Transcription of ControlLogix EtherNet/IP Network Devices User Manual
1 ControlLogix EtherNet/IP Network DevicesCatalog Numbers 1756-EN2F, 1756-EN2T, 1756-EN2TP, 1756-EN2 TPK, 1756-EN2 TPXT, 1756-EN2TR, 1756-EN2 TRK, 1756-EN2 TRXT, 1756-EN2 TXT, 1756-EN3TR, 1756-EN3 TRK, 1756-EN4TR, 1756-EN4 TRK, 1756-ENBT, 1756-EWEBUser ManualOriginal Instructions2 rockwell automation Publication 1756-UM004C-EN-P - June 2021 ControlLogix EtherNet/IP Network Devices User ManualImportant User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be no event will rockwell automation , Inc.
2 Be responsible or liable for indirect or consequential damages resulting from the use or application of this examples and diagrams in this Manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, rockwell automation , Inc. cannot assume responsibility or liability for actual use based on the examples and patent liability is assumed by rockwell automation , Inc. with respect to use of information, circuits, equipment, or software described in this of the contents of this Manual , in whole or in part, without written permission of rockwell automation , Inc., is this Manual , when necessary, we use notes to make you aware of safety may also be on or inside the equipment to provide specific : Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic : Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.
3 Attentions help you identify a hazard, avoid a hazard, and recognize the information that is critical for successful application and understanding of the HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). rockwell automation Publication 1756-UM004C-EN-P - June 20213 Table of ContentsPreface .. 5 About This Publication .. 5 Conventions .. 5 Download Firmware, AOP, EDS, and Other Files.
4 5 Summary of Changes.. 5 Additional Resources .. 6 Chapter 1 ControlLogix EtherNet/IP Network Device OverviewOverview .. 7 ControlLogix Network Device Features .. 7 EtherNet/IP Network Specifications.. 9 Simple Network Management Protocol .. 13 Enable SNMP .. 13 Disable SNMP .. 14 Electronic Keying .. 16 Protected Mode .. 17 Protected Mode in a Redundant Adapter Pair .. 18 How to Determine if the Module is in Explicit Protected Mode .. 19 Secure Digital Card .. 20 CIP Security .. 22 Parallel Redundancy Protocol .. 23 Device Level Ring (DLR) .. 23 Chapter 2 Connect to the EtherNet/IP NetworkSet the IP Address .. 25 Requirements .. 25 Set the IP Address with Rotary Switches.. 26 Mode Rotary Switch .. 27 Other Methods to Set the IP Address .. 27 Reset the Module IP Address to Factory Default Value .. 27 Redundant Adapter Considerations Setting the IP Address.
5 28 Chapter 3 Connect Redundant EtherNet/IP AdaptersRedundant Design Considerations .. 29 Redundant System Components .. 30 Redundant Switchovers .. 30 Switchover Considerations .. 30 Status Display Codes .. 31 Configure a 1756-EN4TR Redundant Adapter Pair .. 32 Redundant Architecture .. 39 Redundant Architecture Network Considerations .. 41 Redundant PRP Architecture with Redbox Switches .. 434 rockwell automation Publication 1756-UM004C-EN-P - June 2021 Appendix AControlLogix Network Device Status IndicatorsStatus Indicators.. 45 Single-Port Module Status Indicators.. 47 Dual-Port Module Status Indicators .. 49 Diagnostic Web Pages .. 50 Access the Diagnostic Web Pages .. 51 Index .. 53 rockwell automation Publication 1756-UM004C-EN-P - June 20215 PrefaceAbout This PublicationThis Manual describes how you can use ControlLogix EtherNet/IP communication modules with a Logix 5000 controller and communicate with various Devices on the EtherNet/IP this Manual if you program applications that use EtherNet/IP networks with these Logix 5000 controllers: CompactLogix controller ControlLogix controllerConventionsBe sure to understand these concepts and tools.
6 FactoryTalk Linx Logix Designer ControlFLASH Plus HMIs SNMP toolsDownload Firmware, AOP, EDS, and Other Files Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes from the Product Compatibility and Download Center at of ChangesThis Manual was revised to add or update the information that is listed in this EtherNet/IP Specifications10 Simple Network Management Protocol13 How to Determine if the Module is in Explicit Protected Mode19 Redundant PRP Architecture with Redbox Switches43 Diagnostic Web Pages506 rockwell automation Publication 1756-UM004C-EN-P - June 2021 Additional ResourcesThese documents contain additional information concerning related products from rockwell can view or download publications To order paper copies of technical documentation, contact your local Allen-Bradley distributor or rockwell automation sales EtherNet/IP Communication Modules Installation Instructions.
7 Publication 1756-IN050 Provides information on installing EtherNet/IP ControlLogix Communication Modules Specifications, publication 1756-TD003 Specifications for ControlLogix communication Redundancy User Manual , publication 1756-UM535 Provides information specific to redundancy Device Level Ring within a Converged Plantwide ethernet Architecture Design and Implementation Guide, publication ENET-TD015 Highlights the key IACS application requirements, technology, and supporting design considerations to help with the successful design and deployment of these specific use cases within the CPwE Design Considerations Reference Manual , publication ENET-RM002 Provides details about how to use EtherNet/IP communication modules with Logix 5000 controllers and communicate with other Devices on the EtherNet/IP Device Level Ring Application Technique, publication ENET-AT007 Describes DLR Network operation, topologies, configuration considerations, and diagnostic Media Planning and Installation ManualThis Manual is available from the Open DeviceNet Vendor Association (ODVA) at.
8 Details about how to install, configure, and maintain linear and Device Level Ring (DLR) networks by using rockwell automation EtherNet/IP Devices that are equipped with embedded switch Network Devices User Manual , publication ENET-UM006 Describes how to use EtherNet/IP communication modules in Logix 5000 control Parallel Redundancy Protocol Application Technique, publication ENET-AT006 Describes how you can configure a Parallel Redundancy Protocol (PRP) Network with a compatible device or Socket Interface Application Technique, publication ENET-AT002 Describes the socket interface that you can use to program MSG instructions to communicate between a Logix5000 controller via an EtherNet/IP module and ethernet Devices that do not support the EtherNet/IP application protocol, such as bar code scanners, RFID readers, or other standard ethernet automation Wiring and Grounding Guidelines, publication general guidelines for installing a rockwell automation industrial Certifications website, declarations of conformity, certificates, and other certification EtherNet/IP Networks Application Technique.
9 Publication ENET-AT003 Provides details about how to assign IP addresses to and how to troubleshoot EtherNet/IP networks and automation Publication 1756-UM004C-EN-P - June 20217 Chapter 1 ControlLogix EtherNet/IP Network Device OverviewOverviewEtherNet/IP networks are communication networks that offer a comprehensive suite of messages and services for many automation open Network standard uses commonly available ethernet communication products to support real-time I/O messaging, information exchange, and general Network Device FeaturesThe ControlLogix EtherNet/IP Network Devices : Facilitate high-speed data transfer between Logix 5000 controllers and remote I/O modules. Connect to multiple EtherNet/IP Network 1 shows how rockwell automation EtherNet/IP communication modules fit into a control Network Device Features7 EtherNet/IP Network Specifications9 Electronic Keying16 Protected Mode17 Protected Mode in a Redundant Adapter Pair18 Secure Digital Card20 CIP Security22 Parallel Redundancy Protocol23 Device Level Ring (DLR)
10 238 rockwell automation Publication 1756-UM004C-EN-P - June 2021 Chapter 1 ControlLogix EtherNet/IP Network Device OverviewFigure 1 - EtherNet/IP Communication Modules in a Control SystemSTATUSNETLINK 1 LINK 25094-AENTRE therNet/IP AdapterFLEX 5000TM I/OPRPDLRPOWERX100X10X1IP ADDRESSSTATUSPOWERDIGITAL 16 INPUT 24 VDC5094-IB1611TB3 FLEX 5000TM I/O0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 STATUSPOWERDIGITAL 16 OUTPUT 24 VDC5094-OB1612TB3 FLEX 5000TM I/O0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 STATUSPOWERRELAY 8 OUTPUT ISOLATED5094-OW8I22TB3 WFLEX 5000TM I/O0 1 2 3 4 5 6 7 Logix5575 Redundancy ModuleEtherNet/IPPRI COM OKControlNetEtherNet/IPControlNetOKFORCE SDRUNRUN REM PROG 1 2 LNK1 LNK2 OK10/100 BASE T LNK NET OKEtherNet/IP LNK NET OKSwitch1756-EN4TR1756 I/O Modules1794-AENT 1794 I/O ModulesWorkstationControlLogix 5580 Controller 1756 I/O Modules1769-L27 ERM1769 I/O Modules5069-AEN2TR 5069 I/O Modules5069-L340 ERM5069 I/O Modules1783-ETAPP anelView Terminal1783-ETAPW orkstationStratix 54005094-IB16 FLEX 5000 I/O1734-AENTR1734 I/O Modules1738-AENTR 1738 I/O ModulesPowerFlex DriveKinetix 6500 Servo DriveStar Topology1769-L18 ERM1734 I/O ModulesDLR Topology1756-EN4 TRControlLogix ControllerRockwell automation Publication 1756-UM004C-EN-P - June 20219 Chapter 1 ControlLogix EtherNet/IP Network Device OverviewEtherNet/IP Network SpecificationsTable 1 - EtherNet/IP Communication