Example: biology

Cutler-Hammer Motor Control Assemblies I2-1 …

Cutler-Hammer Motor Control Assemblies I2-1. January 1999 Low-Voltage Motor Control Centers General Description General Description Introduction Cutler-Hammer currently produces two Motor Control center designs;. Freedom and Advantage . Each MCC type provides quality group Motor Control for a wide variety of applications. Freedom MCCs offer the best Motor Control for traditional electromechanical starter applica- tions. The Advantage Motor starter brings solid-state technology to the electromechanical Motor starter industry. Each MCC model utilizes the same rugged enclosure and plug-in cell design. Refer to Table V for feature high- lights of each MCC design.

January 1999 CAT.71.01. T.E Cutler-Hammer Motor Control Assemblies Low-Voltage Motor Control Centers

Tags:

  Center, Control, Motor, Assemblies, Hammer, Cutler, Motor control centers, Cutler hammer motor control assemblies i2, Cutler hammer motor control assemblies

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Cutler-Hammer Motor Control Assemblies I2-1 …

1 Cutler-Hammer Motor Control Assemblies I2-1. January 1999 Low-Voltage Motor Control Centers General Description General Description Introduction Cutler-Hammer currently produces two Motor Control center designs;. Freedom and Advantage . Each MCC type provides quality group Motor Control for a wide variety of applications. Freedom MCCs offer the best Motor Control for traditional electromechanical starter applica- tions. The Advantage Motor starter brings solid-state technology to the electromechanical Motor starter industry. Each MCC model utilizes the same rugged enclosure and plug-in cell design. Refer to Table V for feature high- lights of each MCC design.

2 Layout Guide . Space Requirements Table Combination Starters, Series C Motor Circuit Protectors or Molded Case Circuit Breakers ..A. Combination Starters, Fusible Switch ..B. AF91 Adjustable Frequency Controller ..C. SV9000 Adjustable Frequency Controller ..D. AF95 Adjustable Frequency Controller .. E. Incoming Line and Feeder I. Circuit Breakers .. F. Incoming Line and Feeder Fusible Switches .. G. Lighting Panelboards ..H. Automatic Transfer Switches .. I. Dry-Type Distribution 2100 Series Motor Control center Transformers .. J. Power Factor Correction Characteristics Page Characteristics Page Capacitors.

3 K Replacement Units .. I2-2 Unit Wrapper .. I2-9. Current Limiting Reactors .. L. UL Labeling .. I2-2 Terminal Blocks .. I2-9. TVSS (Clipper Power System) .. M. NEMA Wiring Classes .. I2-3 Unit Doors.. I2-10. DeviceNet Communications .. N. Structures .. I2-3 Additional Equipment .. I2-10. Earth Leakage Breakers .. O. Metering and Protection Wireways.. I2-4 Control and Load Equipment .. P Bus System .. I2-5 Terminations .. I2-11. Standard Structures and Starter Units .. I2-7 Incoming Terminations .. I2-11. Structure Options.. Q Feeder Tap Units .. I2-7 Solid-State Devices .. I2-12. Structure Modifications.

4 R Stab Assembly .. I2-8 Metering, IMPACC/PowerNet .. I2-13. Bus Modifications ..S Handle Mechanism.. I2-8 Additional Services .. I2-14. Main Lugs Only .. T Device Panel .. I2-9 Specifications .. I2-37. Control Power Transformer Layout Template.. I2-41. Data .. U. MCC Ratings and Highlights ..V. Overcurrent Device Selection Guide .. W. Starter Selection Guide ..X. I2-2. Motor Control Assemblies Cutler-Hammer Low-Voltage Motor Control Centers January 1999. General Description Features temperature and short circuit design MCC model UL Label test program as required by UL 845 Type of plug-in unit ensures a quality product that meets 65,000 AIC Ratings the latest safety codes.

5 Required features Series C Circuit Breakers Circuit breaker or fuse rating Replacement MCC Units 3200A Maximum Horizontal Bus Schematic reference, if any In addition to fully assembled, free- Labyrinth Barrier System for Bus standing Motor Control center line- Motor data Pull Apart Latching Terminal ups, replacement MCC plug-in units Standard Five Star, Series 2100, Blocks are available for: Freedom Series 2100 and Advan- Unit Grounding Clip Westinghouse 11-300, built tage plug-in units with current Cut- from 1950 ler- hammer components wired to Front Only or Front and Rear Unit standard schematics can be obtained Mounting Westinghouse Type W, built out of stock from one of seven from 1965 regional Service Centers.

6 All other Solid-State Motor Control Westinghouse FIVE STAR, built units are to be ordered from the MCC. Description from 1975 assembly plant in Fayetteville, NC. Motor Control Centers (MCC) pro- Westinghouse SERIES 2100, built vide the best method for grouping NEMA Classifications since 1986. Motor Control , associated Control Class I Control Centers and distribution equipment. The Westinghouse Advantage, built These are essentially a mechanical Freedom and Advantage 2100 Series since 1991 grouping of combination Motor Control Centers are specially Cutler-Hammer 9800, built Control , feeder tap and/or other units designed to operate machinery, from 1956 arranged in a convenient assembly.

7 Industrial processes and commercial They include connections from the Cutler-Hammer F10, built from building systems. common horizontal power bus to the 1972. units. They do not include interwir- The MCC enclosure consists of a Cutler-Hammer Freedom, built ing or interlocking between units or strong and rigid steel channel frame- since 1988 to remotely mounted devices, nor do work assembled into standardized Cutler-Hammer Freedom Series they include Control system engi- vertical sections and bolted together 2100, built since 1995 neering. Diagrams of the individual to form a complete shipping section units only are supplied.

8 Of up to 80-inch maximum, four A complete plug-in unit for adding to I structures each. Structures include an existing MCC includes the plug-in When master terminal blocks are horizontal and vertical bus, insula- unit, hinged door, isolating divider specified, a sketch showing general tion and isolation barriers, horizontal pan, and all necessary installation location of terminals is provided. and vertical isolated wiring troughs, hardware. Note: mounting hard- cable entrance areas and space ware for old Cutler-Hammer MCC is Class II Control Centers for inserting starter and Control sold separately. Since MCC UL 845 These are basically the same as equipment.

9 Standard was established in 1975, Class I, but designed to form a com- most standard replacement plug-in plete Control system. They include All Control units, removable or fixed the necessary electrical interlocking units will have UL labels. mounted, are assembled with cutler - and interwiring between units and hammer components with proven Ordering Information interlocking provisions to remotely safety, quality and reliability. All Replacement plug-in units should be mounted devices. A suitable diagram components are wired in accordance ordered by description indicating: illustrating operation of the Control with NEC and UL standards.

10 Specifi- associated with the Motor Control cally designed bus stabs, insertion Old GO Number/Factory Order center will be provided. guides, handle mechanisms and Number safety interlocks are added to form Further Information a standardized plug-in unit which meets the highest safety standards. 2100 Series MCC Freedom Advantage Both Freedom and Advantage 2100 Renewal Parts Data RPD 8991 RPD 8991. Series MCCs may be applied on elec- Renewal Parts Price List RPPL 8991A RPPL 8991A. trical systems up to 600V, 50 Price List or 60 hertz having available fault Instructions and Installation Manual IB 8926-1 IB 8922-1.


Related search queries