DESIGNER REFRIGERATION INSTALLATION GUIDE
application. WATER SUPPLY LOCATION A 18" Model 3" (76) 24" Model 51/2" (140) 30" Model 6" (152) 36" Model 9" (229) 3" (76) 6" (152) RIGHT SIDE OF OPENING AREA EXTENDS 1/2" (13) FORWARD ON FLOOR A Water supply location SITE PREPARATION PLUMBING REQUIREMENTS Water Supply Line 1/4" OD copper, braided stainless steel, or PEX tubing …
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
INSTALLATIONGUIDE - subzero-wolf.com
www.subzero-wolf.comImportant Note To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide:
DUAL FUEL RANGE USE AND CARE GUIDE - Sub-Zero
www.subzero-wolf.comdo, please take some time to read this use & care guide. Whether you are an occasional cook or an expert chef, it will be to your benefit to familiarize yourself with the safety practices, features, operation and care recommendations of your Wolf dual fuel range.
GAS RANGE INSTALLATION GUIDE - subzero …
www.subzero-wolf.com4 | Wolf Customer Care 800.222.7820 Electrical Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the wall or floor and
WOLF VENTILATION GUIDE - subzero-wolf.com
www.subzero-wolf.comwolfappliance.com | 3 SELECTING A VENTILATION SYSTEM Selecting a Ventilation System When selecting a ventilation system, start by choosing the proper Wolf ventilation product, determined by the type of
Induction and Electric Cooktops Installation Guide
www.subzero-wolf.com4 | Wolf Customer Care 800.222.7820 Installation Requirements A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. Clearance is required for the conduit located at the right rear of induction and electric cooktops.
Guide, Installation, Electric, Induction, Cooktop, Induction and electric cooktops installation guide, Induction and electric cooktops
BUILT-IN REFRIGERATION USE AND CARE GUIDE
www.subzero-wolf.comBUILT-IN REFRIGERATION Customer Care The model and serial number are printed on the enclosed product registration card. Both numbers are also listed on
CONVECTION STEAM OVEN INSTALLATION GUIDE
www.subzero-wolf.com4 | Wolf Customer Care 800.222.7820 Electrical Installation must comply with all applicable electrical codes. Locate the electrical supply as shown in the illustrations on the following pages.
SEALED BURNER RANGETOP INSTALLATION GUIDE
www.subzero-wolf.comSEALED BURNER RANGETOP Contents 3 Specifications 6 Installation 7 Troubleshooting Features and specifications are subject …
BUILT-IN REFRIGERATION INSTALLATION GUIDE
www.subzero-wolf.com4 | Sub-Zero Customer Care 800.222.7820 SITE PREPARATION Opening Dimensions STANDARD INSTALLATION 3/4" (19) TYPICAL FRAMED CABINETRY W FILLER 31/2" (89) FINISHED RETURN FRAMELESS ...
Drawer Microwave Ovens Installation Guide
www.subzero-wolf.com4 | Wolf Customer Care 800.222.7820 Electrical Installation must comply with all applicable electrical codes. Locate the electrical supply as shown in the illustrations on
Related documents
Design Guide - Sub-Zero
www.subzero-wolf.comfor this application. Installation must comply with all applicable plumbing codes. PLUMBING REQUIREMENTS Water Supply 1/4" OD copper, braided stainless steel, or PEX tubing Pressure 35–120 psi (2.4–8.3 bar) Excess Line for Connection 36" (914) Electrical Requirements The electrical supply should be located within the shaded
Guide, Applications, Design, Zero, Plumbing, Design guide, Sub zero
DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL …
www.bpfpipesgroup.comThe Plumbing Engineering Services Design Guide, CIPHE. Safe water in healthcare premises (HTM 04-01). Always refer to the latest editions of these documents. MODULAR DESIGN Many manufacturers supply manifolds for use in heating systems. These provide an opportunity for modular system design.
Guide, Design, Supply, Water, Central, Cold, Plumbing, Design guide, Cold water supply and central
ROUGH-IN INSPECTION CHECKLIST
www.biupa.combey ond the m anufacturer s installation guide. Truss m em bers shall not be altered in any way without the approval of a design professional. Truss design drawings shall be provided at tim e of inspection. Use ‚hurricane clips€and room tie-downs as specified per m anufacturer or as required per Table R802.11. (R5 02.8.2, R5 02.11, R802.10.1)
Chemical Resistance Guide - Gilson Eng
www.gilsoneng.compressure and 82°C (180°F) in drainage. With a design stress of 2,000 psi, PVC has the highest long-term hydrostatic strength 22.7°C (73°F) of any other major thermoplastic material used for piping. PVC piping is joined by solvent cementing, thread-ing, flanging, grooving, gasketed joints, or …
Guide, Design, Resistance, Chemical, Chemical resistance guide
Chemical Resistance Guide - Gilson Eng
www.gilsoneng.compressure and 82°C (180°F) in drainage. With a design stress of 2,000 psi, PVC has the highest long-term hydrostatic strength 22.7°C (73°F) of any other major thermoplastic material used for piping. PVC piping is joined by solvent cementing, thread-ing, flanging, grooving, gasketed joints, or mechanical joints. CPVC
Guide, Design, Resistance, Chemical, Chemical resistance guide
Design & Installation Manual - Radiant Company
www.radiantcompany.comThe 7/8” Durapoly XL PEX is a large diameter tubing with the same wall thickness as the commonly used 1/2” PEX. It’s main advantage over 1/2” PEX lies in the fact that it holds more fluid, and consequently, more heat. It has a slightly lower temperature and pressure rating than 1/2” PEX, but it can be spaced as far apart as 16”
Manual, Design, Installation, Design amp installation manual