Datasheet DIN rail Mount CKR48 Series Rating from 10 A to 30 A @ 530 VAC. Slim (width) package SCR output for heavy industrial loads LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output PRODUCT SELECTION. control Voltage 10 A 20 A 30 A. 4-32 VDC control CKRD4810 CKRD4820 CKRD4830. 110-280 VAC control CKRA4810 CKRA4820 CKRA4830. 90-140 VAC control CKRB4810 CKRB4820 CKRB4830. 18-36 VAC control CKRA4810E CKRA4820E CKRA4830E. AVAILABLE OPTIONS. control Voltage D: 4-32 VDC. B: 90-140 VAC Overvoltage Protection A: 110-280 VAC Blank: Not Included Series AxxxxE: 18-36 VAC P: Included CKR D 48 20 E P -10. Operating Rated Load Current Switching Type Voltage 10: 10 Amps Blank: Zero Voltage Turn-On 48: 48-530 VAC 20: 20 Amps -10: Instantaneous Turn-On 30: 30 Amps Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1). Description 10 A 20 A 30 A. Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 48-530.

PRODUCT SELECTION Control Voltage 10 A 20 A 30 A 4-32 VDC Control CKRD4810 CKRD4820 CKRD4830 110-280 VAC Control CKRA4810 CKRA4820 CKRA4830 90-140 VAC Control CKRB4810 CKRB4820 CKRB4830

Tags:

  Control, Mount, Rail, Din rail mount

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Datasheet DIN Rail Mount - Crydom

1 Datasheet DIN rail Mount CKR48 Series Rating from 10 A to 30 A @ 530 VAC. Slim (width) package SCR output for heavy industrial loads LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output PRODUCT SELECTION. control Voltage 10 A 20 A 30 A. 4-32 VDC control CKRD4810 CKRD4820 CKRD4830. 110-280 VAC control CKRA4810 CKRA4820 CKRA4830. 90-140 VAC control CKRB4810 CKRB4820 CKRB4830. 18-36 VAC control CKRA4810E CKRA4820E CKRA4830E. AVAILABLE OPTIONS. control Voltage D: 4-32 VDC. B: 90-140 VAC Overvoltage Protection A: 110-280 VAC Blank: Not Included Series AxxxxE: 18-36 VAC P: Included CKR D 48 20 E P -10. Operating Rated Load Current Switching Type Voltage 10: 10 Amps Blank: Zero Voltage Turn-On 48: 48-530 VAC 20: 20 Amps -10: Instantaneous Turn-On 30: 30 Amps Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1). Description 10 A 20 A 30 A. Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 48-530.

2 Transient Overvoltage [Vpk] 1200 1200 1200. Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10. Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ sec] (2) 500 500 500. Maximum Load Current [Arms] 10 20 30. Minimum Load Current [Arms] Maximum Surge Current ( ) [Apk] 120 250 1200. Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum I t for Fusing ( msec) [A sec] 60 260 6000. Minimum Power Factor (with Maximum Load) Do not forget to visit us at: Copyright 2016 Crydom Inc. Specifications subject to change without notice. Datasheet DIN rail Mount INPUT SPECIFICATIONS (1). Description CKRD48xx CKRA48xx CKRB48xx CKRA48xxE. control Voltage Range VDC 110-280 Vrms 90-140 Vrms 18-36 Vrms Minimum Turn-On Voltage VDC 110 Vrms 90 Vrms 18 Vrms Must Turn-Off Voltage VDC 10 Vrms 10 Vrms Vrms Typical Input Current (4) 8-12 mA 5 mA @ 240 Vrms 5 mA @ 120 Vrms 10 mA @ 24 Vrms Maximum Turn-On Time [msec] (3) 1/2 Cycle 10 10 10. Maximum Turn-Off Time [msec] 1/2 Cycle 40 40 40.

3 GENERAL SPECIFICATIONS. Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 V DC) 109 Ohms Maximum Capacitance, Input/Output 8 pF. Ambient Operating Temperature Range -40 C to 80 C. Ambient Storage Temperature Range -40 C to 125 C. Status Indicator Display Green LED. Weight (typical) 10 oz. (280g). Encapsulation Thermally Conductive Epoxy Terminals Box Clamp Type Maximum Wire Size AWG # 10 (3mm). Recommended Terminal Screw Torque Range in-lb ( Nm). Min. Side by Side Spacing inch (20mm). GENERAL NOTES. 1) All parameters at 25 C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 3) Turn-on time for DC control instantaneous turn-on versions is msec 4) Input circuitry for DC control version incorporates active current limiter. MECHANICAL SPECIFICATIONS. MOUNTING. HOLE/SLOT. ( ) DIA. +3/A1 4/A2. All dimensions are in inches (millimeters). IN P. S. U. TU. T ST A.

4 CKR SERIES. SOLID STATE ( ) ( ) ( ). CONTACTOR. OUTPUT. 1/L1 2/T1..5. ( )..890. ( ) ( ). ! Current Rating 20A @ 25 C. 30. 20. 10. Caution High Temperature 20 40 60 80. HEAT SINK: ( ) BLACK ANODIZED. ALUMINUM. Do not forget to visit us at: Copyright 2016 Crydom Inc. Specifications subject to change without notice. Datasheet DIN rail Mount EQUIVALENT CIRCUIT BLOCK DIAGRAM. AC control AC 4 1 AC. Current Limiter AC/DC Trigger Converter Circuit *. AC 3 2 AC. * With Option P suffix DC control -DC 4 1 AC. Trigger Circuit *. +DC 3 2 AC. Current Limiter THERMAL DERATE INFORMATION. CKRX4830. 30. OUTPUT CURRENT (Arms). 25. CKRX4820. 20. 15. CKRX4810. 10. 5. 0. 0 10 20 30 40 50 60 70 80. AMBIENT TEMPERATURE ( C). AGENCY APPROVALS. Agency Approvals Designed in accordance with the requirements of IEC 62314. E116950 LR81689 129156. Rev. 031116. Do not forget to visit us at: Copyright 2016 Crydom Inc. Specifications subject to change without notice. Datasheet DIN rail Mount DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO /.

5 HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI . ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA . SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O . EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL'ESPLOSIONE. OR ARC FLASH. Eteindre EXPLOSION.. Desconectar Spenga tutta Disconnect all todos los toutes les Stellen Sie l'alimentazione . power before suministros de sources jeglichen che fornisce Strom ab, der . installing or energia a este d' nergie de questa working with equipo antes cet appareil dieses Ger t apparecchiatura this equipment. de trabajar avant de versorgt, bevor prima di lavorare . con este equipo. travailler Sie an dem a questa . Verify all Ger t Arbeiten . dessus de cet apparecchiatura connections Verificar todas durchf hren appareil and replace all las conexiones Verificare tutti Vor dem covers before y colocar todas V rifier tous i collegamenti Drehen auf turning on las tapas antes connections, et e sostituire Energie alle power. de energizer remettre tous tutte le coperture Anschl sse el equipo.

6 Couverts en prima Failure to follow berpr fen olace avant de dell'accensione these und alle El mettre sous instructions will Abdeckungen L'omissione di incumplimiento result in death de estas De non-suivi de ersetzen. queste istruzioni or serious injury. instrucciones ces instructions Unterlassung provocher la puede provocar provoquera la dieser morte o la muerte o mort ou des Anweisungen lesioni serie lesiones serias. l sions s rieuses k nnen zum s rieuses. Tode oder zu schweren Verletzungen f hren. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / . RISK OF MATERIAL DAMAGE AND HOT RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCH DEN UND. ENCLOSURE SURCHAUFFE DU BOITIER GEH USEERHITZUNG. The product's side panels may be hot, allow Les panneaux lat raux du produit peuvent tre Die Seitenw nde k nnen hei sein. Lassen Sie the product to cool before touching. chauds. Laisser le produit refroidir avant de le das Produkt abk hlen, bevor Sie es ber hren.

7 Follow proper mounting instructions including toucher. Beachten Sie die Montageanweisungen, torque values. Respecter les consignes de montage, et F hren Sie keine Fl ssigkeiten oder Do not allow liquids or foreign objects to enter notamment les couples de serrage. Fremdk rper in das Produkt ein. this product. Ne pas laisser p n trer de liquide ni de corps trangers l'int rieur du produit. Le non-respect de cette directive peut entra ner, Die Nichtbeachtung dieser Anweisung kann Failure to follow these instructions can result in des l sions corporelles graves ou des serious injury, or equipment damage. K rperverletzung oder Materialsch den dommages mat riels. zur Folge haben. RIESGO DE DA OS MATERIALES Y DE . RISCHIO DI DANNI MATERIALI E D'INVOLUCRO. SOBRECALENTAMIENTO DE LA UNIDAD CALDO.. Los paneles laterales del producto pueden I pannelli laterali dell'apparecchio possono . estar calientes. Esperar que el producto se scottare; lasciar quindi raffreddare il prodotto.

8 Enfr e antes de tocarlo. prima di toccarlo. Respetar las instrucciones de montaje, y en . Seguire le istruzioni di montaggio corrette. particular los pares de apretado. Non far entrare liquidi o oggetti estranei in questo No dejar que penetren l quidos o cuerpos apparecchio. extra os en el producto. La mancata osservanza di questa precauzione pu . Si no se respetan estas precauciones pueden causare gravi rischi per l'incolumit personale o producirse graves lesiones, da os materiales. danni alle apparecchiature.. Do not forget to visit us at: Copyright 2016 Crydom Inc. Specifications subject to change without notice. Datasheet DIN rail Mount ANNEX - ENVIROMENTAL INFORMATION. The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 2006, Marking for control of Pollution Caused by Electronic Information Products. Part Toxic or hazardous Substance and Elements Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium biphenyls diphenyl ethers (Cr (VI)) (PBB) (PBDE).

9 Semiconductor die Solder - . SJ/T11364 - 2006, .. (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE).. 50. Do not forget to visit us at: Copyright 2016 Crydom Inc. Specifications subject to change without notice.