Example: stock market

Chapter 7 Non-linear Seismic Response of Structures

238 Chapter 7 Non-linear Seismic Response of Structures Introduction As per the conventional earthquake-resistant design philosophy, the Structures are designed for forces, which are much less than the expected design earthquake forces. Hence, when a structure is struck with severe earthquake ground motion, it undergoes inelast ic de format ions. Even though the structure may not collapse but the damages can be beyond repairs. In reinforced cement concrete (RCC) Structures , a structural system can be made ductile, by providing reinforcing steel according to the IS:13920-1993 code.

238 Chapter 7 Non-linear Seismic Response of Structures . 7.1 Introduction . As per the conventional earthquake-resistant design philosophy, structuresthe are designed

Tags:

  Linear, Seismic, Structure, Response, Linear seismic response of structures

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Chapter 7 Non-linear Seismic Response of Structures

1 238 Chapter 7 Non-linear Seismic Response of Structures Introduction As per the conventional earthquake-resistant design philosophy, the Structures are designed for forces, which are much less than the expected design earthquake forces. Hence, when a structure is struck with severe earthquake ground motion, it undergoes inelast ic de format ions. Even though the structure may not collapse but the damages can be beyond repairs. In reinforced cement concrete (RCC) Structures , a structural system can be made ductile, by providing reinforcing steel according to the IS:13920-1993 code.

2 A sufficiently ductile structural system undergoes large deformations in the inelastic regio n. In order to understand the complete behaviour of Structures , time history analysis of different Single Degree of Freedom (SDOF) and Multi Degree of Freedom (MDOF) Structures having Non-linear characteristics is required to be performed. The results of time history analysis, Non-linear analysis of these Structures will help in understanding their true behavior. From the results, it can be predicted, whether the structure will not collapse / partially collapse or totally collapse.

3 In this Chapter , the modeling of SDOF and MDOF Structures having Non-linear characteristics for Seismic Response analysis is carried out. The push over analysis of the RCC building is also presented. Non-linear Force-Deformation Behavior The structural systems which have linear inertia, damping and restoring forces, are analysed by linear methods. Whenever, the structural system has any or all of the three reactive forces ( inertia, damping and stiffness) having Non-linear variation with the Response parameters, namely displacement, velocity, and acceleration; a set of Non-linear differential equations is evolved.

4 To obtain the Response , these equations need be solved. The most common non-linearity is the stiffness and the damping non-line arit y. The stiffness non-linearity co mpr ises of two type s namely the geometric non-linearity and the material non-linearity. For the material non-linearity, restoring action shows a hysteretic behavior under cyclic loading. For the geometric non-linearity, no such hysteretic behavior is exhibited. During unloading, the load deformation path follows that of the loading.

5 Figure (a) shows 239 the case of load deformation behavior of the non-hysteretic type. Figure (b) shows the hysteretic behavior of a Non-linear restoring force under cyclic loading (material non-linearity). Damping non-linearity may be encountered in dynamic problems associated with structural control, offshore Structures , and aerodynamics of Structures . Most of the damping non-linearities are of a non-hysteretic type. Most Structures under earthquake excitation undergo yielding.

6 Hence, it is necessary to discuss material non-linearity exhibiting hysteretic behavior. For structural systems having linear behaviour (when subjected to weak ground mot ions) of inertial forces, spring elastic forces and linear damping characteristics, linear methods of analysis can be employed. Displacement, velocity and acceleration are important Response parameters of any structural system. When any or all of the reactive forces, viz. inertia force / spring force or damping force has nonlinear variation with the Response parameters, the analysis involves Non-linear differential equations.

7 Solution of these equations will give the Response of the system. The popular method to obtain the Response is Newmark s Beta method. Figure (a) Non-linear restoring force for geometrical non-linearity (non-hysteretic type) and (b) Non-linear restoring forces (hysteretic type) Displacement Force Displacement Force 240 7. 3 Non-linear Analysis of SDOF system Consider a SDOF system having Non-linear damping and stiffness characteristics as shown in the Figure Figure Non-linear SDOF system and its free body diagram.

8 For the SDOF system, the equation of motion in the incremental form is expressed as ii ti tiggmx c x k xmx + + = ( ) where m is the mass of the SDOF system, tc is the initial tangent damping coefficient and tkis the initial tangent stiffness at the beginning of the time step, respectively. The so lution of the equation of motion for the SDOF system is obtained using the numerical integration technique.

9 The incremental quantities in the equation ( ) are the change in the responses from time ti to ti+1 given by 1111 1 iiiiiiiiii iiii igg gxxxxxxxxxt ttxx x+++++ = = = = = ( ) Assuming the linear variation of acceleration over a small time interval, it the incremental acceleration and velocity (refer Section Newmark s Beta Method) are expressed as 266 3iiiiiixxxxtt = ( ) gx m kt ct x ()gmx x+ sF dF m 241 3 3 2iiiiiitxxxxt = ( ) Substituting ix and ix in equation ( ) and solving for theix will give effieffpxk = ( ) where effp and effkare the incremental force and incremental stiffness during the ith time step respectively expressed as.

10 6 2 22iieffgtitiitpmxm cxmcxt = +++ + ( ) 263 effttiikmcktt= ++ ( ) Knowing theix , determine ix fro m equa t ion ( ). At time, t = ti+1, the displacement and velocity can be determined as 11 i iii iix xxx xx++= + = + ( ) The acceleration at time, t = ti+1 is calculated by considering equilibrium of the system (refer Figure ) to avoid the accumulation of the unbalanced forces 1 1111 F i iiig dsxmxFm++++ = ( ) where 1 Fid+ and 1isF+ denote the damping and stiffness/restoring force at time, ti+1, respectively.


Related search queries