Example: quiz answers

Current and Voltage Sensors - Eaton

Volume 8 Sensing SolutionsCA08100010E September and Voltage SensorsEVT Series VoltageWatch ECSJ Series CurrentWatch Current Switch EACR Series CurrentWatch Current Selection Guide .. Series VoltageWatch Voltage SensorsProduct Description ..V8-T7-5 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-8 Product Selection .. Series Compact CurrentWatch Current SwitchesProduct Description ..V8-T7-10 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-13 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-17 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-21 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-25 Product Selection .. Series CurrentWatch Current SensorsProduct Description ..V8-T7-28 Product Selection.

Volume 8—Sensing Solutions CA08100010E—September 2017 www.eaton.com V8-T7-1 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Current and Voltage Sensors EVT Series VoltageWatch ECSJ Series CurrentWatch Current Switch

Tags:

  Current, Eaton, Voltage, Sensor, Current and voltage sensors

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Current and Voltage Sensors - Eaton

1 Volume 8 Sensing SolutionsCA08100010E September and Voltage SensorsEVT Series VoltageWatch ECSJ Series CurrentWatch Current Switch EACR Series CurrentWatch Current Selection Guide .. Series VoltageWatch Voltage SensorsProduct Description ..V8-T7-5 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-8 Product Selection .. Series Compact CurrentWatch Current SwitchesProduct Description ..V8-T7-10 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-13 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-17 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-21 Product Selection .. Series CurrentWatch Current SwitchesProduct Description ..V8-T7-25 Product Selection .. Series CurrentWatch Current SensorsProduct Description ..V8-T7-28 Product Selection.

2 Series CurrentWatch Current SensorsProduct Description ..V8-T7-32 Product Selection .. Series CurrentWatch Current SensorsProduct Description ..V8-T7-35 Product Selection .. Series CurrentWatch Current SensorsProduct Description ..V8-T7-39 Product Selection .. Series CurrentWatch Current SensorsProduct Description ..V8-T7-44 Product Selection ..V8-T7-45 For Customer Service in the call 1-877-ETN CARE (386-2273),in Canada call Application Assistance in the and Canadacall otherwise noted, the products contained in this section should not be used for functional safety applications. These products were not designed or tested to IEC 60947-5-3 or recommended for functional safety. Volume 8 Sensing Solutions, CA08100010 ETab 7 Current and Voltage SensorsRevision dateSectionChange page(s)Description09/08 to TOC09/08 edit09/08 deleted09/08 updated09/08/2017 AllAllRevision date changed to September 2017 to match printed volumeRevision notesV8-T7-2 Volume 8 Sensing SolutionsCA08100010E September and Voltage SensorsIntroduc tionProduct Selection GuideEVT Series VoltageWatch Voltage Sensors ECS Series CurrentWatch AC Current Switches ECSC Series Compact CurrentWatch Current Switches ECSJ Series CurrentWatch AC Current Switches Note1 ECSJ Series: ECSJ424SC, ECSJ404SC and ECSJ405SC not listed.

3 Page V8-T7-5 OverviewEaton s VoltageWatch sensor is a high-performance, true RMS sensor for sensing Voltage in single- and three-phase installations. ApplicationsDetect below normal or brown out Voltage conditions; protect against possible motor overheatingIdentify phase-loss conditions by detecting Voltage reduction in one or more phases of a three-phase motorMonitor overvoltage conditions associated with regenerative Voltage to help in diagnosing/avoiding motor drive issuesDetect Voltage conditions that may cause stress in or damage to soft starter components (SCRs)Product FeaturesTrue RMS output allows for use in situations where power supplied is non-sinusoidalStandard 4 20 mA loop powered output industry standard output works easily and reliably with existing controllersInput/output isolation input and output circuitry is electrically isolated for improved safetyCompact DIN rail mount enclosure space-saving 35 mm wide enclosure mounts quickly for an attractive installationVo l t a ge R a n ge120, 240, 480 VApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-8 OverviewAC Current switches for detecting overcurrent proof of flow Current operated switches eliminate the need for multiple pipe or duct penetrations and are more reliable than electro-mechanical pressure or flow switchesConveyors detect jams and overloadsLighting circuits easier to install and more accurate than photocellsFans.

4 Pumps and heating elements faster response than temperature sensorsCritical motors Ancillary equipment Product FeaturesUniversal outputs NO or NC solid-state switch for control circuits up to 240 Vac/Vdc, compatible with most automation systemsSelf-powered cuts installation and operating costsEasily adjustable set point increases application flexibly and speeds start-upSolid- or split-core housings versions tailored for each type of installationLED indication provides quick visual indication of contact statusBuilt-in mounting feet simple, two-screw panel mount or attach with optional din-rail mounting kit accessory Current RangeFixed or adjustable set point, 1 150 AApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-10 OverviewAC/DC Current switches for detecting AC Current above A trip point. ApplicationsIndependent monitoring of essential elements monitor Current flow to lights, heating coils, motors and other vital components within a systemLocal disconnects double check a contactor s auxiliary contact, which can incorrectly indicate the absence of a loadControl panels indicates the presence or absence of Current flow through circuit breakers and other componentsProduct FeaturesOutputs NO or NC solid-state switch for control circuits up to 120 Vac/Vdc.

5 Compatible with most automation systemsSelf-powered cuts installation and operating costsCompact size great for applications with space constrictionsHigh sensitivity detects A without wrapping the conductor around the sensor several timesCurrent A tripApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-13 OverviewJumper selectable AC switches with solid-state proof of flow Current operated switches eliminate the need for multiple pipe or duct penetrations and are more reliable than electro-mechanical pressure or flow switchesConveyors detect jams and overloadsLighting circuits easier to install and more accurate than photocellsFans, pumps and heating elements faster response than temperature sensorsCritical motors Ancillary equipment Product FeaturesChoice of NO or NC solid-state outputs 1 A at 240 Vac A at 30 Vdc 15 A at 120 Vac 3 A at 120 Vac A at 30 Vdc, dual contactSelf-powered cuts installation and operating costsEasily adjustable set point speeds start-up and reduces inventorySolid- or split-core housings choose the appropriate version for your applicationLED indication provides quick visual indication of output contact statusBuilt-in mounting feet provide for a secure installationCurrent RangeAdjustable set point.

6 200 AApprovals 1UL ListedUL tested to Canadian safety standardsCERoHS CompliantVolume 8 Sensing SolutionsCA08100010E September and Voltage SensorsIntroductionECS7 Series CurrentWatch AC Current Switches ECSTD Series CurrentWatch AC Current Switches ECSD Series CurrentWatch DC Current Switches EAC Series CurrentWatch AC Current Sensors Page V8-T7-17 OverviewSelf-calibrating AC Current switch with solid-state use Current overload models to detect conveyor jams caused by scenarios such as side-by-sidesElectronic proof of flow more reliable than electro-mechanical pressure or flow switches, with no need for pipe or duct penetrationsPump protection provides overload (jams) and underload (suction loss) indicationProduct FeaturesSelf-powered and self-calibrating reduces installation costsStatus monitoring, overload and operating window options choose the operating style that matches your applicationUniversal output AC or DC compatibility with any automation systemCurrent RangeSelf-calibrating set point, 150 AApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-21 OverviewAC Current switches with time protection serves as an electronic proof-of-operation; detects Current draw changes in motors when they encounter problems such as pumps running dry or pending bearing failure.

7 Non-intrusive and less expensive to install than differential pressure flow Sensors or thermal switchesHigh inrush or temporary overload Current adjustable start-up/delay timer allows 0 15 second delay to eliminate nuisance trips from high inrush or short overload conditionsProduct FeaturesAdjustable start-up/delay timer field adjustable from 0 15 seconds to eliminate nuisance alarms due to start-up inrush or temporary overcurrent conditionsChoice of NO/NC AC or universal outputs contact ratings of A at 240 Vac or universal outputs of A at 240 Vac/Vdc (NO models) and A at 135 Vac/Vdc (NC models) for use with most standard motor control systemsImproved ease of installation and use self-powered, split-core models simplify installation, A AC rating eliminates need for time delay relay, and status LED provides visual indication of set point trip and contact actionCurrent RangeAdjustable set point, 200 AApprovalsUL ListedUL tested to Canadian safety standardsCERoHS Compliant(ECSTD401SC and ECSTD402SC not listed)Page V8-T7-25 OverviewDC switch with solid-state or mechanical relay proof of flow Current operated switches eliminate the need for multiple pipe or duct penetrations Welders Instant indication of equipment statusLarge drive motors provide monitoring for field loss protectionPower supplies detect and signal over- Current condition before equipment damageUPS monitors battery outputAncillary equipmentProduct FeaturesChoice of mechanical relay or solid-state outputs SPDT (Form C)

8 Relay, A at 240 Vac or 30 VdcSolid-state, NO, A at 240 Vac/VdcEasily adjustable set point speeds start-up and reduces inventoryCompact, one-piece design easily fits in crowded control panelsInput isolation safer than shunt/relay combinationsAdaptive hysteresis hysteresis is five percent of set point, allowing closer control than fixed-hysteresis switchesSolid-core housingsCurrent RangeVaries by modelApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-28 OverviewAC Current sensor with analog outputs and power supply equipment analog Current reading for remote monitoring and software alarmsData loggers self-powered sensor helps conserve data logger batteriesPanel meters simple connection displays power consumptionProduct FeaturesHighly accurate factory matched and calibrated single-piece sensor is more accurate than traditional two-piece, field-installed solutionsAverage responding average responding algorithm gives an RMS output on pure sine waves, perfect for constant speed (linear) loadsJumper selectable ranges the ability to change input ranges reduces inventory and eliminates zero and spanIsolation output is magnetically isolated from the input for safety and elimination of insertion loss ( Voltage drop) Current Range0 200 AApprovalsUL ListedUL tested to Canadian safety standardsCERoHS Compliant(EACP models not listed)

9 V8-T7-4 Volume 8 Sensing SolutionsCA08100010E September and Voltage SensorsIntroduc tionEACR Series CurrentWatch RMS Current Sensors EDC Series CurrentWatch DC Current Sensors EGF Series CurrentWatch Ground Fault Sensors EGFL Series CurrentWatch Ground Fault Sensors Page V8-T7-32 OverviewTrue RMS AC Current sensing with 4 20 mA controlled loads monitoring Vdc output indicates how the motor and attached load are operatingSCR controlled loads accurate measurement of phase angle fired or burst fired (time proportioned) SCRs, with faster Current measurement than temperature sensorsSwitching power supplies and electronic ballasts true RMS sensing is the most accurate way to measure power supply or ballast input powerProduct FeaturesTrue RMS output true RMS technology is accurate on distorted waveforms like VFD or SCR outputsJumper-selectable ranges reduces inventory and eliminates zero and spanIsolation output is magnetically isolated from the input for safety and elimination of insertion loss ( Voltage drop)

10 Current Range0 200 A true RMSA pprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-35 OverviewCurrent sensing for DC loads up to 300 A with analog banks monitors load Current , monitors charging Current and verifies operationTransportation measures traction power or auxiliary loadsElectric heating elements monitors heater loads with a faster response time than temperature sensorsProduct FeaturesJumper-selectable ranges reduces inventory and eliminates zero or span potsIsolation output is magnetically isolated from the input for safety, also eliminating insertion loss ( Voltage drop)Internal power regulation cuts installation costs and works well, even with unregulated powerSplit core design and built-in mounting brackets makes installation quick and easyCurrent Range0 400 AApprovalsUL ListedUL tested to Canadian safety standardsCERoHS CompliantPage V8-T7-39 OverviewGround fault Sensors with solid-state or mechanical relay protection (typically 5 mA) detects sensitive ground fault conditions, which could cause injury to people, and functions as a sensor and alarm trigger when applied as an input to an overall ground fault protection systemEquipment protection (typically 10 or 30 mA)


Related search queries