Data sheet 3SK1111-1AB30 - RS Components
Design of the fuse link for short circuit protection of the NC contacts of the relay outputs required Diazed or Neozed fuses, operating class gL/gG: 6 A or MCB type A: 2 A or MCB type B: 2 A or MCB type C: 1 A Cable length for total of all sensor circuits with Cu 1.5 mm² and 150 nF/km maximum 2 000 m Make time with automatic start typical 200 ms
Tags:
Protection, Fuse, 3sk1111, 1ab30, 3sk1111 1ab30
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
APC Smart-UPS X-Series 2000/2200/3000 VA Operation Manual
docs.rs-online.comSmart-UPS X 2000/2200/3000 VA 1 Overview About the UPS The APC® by Schneider Electric Smart-UPS® X is a high performance uninterruptible power supply (UPS). It provides protection for electronic equipment from utility power blackouts, brownouts, sags,
Power, Smart, Supply, Uninterruptible power supply, Uninterruptible, Smart ups
LOCTITE 243™
docs.rs-online.comTDS LOCTITE® 243™, August-2016 For Cleanup 1. Cured product can be removed with a combination of soaking in a LOCTITE® solvent and mechanical abrasion such as a wire brush Loctite Material SpecificationLMS LMS dated June-29, 2009.
Shelf Life for Loctite Products - RS Components
docs.rs-online.comThe shelf life period for Loctite® products is one year from date of shipment from Henkel facilities or as indicated by package labeling. For optimal storage, maintain product at a temperature between 8°C (46°F) to 21°C (70°F). Storage below 8°C (46°F) or greater than 28°C (82°F) can adversely affect product properties.
AC Industrial Electric Motors Data Sheet
docs.rs-online.comThe power factor usually being referred to as cos Ø. The power factor is usually between 0.7 and 0.9, however this may vary depending on the motor size and rating. If there are many motors in an installation they will consume a lot of reactive power and will therefore have a lower power factor. Power supply authorities sometimes require the
SIM868 Hardware Design V1.00-150516 - RS Components
docs.rs-online.comSIM868 is a quad-band GSM/GPRS module that works on frequencies GSM 850MHz, EGSM 900MHz, DCS 1800MHz and PCS 1900MHz. SIM868 features GPRS multi-slot class 12/class 10 (optional) and supports
APPLICATION MKS-L MKS-SC
docs.rs-online.comNote: (1) These tools are for prototype tooling or repair. (2) YC tool has two crimping sections (A and B). YRS tool has also two crimping sections by inverting upper dies. Be sure to check applicable wires before use. Since the dies are fixed, the crimping height cannot be adjusted. Therefore, some of the
Charger Instructions for Duracell High-Speed Chargers (ALL)
docs.rs-online.com5. The charger is capable of accepting 100-240 V AV 50/60 Hz and therefore, can be used overseas with a corresponding regional plug converter. 6. If battery is fully charged and then reinserted right away into the charger, the fault Red Blinking LED indicator may occur since the battery is already fully charged 7.
Programmable Logic Controllers Beginner´s Manual
docs.rs-online.comThe programmable logic controllers of the FX1S,FX1N,FX2N,FX2NC,FX3G,FX3GC,FX3GE, FX3S,FX3U and FX3UC series are only intended for the specific applications explicitly described in this manual. All parameters and settings specified in this manual must be observed. The products described have all been designed, manufactured, tested and docu-
PLATINUM RESISTANCE THERMOMETER (PRT)
docs.rs-online.comBuy this and more at rspro.com RS PRO Sensors - PRT Guide 3 COMPARISON OF SENSOR TYPES PLATINUM RESISTANCE THERMOMETER THERMOCOUPLE THERMISTOR Sensor Platinum-wire wound or flatfilm resistor Thermoelement, two dissimilar metals/alloys Ceramic (metal oxides) Accuracy (typical values) 0.1 to 1.0°C 0.5 to 5.0°C 0.1 to 1.5°C Long term …
Data sheet 6ES7131-6BH01-0BA0
docs.rs-online.comfor standard inputs — parameterizable Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length)
Related documents
International standards for Electrical Installation
www.bre.co.ukIEC 60146 Semiconductor convertors - General requirements and line commutated convertors ... General requirements IEC 60269-2 Low-voltage fuses - Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) ... Protection for safety - Protection against electric shock
TECHNICAL SPECIFICATIONS FOR ELECTRICAL
engineeringprojects.comDC:Part 2, fuses for use by authorized persons, Section 2, examples of standardized fuses. 13703(Part 2-Section 2):1993/IEC-269-2-1(1987) LV Fuses for voltages not exceeding 1000 V AC or 1500 V DC:Part 4, Supplementary requirements for fuse links for the protection of semiconductor devices {Superseding IS 9224 (Part 4):1980}
Low-Voltage Switchgear and Controlgear - Rockwell …
literature.rockwellautomation.comGeneral preliminary comments The present technical manual is intended as an aid in project design and the application of low-voltage switchgear and controlgear in switchgear assemblies and machine control.