Example: bachelor of science

Circuit Breaker Panelboards - Steven Engineering

I-Line Circuit Breaker PanelboardsClass 2110 CONTENTSD escriptionPageProduct Description .. 3 Features and Benefits .. 7 Accessories .. 8 General and Application Information .. 9 Dimensions .. 14 Replacement Parts.. 24 Catalog05I-Line Circuit Breaker PanelboardsProduct Description302/2005 1998 2005 Schneider Electric All Rights ReservedPRODUCT DESCRIPTIONS quare D -brand I-Line Circuit Breaker power distribution Panelboards are for use on AC or DC systems. The panels, labeled cULus (compliance to UL and CSA standards certified by UL) are also Underwriters Laboratories (UL ) Listed under File E33139. The following are suitable for use as service entrance equipment: All main Circuit Breaker Panelboards . All main lugs Panelboards with branch-mounted, back-fed main Circuit Breaker . (For Canadian MLO service entrance, use HCP-SU and HCR-U only).

I-Line® Circuit Breaker Panelboards Class 2110 CONTENTS Description Page Product Description ...

Tags:

  Breaker, Circuit, Panelboard, Circuit breaker panelboards

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Circuit Breaker Panelboards - Steven Engineering

1 I-Line Circuit Breaker PanelboardsClass 2110 CONTENTSD escriptionPageProduct Description .. 3 Features and Benefits .. 7 Accessories .. 8 General and Application Information .. 9 Dimensions .. 14 Replacement Parts.. 24 Catalog05I-Line Circuit Breaker PanelboardsProduct Description302/2005 1998 2005 Schneider Electric All Rights ReservedPRODUCT DESCRIPTIONS quare D -brand I-Line Circuit Breaker power distribution Panelboards are for use on AC or DC systems. The panels, labeled cULus (compliance to UL and CSA standards certified by UL) are also Underwriters Laboratories (UL ) Listed under File E33139. The following are suitable for use as service entrance equipment: All main Circuit Breaker Panelboards . All main lugs Panelboards with branch-mounted, back-fed main Circuit Breaker . (For Canadian MLO service entrance, use HCP-SU and HCR-U only).

2 All main lugs Panelboards with six disconnects or less. A solid neutral that is insulated, but may be bonded to the box with a grounding strap. Service entrance Panelboards meeting the requirements of CSA are available in Canada factory-assembled Circuit Breaker Panelboards are available as 225 1200 A main lugs only and 100 1200 A main Circuit breakers. I-Line Panelboards are designed to accept the following Circuit breakers: FY, FA, FH, FC, FJ, FK, FI, HD, HG, HJ, HL, QB, QD, QG, QJ, QO, KA, KH, KC, KI, JD, JG, JJ, JL, LA, LH, LC, LI, LE, LX, LXI, MA, MH, MG, MJ, PG, PJ, PK*, PL, RG, RJ, RK*, and RL.* Canada Circuit Breaker Panelboards are designed, manufactured, and tested to comply with the following standards:ServiceI-Line Circuit Breaker Panelboards can be used on the following system voltages: 120/240 VAC; 1-phase, 3-wire 240 VAC; 1-phase, 2-wire 240 VAC; 3-phase, 3-wire 240 VAC Ground, B-phase; 3-phase, 3-wire 208Y/120 VAC; 3-phase, 4-wire 480Y/277 VAC; 3-phase, 4-wire 480 VAC; 3-phase, 3-wire 600Y/347 VAC; 3-phase, 4-wire 600 VAC; 3-phase, 3-wire 125/250 VDC; 3-wire 250 VDC; 2-wireStandardDescriptionUL 50 Standard for enclosures for electrical equipmentUL 67 Standard for panelboardsCSA , Nos.

3 29 and 94 1989 Standard for Panelboards and enclosed panelboardsNFPA 70 National Electrical Code (NEC)NEMA PB 1 Standard for panelboardsW P 115C Type 1 Class 1 Specification for Circuit Breaker panelboards2000 IBCUS standard for seismic requirements1995 NBCCC anadian standard for seismic requirementsType HCR-U 1200 A Main Circuit BeakerType HCR-U 1200 A Main Circuit BeakerI-Line Circuit Breaker PanelboardsProduct Description402/2005 1998 2005 Schneider Electric All Rights Reserved panelboard TypesPanelboard TypeMaximum Mains AmpacityMaximum Branch Circuit Breaker Frame Size Enclosure Dimensions Main LugsMain Circuit BreakersLeftRightWidthIN (mm)DepthIN (mm)HCN600 A400 AFA, QB, HDFA, QB, HD26 (660) (165)HCM800 A800 AJDJD32 (813) (210) (241)HCP-SU800 A800 A MG, PGNone26 (600) (241)HCP1200 A800 A MG, PGJD42 (1067) (241)HCR-U1200 A1200 A RGJD44 (1118) (241) For a complete listing of applicable Circuit Breaker types, refer to the dimensions section.

4 Refer to the Dimensions section for standard panelboard heights. Available as a main Circuit Breaker panelboard when provided with a branch mounted back-fed main Circuit HCP 600 A Main Circuit BreakerType HCP-SU800 A Main Circuit BeakerType HCM 400 A Main LugsI-Line Circuit Breaker PanelboardsProduct Description502/2005 1998 2005 Schneider Electric All Rights ReservedType 3R, 5, and 12 EnclosuresEnclosure TypesTypesEnvironmentsProvides Protection AgainstType 1 IndoorContact with the enclosed equipmentType 2 IndoorFalling water and dirtType 3 ROutdoorFalling rain, sleet; undamaged by iceType 4/4X StainlessIndoor/OutdoorCorrosion, hose-directed water, dustType 5 IndoorSettling dust, falling dirt, dripping liquidsType 12 IndoorCirculating dust, falling dirt, dripping liquidsFronts:HCN, HCM, HCP, HCP-SU, and HCR-U surface and flush trims available as four-piece construction, standard (door not included).

5 An optional four-piece trim with door is also 1 EnclosuresFinished with gray-baked enamel electrodeposited over cleaned phosphatized steel (ANSI 49).Directory card holders provided with all :Galvanized steel in 26, 32, 42, and 44-inch (660, 813, 1067, and 1118 mm) endwalls without 3R, 5, and 12 EnclosuresGasketed door with vault handle and directory card and side gutter drain screw for Type with gray-baked enamel electrodeposited over cleaned phosphatized steel (ANSI 49).Type 4X Enclosures (Factory-Assembled Only)Corrosion-resistant, fiberglass-reinforced and door with trunk card located on inside of 1 and 2 Enclosure with Optional DoorFlush Lock used on HCN, HCM, and HCP-SU Types 1 and 2 Fronts(Catalog No. PK4FL)Sliding Vault Lock used on HCN, HCP, and HCR-U Types 1 and 2 Fronts (Catalog No.)

6 PK5FL)Vault Handle used on all Type 3R, 5, and 12 Enclosures (Catalog No. PK4 NVL)Type 3R, 5, and 12 EnclosuresI-Line Circuit Breaker PanelboardsProduct Description602/2005 1998 2005 Schneider Electric All Rights ReservedMain Breaker Panelboards Accept a maximum 1200 A, 80% or 100% rated main Breaker . Available factory-assembled or merchandised.* Factory-assembled main Circuit Breaker interiors are available bottom-feed or top-feed. Suitable for use as service entrance equipment, US and Canada. Accept plug-on I-Line Circuit breakers. Available with a short Circuit current rating (SCCR) up to 200 kA maximum (100 kA @ 600 VAC) when supplied by an I-Limiter Circuit Breaker . Available with a silver-plated or tin-plated copper bus, or tin-plated aluminum bus. Solid neutral is mounted in the mains compartment with the main Circuit Breaker .

7 Merchandised (RTA in Canada) main Circuit Breaker Panelboards are provided bottom-feed as standard.* Ready-to-Assemble (RTA) in CanadaMain Lugs Only Panelboards Available with main lug only interiors rated up to 1200 A. Available factory-assembled or merchandised (RTA in Canada). Suitable for use as service entrance equipment when provided with a main Circuit Breaker , US and Canada. Accept plug-on I-Line Circuit breakers. Available with a short Circuit current rating (SCCR) up to 200 kA maximum (100 kA @ 600 VAC) when supplied by an I-Limiter Circuit Breaker . Available with a silver-plated or tin-plated copper bus, or tin-plated aluminum bus. Solid neutral is mounted in the mains compartment with the main lugs. Hinged cover, isolated main lugs compartment. Main lug interiors are available as top-feed or Neutral Mounts in main lug or main Circuit Breaker compartment.

8 Does not take up interior Circuit Breaker mounting space. UL/CSA Listed for use with Al or Cu conductors. Copper or aluminum neutral available. 200% rated neutral available as a factory-assembled Circuit Breaker and Solid Neutral Compartment (Canada service entrance not shown)Main Lug and Solid Neutral CompartmentTypical Solid NeutralMain neutral lugFull capacity bonding strap for use on service entrance applicationsNeutral with C/T for Use on HCR-U When Ground-Fault Protection is Required (Catalog No. HCR12 SNCT)I-Line Circuit Breaker PanelboardsFeatures and Benefits702/2005 1998 2005 Schneider Electric All Rights ReservedFEATURES AND BENEFITSF eatured below are just a few of the many features and benefits of Square D-brand I-Line Circuit Breaker BreakersI-Line Panelboards are available with a complete line of thermal magnetic, Micrologic , and electronic Circuit breakers.

9 The I-Line Circuit breakers, with their exclusive plug-on connection design provide superior reliability and performance Breaker Mounting 15 1200 A frame Circuit breakers require only a screwdriver and are ratcheted firmly onto the bus stack. They are secured in place by a screw. The connectors are an integral part of the I-Line Circuit Breaker eliminating the assembly of connectors to the bus bar. Pre-assembled hardware means reduced installation time. The unique line side connection requires no routine maintenance. I-Line Bus Structure and Circuit Breaker MountingPush-to-TripPush-to-trip is a standard feature on all I-Line Circuit breakers. It is useful for checking Circuit Breaker operation and for testing auxiliary devices. The Circuit Breaker is mechanically tripped by pressing the push-to-trip button in the Circuit Breaker ConnectionsAll Circuit Breaker connections are blow-on type.

10 Under high-level short Circuit conditions, the magnetic forces developed tend to draw the connector jaws together, gripping the I-Line bus bar more MountingBus phase insulators interlock with the Circuit Breaker insulating shroud and provide high dielectric strength between the bus breakers on right-hand side of the bus structure are completely independent of position and frame size of those on left-hand shroud keys into slots in bus support base. Aligns and supports line end of Circuit polyester insulators provide continuous bus bar Breaker connectors are shrouded and braced in molded protective insulator. Circuit Breaker jaws are lubricated and pre-set at the factory and require no Breaker mounting bracket an integral part of each Circuit Breaker ; securely supports and aligns load end of Circuit channels provide additional support for insulator bracing ConnectionsI-Line Circuit Breaker PanelboardsFeatures and Benefits802/2005 1998 2005 Schneider Electric All Rights ReservedShort Circuit Current Rating (SCCR) SCCR is equal to the lowest interrupting capacity of a branch or main Circuit Breaker installed in the panelboard .


Related search queries