Documentation EtherCAT System Terminals

Documentation | ENEL9xxxEtherCAT System Terminals2022-11-23 | Version: of contentsEL9xxx3 Version: of contents1 Overview EtherCAT System and Function on the issue identification of EtherCAT notes on identification of EL Identification Code (BIC).. access to the BIC (eBIC).. Bus 163 Product , EL9012, , EL9012, EL9080 - Introduction and Technical - Introduction and Technical , EL9110, , EL9110, EL9190 - Introduction and Technical , , EL9160 - Introduction and Technical - Introduction and Technical , EL9182, , EL9182, EL9183 - Introduction and Technical , EL9185, EL9185-0010, EL9186, EL9187, EL9188, , EL9185, EL9185-0010, EL9186, EL9187, EL9188, EL9189 - Introduction andTechnical - Introduction and Technical , EL9210, , EL9210, EL9290 - Introduction and Technical , , EL9260 - Introduction and Technical , , EL9410 - Introduction and Technical , EL9540-0010, EL9550, EL9550-0010.

EL9185-0010 [} 36] (Potential distribution terminals, 2 x 4 channels, potential supply function up to 230 V AC) ... All the components are supplied in particular hardware and software configurations appropriate for the ... which is available for download from the Beckhoff web site. From 2014/01 the revision is shown on the outside of the IP20 ...

Tags:

  Distribution, Software, Woodland

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Documentation EtherCAT System Terminals

1 Documentation | ENEL9xxxEtherCAT System Terminals2022-11-23 | Version: of contentsEL9xxx3 Version: of contents1 Overview EtherCAT System and Function on the issue identification of EtherCAT notes on identification of EL Identification Code (BIC).. access to the BIC (eBIC).. Bus 163 Product , EL9012, , EL9012, EL9080 - Introduction and Technical - Introduction and Technical , EL9110, , EL9110, EL9190 - Introduction and Technical , , EL9160 - Introduction and Technical - Introduction and Technical , EL9182, , EL9182, EL9183 - Introduction and Technical , EL9185, EL9185-0010, EL9186, EL9187, EL9188, , EL9185, EL9185-0010, EL9186, EL9187, EL9188, EL9189 - Introduction andTechnical - Introduction and Technical , EL9210, , EL9210, EL9290 - Introduction and Technical , , EL9260 - Introduction and Technical , , EL9410 - Introduction and Technical , EL9540-0010, EL9550, EL9550-0010.

2 EL9550-0012 .. , EL9540-0010, EL9550, EL9550-0010, EL9550-0012 - Introduction and , EL9550 - application , EL9550 - application - Introduction and Technical 764 Basics 78 Table of contentsEL9xxx4 Version: cabling State 805 Mounting and for ESD - Special conditions (standard temperature range).. - Special conditions (extended temperature range).. - Special Documentation for ATEX and - Special Documentation for on mounting instructions for enhanced mechanical load - Power of passive 1066 TwinCAT System with TwinCAT System Manager - passive AL Status compatibility - passive and 110 Overview EtherCAT System and Function terminalsEL9xxx5 Version.

3 EtherCAT System and FunctionterminalsEL9011 [} 20] (End cap)EL9012 [} 20] (End cap)EL9070 [} 23] (Shield terminal)EL9080 [} 20] (Separation terminal)EL9100 [} 25] (Feed terminal, 24 VDC)EL9110 [} 25] (Feed terminal, 24 VDC, with diagnosis)EL9150 [} 29] (Feed terminal, 230 VAC [120 VAC])EL9160 [} 29] (Feed terminal, 230 VAC [120 VAC], with diagnosis)EL9180 [} 32] (Potential distribution terminal, 2 terminal points per power contact)EL9181 [} 35] (Potential distribution terminal, 2 separated potentials)EL9182 [} 35] (Potential distribution terminal, 8 separated potentials)EL9183 [} 35] (Potential distribution terminal, 1 potential, 16 terminal points)EL9184 [} 39] (Potential distribution Terminals , 2 x 8 channels)EL9185 [} 39] (Potential distribution Terminals , 2 x 4 channels)EL9185-0010 [} 39] (Potential distribution Terminals , 2 x 4 channels, potential supply function up to 230 VAC)EL9186 [} 39], EL9187 [} 39] (Potential distribution Terminals , 8 channels)EL9188 [} 39], EL9189 [} 39] (Potential distribution Terminals , 16 channelsEL9190 [} 25] (Feed terminal, up to 230 V AC/DC)EL9195 [} 49] (Shield terminal, up to 230 V AC/DC)EL9200 [} 52] (Feed terminal, fused, 24 VDC)EL9210 [} 52] (Feed terminal, fused, 24 VDC, with diagnosis)EL9250 [} 56] (Feed terminal, fused, 230 VAC))

4 EL9260 [} 56] (Feed terminal, fused, 230 VAC, with diagnosis)EL9290 [} 52] (Feed terminal, fused, up to 230 VAC)EL9400 [} 59] (Power supply unit terminal for E-bus)EL9410 [} 59] (Power supply unit terminal for E-bus with diagnosisEL9540 [} 63] (Surge filter field supply)EL9540-0010 [} 63] (Surge filter field supply for analog Terminals with diagnostics)EL9550 [} 63] (Surge filter System and field supply)EL9550-0010 [} 63] (Surge filter System and field supply for digital Terminals with diagnostics)EL9550-0012 [} 63] (Surge filter System and field supply with up to 10 A)EL9570 [} 73] (Buffer capacitor terminal)ForewordEL9xxx6 Version: on the documentationIntended audienceThis description is only intended for the use of trained specialists in control and automation engineering whoare familiar with the applicable national is essential that the Documentation and the following notes and explanations are followed when installingand commissioning these is the duty of the technical personnel to use the Documentation published at the respective time of eachinstallation and responsible staff must ensure that the application or use of the products described satisfy all therequirements for safety, including all the relevant laws, regulations, guidelines and Documentation has been prepared with care.)

5 The products described are, however, constantly reserve the right to revise and change the Documentation at any time and without prior claims for the modification of products that have already been supplied may be made on the basis of thedata, diagrams and descriptions in this , TwinCAT , TwinCAT/BSD , TC/BSD , EtherCAT , EtherCAT G , EtherCAT G10 , EtherCAT P ,Safety over EtherCAT , TwinSAFE , XFC , XTS and XPlanar are registered trademarks of and licensed byBeckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use bythird parties for their own purposes could violate the rights of the PendingThe EtherCAT Technology is covered, including but not limited to the following patent applications andpatents: EP1590927, EP1789857, EP1456722, EP2137893, DE102015105702 with correspondingapplications or registrations in various other is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Beckhoff Automation GmbH & Co.

6 KG, reproduction, distribution and utilization of this document as well as the communication of its contents toothers without express authorization are will be held liable for the payment of damages. All rights reserved in the event of the grant of apatent, utility model or : instructionsSafety regulationsPlease note the following safety instructions and explanations!Product-specific safety instructions can be found on following pages or in the areas mounting, wiring,commissioning of liabilityAll the components are supplied in particular hardware and software configurations appropriate for theapplication. Modifications to hardware or software configurations other than those described in thedocumentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.

7 QualificationThis description is only intended for trained specialists in control, automation and drive engineering who arefamiliar with the applicable national of instructionsIn this Documentation the following instructions are used. These instructions must be read carefully and followed without fail! DANGERS erious risk of injury!Failure to follow this safety instruction directly endangers the life and health of persons. WARNINGRisk of injury!Failure to follow this safety instruction endangers the life and health of persons. CAUTIONP ersonal injuries!Failure to follow this safety instruction can lead to injuries to to environment/equipment or data lossFailure to follow this instruction can lead to environmental damage, equipment damage or data or pointerThis symbol indicates information that contributes to better : issue statusForewordEL9xxx9 Version.

8 EL9540 and EL9550, application example added- Update Update chapter "Technical data"- Update Update chapter "LEDs and connection"- Update EL9450-0010, EL9550-0010 added- Update chapter "Technical data"- Update Update chapter "Technical data"- Update EL9185-0010, EL9550-0012 and EL9180 added- Update chapter "Technical data"- Update Chapter Non-reactive Bus Terminals added- Update chapter "Technical data"- Update Addenda EL9185- Update chapter "Technical data"- Update Update chapter "Technical data"- Update Update chapter "Technical data"- Update Update chapter "Introduction"- Update Update chapter "Technical data"- Update Update chapter "Technical data"- Update chapter "Introduction"- Update Update chapter "Technical data"- Addenda chapter "Installation instructions for enhanced mechanical load capacity"- Update Update structure- 1st public issue in PDF Update Technical data Technical data added.

9 Update Technical Update connection diagram Addenda EL9540, Technical data EL9070, EL9181, EL9182, EL9183 Technical data EL9195 Firmware compatibility note Technical data added, EL9184, EL9188, EL9189 Technical data added, EL9190, EL9200, EL9210, EL9250, EL9260, EL9290 Technical data EL9150, EL9160 Technical data EL9110, EL9410 Technical data EL9100 Technical data EL9186, EL9187 Technical data first provisional Documentation for EL9xxxForewordEL9xxx10 Version: identification of EtherCAT notes on markingDesignationA Beckhoff EtherCAT device has a 14-digit designation, made up of family key type version revisionExampleFamilyTypeVersionRevision EL3314-0000-0016EL terminal(12 mm, non-pluggable connectionlevel)3314 (4-channel thermocoupleterminal)0000 (basic type)0016ES3602-0010-0017ES terminal(12 mm, pluggableconnection level)3602 (2-channel voltagemeasurement)0010 (high-precision version)0017CU2008-0000-0000CU device2008 (8-port fast ethernet switch)0000 (basic type)0000 Notes The elements mentioned above result in the technical designation.

10 EL3314-0000-0016 is used in theexample below. EL3314-0000 is the order identifier, in the case of -0000 usually abbreviated to EL3314. -0016 is theEtherCAT revision. The order identifier is made up of- family key (EL, EP, CU, ES, KL, CX, etc.)- type (3314)- version (-0000) The revision -0016 shows the technical progress, such as the extension of features with regard to theEtherCAT communication, and is managed by principle, a device with a higher revision can replace a device with a lower revision, unless specifiedotherwise, in the and synonymous with each revision there is usually a description (ESI, EtherCAT SlaveInformation) in the form of an XML file, which is available for download from the Beckhoff web site.