DisplayPort DevCon Presentation, eDP, Dec 2010 v3
For panel sizes up to 1680x1050 with 18 bit color (Power and Ground wires ... Frame Rate: 60Hz 120Hz FHD+ 1920 x 1200 40 signal wires 24-bit, Quad Ch 4 signal wires (2-lane) ... Evolution of the eDP Specification eDP Specification versions and new features introduced eDP Version Primary New Features VESA
Tags:
Specification, Presentation, Size, Frame, Devcon, Displayport, Displayport devcon presentation
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
DisplayPortTM Ver.1.2 Overview - VESA
www.vesa.org33 • Only one DisplayPort Standard specification version number active at any given time • With the publication of DisplayPort Standard Specification Ver.1.2
Overview, Save, Displayporttm ver, Displayporttm, 2 overview vesa
VESA Flat Display Mounting Interface (FDMI) …
www.vesa.orgVESA Flat Display Mounting Interface (FDMI) Overview General The purpose of this standard is to define mounting interface standards for Flat Displays (FDs) such as flat panel monitors, flat displays and flat TVs.
General, Display, Overview, Interface, Mounting, Display mounting interface, Fdmi, Overview general
VESA% DisplayPort%Alt%Mode%% …
www.vesa.orgVESA Confidential USB!Type?C!Receptacle!Pins! 6 Below%is%adiagram%of%the%pins%defined%for%system%or%device%receptacle% Cable% Ground% Cable% BusPower
ICCE Presentation on VESA DisplayPort, Jan 10 2010, …
www.vesa.orgOverview Products • DisplayPort • next years – PC projectors • GPU and notebooks • applications • internal LVDS • applications • and large
DP PHY layer Testing Challenges Agilent
www.vesa.orgDisplay Port Physical Layer Testing Challenges) Agilent Technologies Testing Overview Jim Choate
Challenges, Testing, Overview, Early, Agilent, Phy layer testing challenges agilent, Layer testing challenges, Testing overview
DisplayPort Derivatives: eDP and MyDP and …
www.vesa.orgDisplayPort Derivatives: eDP and MyDP and Considerations of Physical Layer Test Brian Fetz May 6th, 2013
Derivatives, Displayport, Displayport derivatives, Edp and mydp and, Mydp
VESA and DP Certification
www.vesa.orgVESA and DisplayPort Certification Bob Crepps Technical Marketing Engineer VTM, Inc. April 30, 2012 1
Bylaws of the Video Electronics Standards Association
www.vesa.orgVESA Bylaws Nov. 3, 2014 Page 1 of 15 ARTICLE I Name, Office, Purposes, Restrictions 1.01 Name The name of this organization is Video …
New VESA® Direct Drive Monitor Panel Standard Set; Defines ...
www.vesa.orgNew VESA® Direct Drive Monitor Panel Standard Set; Defines Minimum Functionality and Connector Configuration Milpitas, Calif., Mar. 23, 2009 – The Video Electronics Standards Association (VESA) today released a new
Configuration, Drive, Direct, Minimum, Connectors, Define, Functionality, Direct drive, Defines minimum functionality and connector configuration
DisplayPort DevCon Presentation, eDP, Dec 2010 v3
www.vesa.orgPCB trace and data signal wire count is reduced (smaller cable) ! Signal type more compatible with new chip processes ! eDP can use a DisplayPort GPU interface, no separate video port needed ! Overall system power is reduced, increasing battery life ! Lower EMI which means less system shielding requirement
Related documents
NVIDIA GRID vPC Sizing Guide
www.nvidia.com2.1.2 Test Metrics – Frame buffer Usage ... factors, including number of applications, the types of applications, file sizes and number of ... This specification used the NVIDIA nVector as the testing framework for executing a typical knowledge worker workload which simulates application
Omni ision Preliminary Datasheet Advanced Information
web.mit.eduThe OV7670/OV7171 provides full-frame, sub-sampled or windowed 8-bit images in a wide range of ... • Supports image sizes: VGA, CIF, and any size scaling down from CIF to 40x30 ... Specification for detailed usage of the serial control port.
SPECIFICATION FOR CHAIN LINK FENCE AND GATES
ss.usembassy.govC. ASTM A824 Specification for Metallic-Coated Steel Marcelled Tension Wire for ... dimensions, location of gates and opening sizes, cleared area, elevation of fence, gates, footings, and details of attachments ... Gate frame members shall be a minimum of 48.3 . mm (1.90 in.) O.D. schedule 40 galvanized steel pipe, in compliance with ...
American Craftsman 70 Series Double-Hung Window Sizes
homedepot.plygemwindows.com• Window Dimension" always refers to inside frame to frame dimension. • "Minimum Rough Opening" dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. Meet or exceed clear opening area of 5.7 sq.ft., clear opening width of 20" and clear opening height of 24". Cottage Reverse Cottage
COMPANION TO THE AISC STEEL CONSTRUCTION MANUAL
www.aisc.orgdesign procedures, and the breadth of the AISC Specification. The chapters of Part II are labeled II-A, II-B, II-C, etc. Part III addresses aspects of design that are linked to the performance of a building as a whole. This includes coverage of lateral stability and second-order analysis, illustrated through a four-story braced-frame and moment-
SPECIFICATION FOR FILTERS, AIR (HVAC)
files.nc.gov-5- 4130-1Y Specification StyleNominal Filter Size (Inches) (W x H x D) 1 filters– Ring and link panel; two-ply filter with internal wire frame 24x24 Air Flow Capacity (CFM) 1180 Filter Face Air Velocity (FPM) 295 Maximum Initial Resistance (Inches W.G.) 0.28 Minimum Rated Final Resistance (Inches W.G.) 1.0
Disconnect Switch and Circuit Breaker Mechanism ...
literature.rockwellautomation.com4 Rockwell Automation Publication 1494-TD001E-EN-P - February 2016 Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin 1494C, 1494F, 1494G, 1494R, 1494V Disconnect Switches Disconnect Switch Electrical Ratings
CHAPTER 5: Design of Wood Framing - HUD USER
www.huduser.govChapter 5 - Design of Light-Wood Framing inches by 9.25 inches, and a 1x4 is 3/4-inch by 3.5 inches. This guide uses nominal member size, but it is …