On Delay and Off Delay Timers .. 10RE7 Off Delay Timers .. 12RE7 Interval Timers .. 14RE7 Repeat Cycle Timers .. 16RE7 Star-Delta Timers .. 18RE7 Dimensions and Wiring .. 20 21RE8 Timers .. 22RE9 Timers .. 30 Catalog04 Courtesy of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) Timers - RE7 Application Data 1993-2004 schneider Electric All Rights Reserved206/2004 The RE7 timers, with only 23 Catalog numbers, covers most timing timers offer multi-range timing from 50 ms to 300 are models combine several different functions: multifunction products have a transparent cover on the front to avoid any involuntary intervention on the measurement.

ZELIO-TIMETM Timers - RE7 Application Data 3 06/2004 © 1993-2004 Schneider Electric All Rights Reserved For 0.1 A, Curve 1 indicates a durability of approximately 1 ...

Tags:

  Schneider

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Catalog 04 - Steven Engineering

1 ZELIO-TIME TimersRE7, RE8, and RE9 File 9050 CONTENTSD escriptionPageRE7 Application Data .. 2RE7 Multifunction Timers .. 6RE7 On Delay Timers .. 8RE7 On Delay and Off Delay Timers .. 10RE7 Off Delay Timers .. 12RE7 Interval Timers .. 14RE7 Repeat Cycle Timers .. 16RE7 Star-Delta Timers .. 18RE7 Dimensions and Wiring .. 20 21RE8 Timers .. 22RE9 Timers .. 30 Catalog04 Courtesy of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) Timers - RE7 Application Data 1993-2004 schneider Electric All Rights Reserved206/2004 The RE7 timers, with only 23 Catalog numbers, covers most timing timers offer multi-range timing from 50 ms to 300 are models combine several different functions: multifunction products have a transparent cover on the front to avoid any involuntary intervention on the measurement.

2 This cover can be sealed. RE7RB MW: Peak current when switched on = 1 A/30 DataConforming to StandardsIEC 61812-1, EN 61812-1 Product Certifications Ambient Air TemperatureAround the DeviceStorage-40 to 185 F (-40 to + 85 C)Operation-4 to 140 F (-20 to + 60 C)Permissible Relative Humidity RangeConforming to IEC 60721-3-315 to 85% Environmental Class 3K3 Vibration ResistanceConforming to IEC 60068-2-6, 10 to 55 Hza = msShock ResistanceConforming to IEC 60068-2-2715 gn - 11 msDegree of ProtectionHousingIP 50 TerminalsIP 20 Degree of PollutionConforming to IEC 60664-13 Ue = 300 VOvervoltage CategoryConforming to IEC 60664-1 III Ue = 300 VRated Insulation VoltageBetween contact circuit and power supply or between contact circuit and control inputsConforming to IEC250 VConforming to UL and CSA300 VTest Voltage forInsulation TestsDielectric testUL and CSA 2200 Vac.

3 IEC 2000 VacShock wave4800 VVo l t ag e L i m it sPower supply UcDisconnection ValuePower supply circuit> UcMounting Positionwithout DeratingIn relation to the normal vertical mounting positionAny positionConnection Maximum Cross-Section Stranded wire without cable end 2 # 14 AWG (2 x mm2)Stranded wire with cable end2 # 16 AWG (2 x mm2)Tightening lb-in ( N m)Immunity from Electromagnetic Interference (EMC) (Application Class 2 Conforming to EN 61812-1)Electrostatic DischargeConforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)Electromagnetic FieldsConforming to IEC 61000-4-3 Level 3 (10 V/m)Rapid TransientsConforming to IEC 61000-4-4 Level 3 (2 kV output power, 1 kV control)Shock WavesConforming to IEC 61000-4-5 Level 3 (2 kV common mode, 1 kV differential mode)Radiated and Conducted EmissionsCISPR11 Group 1 Class ACISPR22 Class AConsumptionConsumption24 Vac48 Vac110 Vac 240 Vac 24 Vdc48 Vdc110 Vdc240 VdcVAWRE7 RE7 12BU and RE7 RE7 MW File E164353 CNN NKCRFile LR 89150 Guide 3211 07 GLCourtesy of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area.

4 (800) Timers - RE7 Application Data306/2004 1993-2004 schneider Electric All Rights ReservedFor A, Curve 1 indicates a durability of million operating the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles, as indicated by curve cos = : k = electrical durability therefore becomes: ( x 106) operating cycles x = 900,000 operating cycles. The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product operation or life.

5 For information on the listed warranty offered on this product, refer to the terms and conditions of sale found in the Delay SpecificationsSetting AccuracyAs % of the full scale value 10 %Repeat Accuracy %Influence of VoltageIn the voltage range, Un< %/V Influence of Temperature< %/ KImmunity to Micro-Breaks3 msMinimum Control Pulse 20 ms (except RE7RB1 MW: 1 s)Reset Time50 msOutput Circuit SpecificationsMechanical Durability In millions of operating cycles20 (10 for RE7RB1 MW) Current Limit Ith8 ARated Operational Limits at 70 C24 V115 V250 VConforming to IEC 60947-5-1/1991 and VDE 0660AC-15 N/C contact3 A3 A3 AAC-15 N/O contact5 A5 A5 ADC-13 N/O contact2 AUL and CSA Current RatingsResistive Rating5 ANEMA / UL B300 Inductive Rating3600 VA Make Rating360 VA Break Rating5 A CarryMinimum Switching Power12 V/10 mA Contact MaterialSilver Nickel 90/10 Remote Control Input SpecificationsSignal Delivered by Y1-Z2, X1-Z2, X2-Z2 Control InputsNo galvanic insulation between these inputs and the power supplySwitching current< 1 mAMaximum distance164 ft (50 m)

6 Compatibility3/4-wire PNP and NPN Telemecanique sensors or other sensors without an internal loadPotentiometer for Connectionbetween terminalsZ1-Z2, Z3-Z2 TypeLinear at 20 %Resistance47 20 % k WMaximum distance82 ft (25 m) per shielded cable: shielding linked to terminal 1 AC LoadElectrical durability of contacts on resistive load in millions of operating 2 Reduction factor k for inductive loads (applies to values taken from the durability curve above)Example:An LC1F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to and cos = Load Load Limit L/R = 20 ms2 L/R with load protection diode3 Resistive loadRE7K+ Courtesy of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) Timers - RE7 Timing Functions 1993-2004 schneider Electric All Rights Reserved406/2004 Timing FunctionsOperating DiagramOperating PrincipleOn-Delay TimerSupply Voltage Output ContactSPDT (C/O)Timing starts when the timer is energized.

7 When the set time delay (ta) has elapsed, the output contact closes. When the timer is de-energized, the output contact returns to its initial position. The output contact does not close if the duration of the control instruction is less than the set time can also be started by opening of a external contact (models with remote control).Off-Delay TimerSupply Voltage Output ContactSPDT (C/O)Energization of the timer or closing of the control contact (models with external control) causes the output contact to close instantaneously. Timing starts when the timer is de-energized or when the control contact opens. When the set time delay (tr) has elapsed, the output contact returns to its initial position.

8 If the energization time or closing time of the control contact is less than the minimum time specified, the timing period does not and Off-Delay TimerSupply Voltage Output ContactSPDT (C/O)This function is a combination of the On and Off delay functions. The timing cycle must be controlled by an external On and Off delays are On and Off delays are adjusted by 2 different Timer (Pulse On Energization)Supply VoltageOutput ContactSPDT (C/O)Energization of the timer causes the output contact to close instantaneously and start the timing period. The output contact returns to its initial position when the set time delay (t) has elapsed or if the supply is cut off before the end of the timing with Pulse On De-Energization or On Opening of a External Control ContactSupply VoltageOutput ContactsSPDT (C/O)De-energization of the timer or opening of the external control contact (depending on model) causes the output contact to close instantaneously and start the timing period.

9 When the set time delay (t) has elapsed, the contact returns to its initial Cycle Timer (Flashing Timer)Supply VoltageOutput ContactSPDT (C/O)Energization of the timer starts the flashing period and causes the output timer to start the flashing cycle. When the timer is de-energized, the contact returns to its initial Flashing TimerThe timer flashes with a symmetrical On/Off Flashing TimerThe On and Off flashing timers are adjusted by 2 different for Star-Delta StartersSupply VoltageOutput ContactsEnergization of the timer causes the star contactor to close instantaneously and starts the timing period. When the set time delay (t) has elapsed, the star contactor returns to its initial position and the delta contactor closes, after a breaking time sufficient for the of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) Timers - RE7 Additional Functions506/2004 1993-2004 schneider Electric All Rights Reserved Please consult your Regional Sales Office.

10 1C/O = SPDT = 2 C/O = DPDT = Additional FunctionsExternal Control of Starting: Opening of an external contact connected to the timer starts the timing period. Closing of this contact resets the External Control of Timing: Closing of an external contact connected to the timer allows the timing period to be interrupted. The time elapsed is memorized. Timing restarts as soon as the contact opens. This type of control enables the totalizing function to be Adjustment of the Time Delay: One or more external potentiometers can be used for remote adjustment of the timing period or periods. Output Multifunction TimerSee PageSolid StateRE9TA321 C/ORE7TL OR RE8TA8 or 242 C/ORE7TP81 C/ORE7TM8 Solid StateRE9RA321 C/ORE7RB11 or RE8RB12 or 242 C/ORE7RL122 C/ORE7RB13121 C/ORE8RA241 C/ORE7RA and RE7RM122 C/ORE7MA13101 C/ORE7MA11101 C/ORE7MV101 C/ORE7PE or RE8PE14 or 262 C/ORE7PP141 C/ORE8PT262 C/ORE7PD141 C/ORE7PM142 C/ORE8PD261 C/ORE7CL or RE8CL16 or 242 C/ORE7CP161 C/ORE7CV161 C/ORE8YG262 C/ORE7YA and RE7YR181 N/C + N/ORE8YA26 Solid StateRE9MS331 C/ORE7ML62 C/ORE7MY13MW62 C/ORE7MY13BU6 Courtesy of Steven Engineering , Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area.