1 Data sheet6ES7155-6AA01-0BN0 SIMATIC ET 200SP, PROFINET bundle IM, IM 155-6PN ST, max. 32I/O modules and 16 ET 200AL modules, single hot swap, bundleconsists of: Interface module (6ES7155-6AU01-0BN0), Servermodule (6ES7193-6PA00-0AA0), BusAdapter BA 2xRJ45 (6ES7193-6AR00-0AA0)General informationProduct type designationIM 155-6 PN STHW functional statusFS01 Firmware function I&M dataYes; I&M0 to I&M3 Module swapping during operation (hotswapping)Yes; Single hot swapping Isochronous modeNoEngineering with STEP 7 TIA Portal configurable/integrated as ofversionV14 STEP 7 configurable/integrated as of SP4 and higher PROFINET as of GSD version/GSD / -Configuration controlvia datasetYesSupply voltageRated value (DC)24 V6ES7155-6AA01-0BN0 Subject to change without noticePage 1/405/21/2020 Copyright Siemenspermissible range, lower limit (DC) Vpermissible range, upper limit (DC) VReverse polarity protectionYesShort-circuit protectionYesMains buffering Mains/voltage failure stored energy time10 msInput currentCurrent consumption (rated value)
2 450 mACurrent consumption, mAInrush current, AI A sPowerInfeed power to the backplane WPower lossPower loss, WAddress areaAddress space per module Address space per module, byte; per input / outputAddress space per station Address space per station, byte; Dependent on configurationHardware configurationRack Modules per rack, ; + 16 ET 200AL modulesSubmodules Number of submodules per station, of PROFINET interfaces1; 2 ports (switch)1. InterfaceInterface types Number of ports2 integrated switchYes RJ 45 (Ethernet)Yes; Pre-assembled BusAdapter BA 2x RJ45 BusAdapter (PROFINET)Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FCProtocols PROFINET IO DeviceYes Open IE communicationYes Media redundancyYes; PROFINET MRPI nterface typesRJ 45 (Ethernet) 6ES7155-6AA01-0BN0 Subject to change without noticePage 2/405/21/2020 Copyright Siemens Transmission procedurePROFINET with 100 Mbit/s full duplex (100 BASE-TX) 10 MbpsYes; for Ethernet services 100 MbpsYes; PROFINET with 100 Mbit/s full duplex (100 BASE-TX) AutonegotiationYes AutocrossingYesProtocolsPROFINET IO DeviceServices IRTYes.
3 With send cycles of between 250 s and 4 ms in incrementsof 125 s PROFI energyYes Prioritized startupYes Shared deviceYes Number of IO Controllers with shareddevice, mode PROFINET system redundancy (S2)NoMedia redundancy MRPYes MRPDNoOpen IE communication TCP/IPYes SNMPYes LLDPYesInterrupts/diagnostics/status informationStatus indicatorYesAlarmsYesDiagnostics functionYesDiagnostics indication LED RUN LEDYes; green LED ERROR LEDYes; red LED MAINT LEDYes; Yellow LED Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapterPotential separationbetween backplane bus and electronicsNobetween PROFINET and all other circuitsYes.
4 1 500 V ACbetween supply and all other circuitsNoPermissible potential differencebetween different circuitsSafety extra low voltage SELV6ES7155-6AA01-0BN0 Subject to change without noticePage 3/405/21/2020 Copyright SiemensIsolationIsolation tested with707 V DC (type test)Standards, approvals, certificatesNetwork loading class2 Security levelAccording to Security Level 1 Test Cases conditionsAmbient temperature during operation horizontal installation , C horizontal installation , C vertical installation , C vertical installation , CAltitude during operation relating to sea level installation altitude above sea level, 000 m; Restrictions for installation altitudes > 2 000 m, seemanualConnection methodET-Connection via BU/BA SendYes; + 16 ET 200AL modulesDimensionsWidth50 mmHeight117 mmDepth74 mmWeightsWeight, g; IM 155-6 PN BA with 2x RJ45 ports and server modulelast modified:05/13/20206ES7155-6AA01-0BN0 Subject to change without noticePage 4/405/21/2020 Copyright Siemens