Danfoss Drives Fieldbus Solutions

Danfoss Drives Fieldbus Solutions Fast installation easy integration Dedicated Danfoss Fieldbus hardware and software Solutions save time and provide efficient control and monitoring. 20+. Fieldbus technologies supported by Danfoss AC Drives Freedom to communicate Real time information is becoming increasingly important in industrial automation and control systems as we progress further into Industry Immediate access to data increases transparency in production facilities, while making it possible to optimize system performance, collect and analyze system data and provide remote support around the clock from anywhere in the world. Regardless of your application or your preferred communication protocol, both VLT and VACON Drives have an extremely wide variety of communication protocols to select from.

Traditional wiring. No fieldbus. In this system configuration, connections between the drive and PLC require one wire for each input that needs to be controlled or monitored.

Tags:

  Wiring

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Danfoss Drives Fieldbus Solutions

1 Danfoss Drives Fieldbus Solutions Fast installation easy integration Dedicated Danfoss Fieldbus hardware and software Solutions save time and provide efficient control and monitoring. 20+. Fieldbus technologies supported by Danfoss AC Drives Freedom to communicate Real time information is becoming increasingly important in industrial automation and control systems as we progress further into Industry Immediate access to data increases transparency in production facilities, while making it possible to optimize system performance, collect and analyze system data and provide remote support around the clock from anywhere in the world. Regardless of your application or your preferred communication protocol, both VLT and VACON Drives have an extremely wide variety of communication protocols to select from.

2 In this way you can ensure that the AC drive integrates seamlessly into your chosen system providing you the freedom to communicate however you see fit. 5 5 5 5 5. Traditional wiring . No Fieldbus . Serial Fieldbus connectivity 2 Danfoss Drives Traditional wiring . Serial Fieldbus connectivity Fieldbus over Ethernet No Fieldbus . A classical Fieldbus system only Ethernet-based systems use the speed In this system configuration, uses twisted pair connections to and versatility of connectivity to connections between the drive and communicate over serial protocols. improve overall system control. While PLC require one wire for each input that Compared to systems wired without component costs are slightly higher needs to be controlled or monitored.

3 Fieldbus connections, serial Fieldbus than in serial systems, large gains are The advantage of such a system is that connectivity has a higher cost of made in ease of installation and a the individual components themselves components. Overall, Fieldbus reduction of connection errors. are relatively inexpensive. Solutions offer several advantages: fewer cable connection points, faster In Ethernet-based systems, the control This, however, comes at a price, as such commissioning and a reduced risk of hierarchy can be bypassed, sending systems are often expensive to install faults. messages directly to the components and extend. Each additional device or or through the PLC as needed.

4 Signal requires new wiring , can require The addition of other components in Additional Drives can be connected in additional PLC hardware, and always the system requires programming only ring topologies, in series over dual-port requires additional PLC programming the new inputs into the PLC, which is Solutions or directly with the network and verification. For owners this means both faster, safer and at significantly through external switches. higher capital costs and restricted lower cost than a hardwired system. flexibility. At the same time the risk of External access is routed through error is high as the number of I/O and a secure firewall, enabling wires increase. communication directly with the drive or with the web server built into some of the Fieldbus options.

5 Not only does this provide a high degree of flexibility during commissioning, it also provides advantages such as external monitoring and application support. Fieldbus over Ethernet Danfoss Drives 3. 4 Danfoss Drives Danfoss AC Drives support all leading industry fieldbuses Increase productivity User friendly and fast setup Factory fitted Fieldbus communication reduces Danfoss fieldbuses can be configured or plug-and-play capital costs in production plants. In via the drive's local control panel, which Delivered with the chosen addition to the initial savings achieved features a user friendly interface with communication protocol installed through the significant reduction in support for many user languages.

6 From the factory, Danfoss Drives wiring and control boxes, Fieldbus The drive and Fieldbus can also be are easy to integrate with PLC. networks are easier to maintain, configured using the software tools systems and motors regardless of while providing improved systems that support each drive family. manufacturer. performance. The time saving setup procedure Danfoss Fieldbus options can also is identical for VLT and VACON . be installed as a plug-and-play Fieldbus configuration files solution if required at a later stage for easy PLC integration if the production layout demands Integrating a drive into an existing Global Fieldbus experts a new communication platform. bus system can be time consuming Danfoss ' global sales and support and complicated.

7 To make this organization is trained in the market's process easy and more efficient, many PLC systems. With in-depth Danfoss Drives offers Fieldbus drivers knowledge about the challenges in and PLC examples, which can be modern production plants, they are downloaded for free from the Danfoss perfectly equipped to provide advice Drives website. After installation of and help so your Danfoss AC Drives these Fieldbus configuration files, the perform optimally. remaining bus parameters can be set directly in the drive. Danfoss Drives 5. 6 Danfoss Drives Fieldbus overview VLT Refrigeration Drive VLT AutomationDrive VLT Decentral Drive VACON 100 FLOW. VLT AQUA Drive VLT HVAC Drive VLT Midi Drive VACON 20 CP.

8 VACON 100 X. VACON 3000. VACON 20 X. VACON NXP. VACON 100. VACON 20. Fieldbus FC 301 FC 302 FC 202 FC 102 FC 103 FC 280 FCD 302. PROFINET o o o o o o o o o o o o o o EtherNet/IP o o o o o o o o o o o o o EtherCAT o o o o o o o o o o o BACnet/IP o n n n n Modbus TCP o o o o o o o n n n o n POWERLINK o o o o PROFIBUS DP o o o o o o o o o o o o o o o DeviceNet o o o o o o o o o o o o CANopen o o o o o o o o o o o BACnet MS/TP o o o n n n o n Modbus RTU n n n n n n n n n n n n n o n Metasys N2 o o o n n n o n LonWorks o o o o o o AK-LonWorks o ASi Bus n o o o o o o Interbus o PROFISAFE . VLT 3000 PROFIBUS Converter MCA 113 o VLT 5000 PROFIBUS Converter MCA 114 o VLT DeviceNet Converter MCA 194 o o = optional, n = integrated, = optional, requires additional option PROFINET EtherNet/IP EtherCAT.

9 PROFINET uniquely combines the highest Ethernet is the future standard for communica- The EtherCAT offers connectivity to EtherCAT . performance with the highest degree of tion at the factory floor. EtherNet/IP is based on based networks via the EtherCAT Protocol. openness. The option is designed so that many the newest technology available for industrial of the features from the PROFIBUS can be use and handles even the most demanding The option handles the EtherCAT line reused, minimizing user effort to migrate requirements. communication in full speed, and connection PROFINET and securing the investment in EtherNet/IP extends commercial off-the-shelf towards the drive with an interval down to 4.

10 A PLC program. Ethernet to the Common Industrial Protocol ms in both directions. This allows the option to (CIP ) the same upper-layer protocol and participate in networks ranging from low Same PPO types as PROFIBUS for easy object model found in DeviceNet. performance up to servo applications. migration to PROFINET. Support of MRP The option offers advanced features such as: EoE Ethernet over EtherCAT support Support of DP-V1 Diagnostic allows easy, Built-in high performance switch enabling HTTP (Hypertext Transfer Protocol) for fast and standardized handling of warning line-topology, and eliminating the need for diagnosis via built-in web server and fault information into the PLC, external switches CoE (CAN Over Ethernet) for access to drive improving bandwidth in the system DLR Ring parameters Implementation in accordance with Advanced switch and diagnosis functions SMTP (Simple Mail Transfer Protocol).