Example: tourism industry

Configuration and Use Manual - Emerson

Configuration and Use ManualP/N MMI-20012741, Rev. ABJanuary 2021 Micro Motion Model 2200S TransmittersConfiguration and Use Manual 2021, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective and Use ManualiContentsChapter 1 Before You Begin .. this Manual .. your model number .. version information .. tools.. documentation .. Motion customer service .. 3 Chapter 2 Quick Start.

Configuration and Use Manual P/N MMI-20012741, Rev. A September 2008 Micro Motion® Model 2200S Transmitters Configuration and Use Manual

Tags:

  Manual, Configuration, Configuration and use manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Configuration and Use Manual - Emerson

1 Configuration and Use ManualP/N MMI-20012741, Rev. ABJanuary 2021 Micro Motion Model 2200S TransmittersConfiguration and Use Manual 2021, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective and Use ManualiContentsChapter 1 Before You Begin .. this Manual .. your model number .. version information .. tools.. documentation .. Motion customer service .. 3 Chapter 2 Quick Start.

2 Overview and flowchart .. worksheet .. flowcharts .. II menus .. menus .. menus .. 17 Chapter 3 Getting Ready to Configure .. power .. up and making an administrative connection .. with the mA output scale .. the mA measurement point .. between mA output scales .. tips and tricks .. values and ranges .. factory Configuration .. and reporting options for process variables .. 29 Chapter 4 Configuring Process Measurement .. the flowmeter .. general flow parameters .. direction .. damping.. mass flow measurement .. flow measurement unit .. flow cutoff .. a special unit for mass flow .. 38iiMicro Motion Model 2200S volume flow measurement.. flow type .. flow measurement unit.

3 Gas properties for GSV flow measurement .. or GSV flow cutoff .. a special unit for volume or GSV flow .. density measurement .. measurement units .. cutoff .. damping .. flow parameters .. temperature measurement .. measurement units .. damping .. pressure compensation .. correction factors .. procedure .. and volume measurement .. with the Added Damping parameter .. 50 Chapter 5 Configuring Operational Parameters .. the display .. period .. language .. variables and display precision .. and disabling display functions .. fault handling .. alarm severity .. measured value (LMV) timeout .. sensor parameters.. device parameters .. 59 Chapter 6 Integrating the Meter with the Control System.

4 The mA output .. variable .. output scale (LRV and URV) .. cutoff .. damping .. output fault action and fault value .. digital communications .. communications fault action .. current mode .. , SV, TV, and QV assignments .. mode .. 69 Configuration and Use ManualiiiContentsChapter 7 Testing and Moving to Production .. zero .. for zero .. the zero procedure .. testing.. the milliamp output .. mA output trim .. mA output trim .. sensor simulation to test, tune, and troubleshoot the system .. up and restoring the Configuration .. the Configuration .. 83 Chapter 8 Operating the Transmitter .. delay .. mA output data .. process variables .. process variables.

5 The display .. ProLink II .. the Communicator .. and acknowledging status alarms .. status alarms .. the display .. ProLink II .. the Communicator .. the totalizers and inventories .. current totals for totalizers and inventories .. totalizers and inventories .. 92 Chapter 9 Measurement Performance .. validation and calibration.. validation and meter factors.. and recommendations .. meter validation.. density calibration .. for density calibration .. calibration procedures.. temperature calibration .. 101 Chapter 10 Troubleshooting .. to troubleshooting topics.. Motion customer service .. does not operate.. does not communicate .. or calibration failure.. power and mA fault action.

6 105ivMicro Motion Model 2200S conditions .. output problems .. I/O problems .. Sensor simulation mode .. Status alarms .. Checking process variables .. Diagnosing wiring problems .. the power supply wiring .. grounding.. the HART communication loop .. Checking the communication device.. Checking the output wiring and receiving device .. Checking slug flow .. Checking output saturation .. Checking the HART address and Loop Current Mode parameter .. Checking the flow measurement Configuration .. Checking the characterization.. Checking the calibration .. Checking the test points .. the test points .. gain problems .. pickoff voltage.

7 Checking sensor circuitry .. 117 Appendix A Default Values and Ranges .. frequently used defaults and ranges .. 123 Appendix B Flowmeter Installation Types and Components .. components .. diagrams.. 128 Appendix C Model 2200S Display and User Interface .. the components of the user interface .. and replacing the transmitter housing cover .. the display, the buttons, and the display menu system .. the display menu system .. floating-point values from the display menus .. and abbreviations .. 133 Appendix D Connecting with ProLink II Software .. upload/download .. from a PC to a Model 2200S transmitter .. II language .. 138 Configuration and Use ManualvContentsAppendix E Using the 375 Field Communicator.

8 Device description .. to a transmitter .. to HART clips .. to a multidrop network .. the Communicator with the Model 2200S .. safety messages and notes .. 141 Index .. 143viMicro Motion Model 2200S TransmittersConfiguration and Use Manual1 Before You BeginChapter 1 Before You chapter provides an orientation to the use of this Manual . This Manual describes the procedures required to start, configure, use, maintain, and troubleshoot the Model 2200S you do not know what transmitter you have, see Section for instructions on identifying the transmitter type from the model number on the transmitter s messages are provided throughout this Manual to protect personnel and equipment. Read each safety message carefully before proceeding to the next this manualThis Manual is organized into four sections, as described in Table 1-1.

9 Tab le 1 -1 Manual organizationSectionChaptersAudienceDescr iptionCommissioning2 Person responsible for process design and device configurationPerson responsible for device testing and commissioning Quick start tools for device commissioning3 through 7 Detailed information for all parameters that can be configuredProcedures for testing device operationProcedures for backing up and write-protecting configurationOperation8 Person responsible for operationProcedures for viewing process data and alarms, and managing totalizers and inventoriesMaintenance and troubleshooting9 and 10 Person responsible for periodic maintenance and troubleshootingInformation and procedures for flowmeter zero, meter proving, calibration, and information2 Micro Motion Model 2200S TransmittersBefore You your model numberModel 2200S transmitter options are encoded in the model number located on the transmitter tag.

10 The model number is a string of the following form:2200S*(H or K)**In this string: H = No adapter-barrier supplied with the transmitter K = Adapter-barrier supplied with the transmitterNote: See the product data sheet for information on the remaining characters in the model version informationTable 1-2 lists the version information that you may need and describes how to obtain the information. toolsTo configure and administer the Model 2200S transmitter, an administrative connection is required. You can use any of the following tools for the administrative connection: 375 Field Communicator with the following device descriptionMicro Motion 2200S Analog ProLink II software, and laterInformation on setting up the administrative connection is provided in Chapter : Some Configuration and administrative procedures can also be performed via the display menus.


Related search queries