Transcription of Dell EMC Data Domain DD3300 - Dell Technologies
1 dell EMC data Domain DD3300 Version Overview and Installation Guide302-004-565 REV 04 Copyright 2018- dell Inc. or its subsidiaries. All rights December 2018 dell believes the information in this publication is accurate as of its publication date. The information is subject to change without INFORMATION IN THIS PUBLICATION IS PROVIDED AS-IS. dell MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KINDWITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY dell SOFTWARE DESCRIBEDIN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE Technologies , dell , EMC, dell EMC and other trademarks are trademarks of dell Inc.
2 Or its subsidiaries. Other trademarks may be the propertyof their respective owners. Published in the EMCH opkinton, Massachusetts 01748-91031-508-435-1000 In North America Domain DD3300 Hardware Overview and Installation Guide57 Revision history9 Planning and Site Preparation11 Tools and supplies 13 data Domain DD3300 Hardware Overview15DD3300 system system 17DD3300 storage control 19 Right control 21 Front 23 Service 23 Rear 24 Product serial number tag (PSNT).. 26 Rear 26 NIC 27 Power supply the System in the Rack31 Identifying the rail kit the 32 Secure the rail assemblies to the the system in the 34 Install the front Cables and Power on39 Connect data 40 Connect power cables and power System for Use43 Enable administrative serial over LAN (SOL).
3 45 Configure 46 Run the configuration the 48 Configuring additional system 52 Configuring the system with the DD System Manager GUI interfaceconfiguration 53 FiguresTablesChapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 CONTENTSData Domain DD3300 Hardware Overview and Installation Guide3 License 54 File 59DD Boost 60 CIFS 61 NFS VTL 62 Using the 63 Using the CLI to configure storage for DD Cloud 64 Using the CLI to configure storage for the SSD Cache iDRAC to power the system on and off 67 CONTENTS4 data Domain DD3300 Hardware Overview and Installation GuideFront control 20 Right control 22 Disk 23 Service 24 Rear 24 PSNT 26 Disk 27 NIC 27 Power supply 28 Sliding rail assembly - 2U 32 Installing the rear end of the 33 Installing the front end of the 34 Pull the inner rails out of the 35 Install the system in the 35 Slide the system into the the front 37iDRAC Settings > 47iDRAC Settings > User 47iDRAC power Domain DD3300 Hardware Overview and Installation Guide5 FIGURES6 data Domain DD3300 Hardware Overview and Installation GuideDocument revision 9DD3300 system system 17 System operating storage 18 Front disk slot 19 Rear disk slot 25 Network daughter card port 25 Optional 10 GbE module port 26 Optional 16 Gbps FC module
4 Port daughter card port 40 Optional 10 GbE module port 41 Optional 16 Gbps FC module port 41 Communications 44 License Configuration page page 54 Interfaces page 55 DNS page 57 Active Tier 57 Addable 57 Cloud Tier 58 Addable 58 Cloud Tier 58 Administrator page page 59 Storage Unit page 60 Authentication page page 61 Export page 62 Library page 62 Access Group page 6312345678910111213141516171819202122232 42526272829303132 TABLESData Domain DD3300 Hardware Overview and Installation Guide7 TABLES8 data Domain DD3300 Hardware Overview and Installation GuideRevision historyTable 1 Document revision historyRevisionDateDocument partnumber/RevisionNumberSoftware versionDescription04 December 2018302-004-565, Rev.
5 For:l8 TB configurationl4 x 10 GbE RJ-45network daughtercardlOptional FC cardfor VTLlPort failoverlSerial over LANthrough iDRAC03 July 2018302-004-565, Rev. for:lStorage overheadenhancementslSSD Cache TiersupportlProduct serialnumber tagchanges02 February 2018302-004-565, Rev. 2018302-004-565, Rev. history 9 Revision history10 data Domain DD3300 Hardware Overview and Installation GuideCHAPTER 1 Planning and Site PreparationThis chapter contains the following information:lTools and supplies 12lSafety and Site Preparation 11 Tools and supplies neededThe following tools and supplies are required when working with data wrist strap and conductive foam padlScrewdrivers:nPhillips #2 with a 12 in.
6 Or longer blade and magnetic tipnPhillips #2 (standard-length blade) with magnetic tiplFlashlight (articulated or free-standing for single-person installations)lRoll of 5/8 inch Velcro cable tie material (3M Scotchmate SJ-3401 or similar)lCable to connect a service laptop to the data Domain system:nNull modem cable (full size DB-9 female to female), plus sparenUSB-to-DB-9 serial (male connector) converter cable if the laptop does nothave a serial port, plus sparelPower adapter, C13 to NEMA 5 15 (if based in North America), or a power cordfor your laptop power adapter with a C13 plug, so that you can power your laptopfrom a rack PDUlOne or two power cables for the data Domain system, depending on the numberof power supplies installed in the systemlData cables to connect the data Domain system to the customer network:nOne to four Cat 5e or Cat 6 copper Ethernet cablesnOne to two qualified 10 Gb Ethernet cables.
7 Fibre cables with a 10 Gb optical SFP Direct-attached copper cablesnOne to four qualified Fibre Channel cables for VTL following additional tools and supplies may be helpful when working with DataDomain :nPhillips #1nFlat head 3/16 head 1/4 T8nTorx T10nTorx T30lNeedle nose plierslDiagonal wire cutters (for cutting tie wraps)l2 GB or greater USB flash memory drivelTie wraps (4 in. and 8 in.)lLabelsPlanning and Site Preparation12 data Domain DD3300 Hardware Overview and Installation GuidelPenSafety overviewCAUTIONlIf the system is used in a manner not specified by the manufacturer, theprotection provided by the equipment may be RJ45 sockets on the motherboard, PCI cards, or I/O modules are forEthernet connection only and must not be connected to atelecommunications this list of important safety plug-in modules and blank plates are part of the fire enclosure and must beremoved only when a replacement can be added immediately.
8 The system mustnot be run without all parts in DD3300 system must be operated only from a power supply input voltage rangeof 100 240 VAC and 50 60 system is intended to operate with all installed power supplies working a suitable power source with electrical overload safe electrical earth connection must be provided to each power cord. Checkthe grounding of the power sources before applying plug on each power supply cord is used as the main device to disconnectpower from the system. Ensure that the socket outlets are located near theequipment and are easily unplug the unit if you think it is damaged in any way and beforemoving the system. A DD3300 system includes one or two power supplies.
9 Tocompletely remove system power, you must disconnect all power power connections must always be disconnected prior to removal orreplacement of a power supply module from any of the components in the faulty power supply module should be replaced within 24 not lift system components by yourself. A DD3300 system weighs up to ( kg).CAUTIONData Domain systems are heavy. Use at least two people or a mechanical liftto move any comply with applicable safety, emission, and thermal requirements, coversmust not be removed and all bays must be fitted with plug-in ESD protection, data Domain recommends that you wear a suitable antistaticwrist or ankle strap. Observe all conventional ESD precautions when handlingplug-in modules and and Site PreparationSafety overview 13 Planning and Site Preparation14 data Domain DD3300 Hardware Overview and Installation GuideCHAPTER 2 data Domain DD3300 Hardware OverviewThis chapter contains the following information.
10 LDD3300 system 16lDD3300 system 17lDD3300 storage 18lFront 19lRear 24 data Domain DD3300 Hardware Overview 15DD3300 system featuresTable 2 DD3300 system featuresFeature4 TB configuration8 TB configuration16 TB configuration32 TB configurationRackHeight2U, supported in four-post racks onlyPower1 or 2 hot-swappable power unitsFans6 hot swappable fans, installed in two fan assemblies (3 fans per fan assembly)RackmountingRack mount kit included with each system. Adjustable between 24 - 36 in. ( cm).Processor1 x 8-core Intel 4110 series, hyperthreadedVoltage100 240 V~. Frequency: 50 Hz to 60 " drives(front)4 x 4 TB HDD10 x 4 TB HDD10 x 4 TB HDD12 x 4 TB " drives(middle)N/AN/AN/A4 x 4 TB " drives(rear)N/A1 x 480 GB SSD for NVRAMaNIC4 x 1 GbE or 4 x 10 GbE (always present)b + 2 x 10 GbE (optional)FC (DDVTL only)4 x 16 Gbps (optional)Memory16 GB or 24 GBc48 GB48 GB or 56 GBd64 SSD is for use as an NVRAM device, and for SSD Cache Tier storage only.