Transcription of DataSheet DIN Rail Mount - Crydom
1 DataSheetDIN rail MountSeriesOne DR Series Ratings of 6 & 12 Amps Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC Fits standard 35mm din rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output UL and cUL Listed, HP Rated CE & RoHS Compliant UL 508 Endurance Rating for Enhanced Reliability UL Class I and II, Division 2, for Hazardous LocationsPRODUCT SELECTIONC ontrol Voltage 280, 6 A 280V, 12 A 600V, 6 A 600V, 12 A 60V, 6 A 60V, 12 A 100V, 6 A 100V, 12 A4-32 VDCDR24D06 DR10D1290-140 VACDR24B06200-280 VACDR24A06 AVAILABLE OPTIONSOUTPUT SPECIFICATIONS AC Output (2)DescriptionDR24x06DR24x12DR48x06DR48X 12 Operating Voltage Range (47-63Hz) [Vrms]24-28024-28048-60048-600 Transient Overvoltage [Vpk]60060012001200 Maximum Load Current, resistive [Arms] (3) Load Current [mArms]500500500500 Maximum Surge Current (50/60Hz, 1 cycle) [Apk] On-State Voltage Drop @ Rated Current [Vrms] 285/300715/750285/300715/750400/3752560/ 2330410/3752560/2330 Maximum I t for Fusing (50/60 Hz, 1/2 cycle) [A sec]1/2 (.)
2 37)1 (.75)1/2 (.37)1 (.75)1 (.75)2 ( )1 ( )2 ( )18-36 VACDR24D12DR24B12DR24A12DR48D06DR48B12DR 48E12DR48A12DR48D12DR06D06DR06D12DR10D06 DR24E06DR24E12 ACOutputOnlySeriesOperating Voltage06: 1-60 VDC10: 1-100 VDC24: 24-280 VAC48: 48-600 VACR ated Load Current06: 6 Amps12: 12 AmpsControl VoltageD: 4-32 VDCA: 200-265 VACB: 90-140 VACE: 18-36 VAC (1)1206 DDRXA gency ApprovalsX: ATEX II 3G Ex nA IIC T4 Gc approvedSwitching TypeBlank: Zero Voltage Turn-On (AC Output Only)R: Instantaneous Turn-On (AC Output, D suffix Only)RRequired for valid part numberFor options only and not required for valid part numberMaximum Off-State Leakage Current @ Rated Voltage [mArms]Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ sec] (4) HP Rating UL 508/IEC60947 [HP (KW)] @ 240 VMinimum Power Factor (at Maximum Load)Min/Max stranded wireHP Rating UL 508/IEC60947 [HP (KW)] @ 380 VHP Rating UL 508/IEC60947 [HP (KW)] @ 480 VMin/Max solid wireWeight (Typical) N/A2 ( )3 ( )3 ( ) AWG22/14 AWG22/14 AWG22/14 AWG22/14 AWG22/14 AWG22/14 AWG22/14 oz.
3 (50g) oz. (50g) oz. (90g) oz. (90g)Do not forget to visit us at: 2017 Crydom Inc. Specifications subject to change without rail MountDo not forget to visit us at: 2017 Crydom Inc. Specifications subject to change without SPECIFICATIONS(2)DRxxExxDRxxBxxDRxxDxxDe scriptionControl Voltage Range (5) 4-32 VDC200-265 Vrms18-36 Vrms (1)Min imum Tur n- On Vol VDC200 Vrms18 VrmsMust Turn-Off VDC40 Vrms4 VrmsMinimum Input Current for [mA] (6) Input Current for [mA] (6) Cycle20 msec20 msecMaximum Turn-on Time [msec] (7) (8)1/2 Cycle30 msec30 msecMaximum Turn-off Time [msec] (9)22/16 AWG22/16 AWG22/16 AWGGENERAL SPECIFICATIONS(2)DescriptionParametersDi electric Strength, Input/Output/Base (50/60Hz)4000 Vrms (10) Minimum Insulation Resistance (@ 500 VDC)Maximum Capacitance, Input/Output10 pFAmbi ent Operating Temperature Range-30 to 80 CAmbi ent Storage Temperature Range-30 to 100 CRecommended Ter minal Scre w Torque Range 109 OhmOUTPUT SPECIFICATIONS DC Output (2)DescriptionDR06D06DR10D06DR06D12DR10D 12 Operating Voltage [VDC]1-601-1001-601-100 Maximum Load Current [Adc] (3)
4 661212 Minimum Load Current [mAdc] Off-State Leakage Current @ Rated Voltage [mA]Maximum On-State Voltage Drop @ Rated Current [Vpk]6060On-State resistance at rated current [Ohms] stranded wire 22/14 AWG22/14 AWG22/14 AWG22/14 oz. (55g) oz. (50g)Min/Max solid wireWeight (typical)Maximum Surge Current (10ms) [Apk] AWG22/14 oz (90g) oz.(90g)22/14 AWGMin/Max stranded/solid wireDRxxAxx90-140 Vrms90 Vrms10 Vrms3520 msec30 msec22/16 AWGGENERAL NOTES (2) All parameters at 25 C unless otherwise specified. (1) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. (3) See Derating curves (4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph (5) DC control includes reverse polarity protection.(6) Input circuitry incorporates active current limiter.(7) Turn-on time for DC control random turn-on versions is msec.(8) Turn-on time for DC output 600 sec.(9) Turn-off time for DC output 300 sec.
5 (10) 2500 Vrms for DC A, Resistive or Slightly Inductive Load Ratings: 12 A @40 C ambient for DR24x12, 12 A @ 40 C ambient for DR48x12LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40 C ambient for DR24x06, 6 A @ 40 C ambient for DR48x06LC B, Motor Loads Ratings: @ 240 VAC for DR24x06 and @ 480 VAC DR48x12LC B, Motor Loads Ratings: @ 240 VAC for DR24x06 and @ 480 VAC DR48x12 Standards of Compliance IEC 62314 Shock and Vibration (Applies to all part numbers)Vibration Resistence according to IEC 60068-2-6: and Amplitude over 10-55 HzShock Resistance according to IEC 60068-2-27: 15g/11msEMC (Applies to all part numbers)IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locationsThis equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a toolsuitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations onlyWARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrationsWARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division in-lb ( )DataSheetDIN rail MountDo not forget to visit us at: 2017 Crydom Inc.
6 Specifications subject to change without SPECIFICATIONS(2)EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS Installed single unit, distance to adjacent components 11 mm for DRxxx06 & 18mm for DRxxx12 DataSheetDIN rail MountDo not forget to visit us at: 2017 Crydom Inc. Specifications subject to change without notice. Rev 052516654321100203040506070800 Ambient Temperature ( C)Load Current (Amps)DRxxx0612108642100203040506070800 Ambient Temperature ( C)Load Current (Amps)DRxxx12 Installed single unit, distance to adjacent components 11 mm for DRxxx06 & 18mm for DRxxx12 Multiple units, no minimum spacing between componentsAGENCY APPROVALSTHERMAL DERATE INFORMATIONE116949 IND. CONT. rail MountDo not forget to visit us at: 2017 Crydom Inc. Specifications subject to change without rail MountDo not forget to visit us at: 2017 Crydom Inc.
7 Specifications subject to change without / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSIO N, OR ARC FLASH. Di sconnect all power b efore insta lling or working with th is equipment. Verify all connecti ons and r eplace a ll covers b efore tu rning o n t o f ollow these in structio ns will result in d eath or s erio us inju ry. RIESGO DE DESCARGA ELECTRICA O EXPLOSIO N. Desconecta r to dos los suministr os d e energia a e ste equipo antes de tr abajar con e ste equipo. Verificar todas las conexiones y colocar todas las tapas antes de energizer el in cumplimie nto de e stas in struccio nes puede p rovocar la muerte o le sio nes s eria DE DESCHARGE ELECTRIQUE OU EXPLOSION Ete indre to ute s les sources d' nergie de cet a ppareil avant de tr availler dessus d e c et appareil V rifier tousconnections, etremettre tous couverts enolace avant demettre sousDe n on-suiv i de ces instructio ns provoquera la mort o u d es l sio ns s rieuses s EIN ES ELEKTRISCHEN SCHLAGES ODER EINER EXPLOSIO N.
8 Ste llen Sie jeglichen Str om a b, d er dieses G er t versorgt, bevor S ie an dem Ger t Arbeiten durchf hren Vor d em Dr ehen auf Energie alle Anschl sse berpr fen und alle Abdeckungen ssung die ser Anweisungen k nnen z um Tode o der z u schwerenVerle tzungen f DI SCOSSA ELETTRICA O DELL E SPLOSIONE. Spenga tu tt a l'alimenta zioneche f ornisce questa apparecchiaturaprima d i lavorarea questa apparecchiatura Verificare t utti i c ollegamenti e s osti tu ire tu tte le coperture prima dell accensioneL'omis sio ne d i queste istruzioni provocher l a morte ole sio ni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE The product's side panels may be hot, allow the product to cool before touching. Follow proper mounting instructions including torque values. Do not allow liquids or foreign objects to enter this to follow these instructions can result in serious injury, or equipment DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER Les panneaux lat raux du produit peuvent tre chauds.
9 Laisser le produit refroidir avant de le toucher. Respecter les consignes de montage, et notamment les couples de serrage. Ne pas laisser p n trer de liquide ni de corps trangers l'int rieur du non-respect de cette directive peut entra ner,des l sions corporelles graves ou des dommages mat Nichtbeachtung dieser Anweisung kannK rperverletzung oder Materialsch den zur Folge VON MATERIALSCH DEN UND GEH USEERHITZUNG Die Seitenw nde k nnen hei sein. Lassen Sie das Produkt abk hlen, bevor Sie es ber hren. Beachten Sie die Montageanweisungen, F hren Sie keine Fl ssigkeiten oder Fremdk rper in das Produkt no se respetan estas precauciones pueden producirse graves lesiones, da os DE DA OS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfr e antes de tocarlo. Respetar las instrucciones de montaje, y en particular los pares de apretado. No dejar que penetren l quidos o cuerpos extra os en el mancata osservanza di questa precauzione pu causare gravi rischi per l'incolumit personale o danni alle DI DANNI MATERIALI E D'INVOLUCRO CALDO I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
10 Seguire le istruzioni di montaggio corrette. Non far entrare liquidi o oggetti estranei in questo apparecchio. DataSheetDIN rail MountDo not forget to visit us at: 2017 Crydom Inc. Specifications subject to change without - ENVIROMENTAL INFORMATIONThe environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People s Republic of China Electronic Industry Standard SJ/T11364 2006, Marking for Control of Pollution Caused by Electronic Information or hazardous Substance and Elements LeadMercuryCadmiumHexavalent PolybrominatedPolybrominated(Pb)(Hg)(Cd) Chromium(Cr (VI)) biphenyls(PBB)diphenyl ethers (PBDE)Semiconductor dieSolder - SJ/T11364 - 2006, (Pb)(Hg)(Cd)(Cr (VI)) (PBB)(PBDE) 50
