DynaPak Gas SamplerS Y S T E M S U P P O R T M A N U A LDP-2000 XDP-2000 XINSTRUCTION & OPERATINGMANUALV ersion: 071120051. Introduction72. System Components73. Theory of Operation84. Sampler Location95. Sampler Installation106. Sample Vessel Installation117. Operational Check & Leak Testing128. Sampler Set-Up:139. Sampler Maintenance1410. Diagrams#1DP-2000 pump (assembled)17#2DP-2000 pump (exploded)18#3YZ filter regulator (assembled)19#4YZ filter regulator (exploded)20#5 LinkPlus21#6 DuraSite constant pressure22sample vesselTable Of ContentsPage 6YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version 09092002DP-2000 Version 09092002YZ Systems , Inc.

1. Introduction 7 2. System Components 7 3. Theory of Operation 8 4. Sampler Location 9 5. Sampler Installation 10 6. Sample Vessel Installation 11

Tags:

  Sampler, Dynapak, Dynapak gas sampler

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DynaPak Gas Sampler - YZ Systems

1 DynaPak Gas SamplerS Y S T E M S U P P O R T M A N U A LDP-2000 XDP-2000 XINSTRUCTION & OPERATINGMANUALV ersion: 071120051. Introduction72. System Components73. Theory of Operation84. Sampler Location95. Sampler Installation106. Sample Vessel Installation117. Operational Check & Leak Testing128. Sampler Set-Up:139. Sampler Maintenance1410. Diagrams#1DP-2000 pump (assembled)17#2DP-2000 pump (exploded)18#3YZ filter regulator (assembled)19#4YZ filter regulator (exploded)20#5 LinkPlus21#6 DuraSite constant pressure22sample vesselTable Of ContentsPage 6YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version 09092002DP-2000 Version 09092002YZ Systems , Inc.

2 3101 Pollok Drive Conroe, Texas USA 77303 P: F: 7 Congratulations on your purchase of the DynaPak 2000 Series Gas Sampler . You've made a wise measurementinvestment for your you begin installation, insure that all of the necessarycomponents are present. You will need a samplecylinder(s) during the installation. If you have questionsconcerning installation/operation, contact your YZ representativeor YZ Customer Service at contained in this document is subject to changewithout notice and does not represent a commitment on thepart of YZ System ComponentsThe primary components of the DynaPak 2000 Sampling System are illustrated IntroductionZ-65 ControllerCable Entry FittingSolenoid ValvePatents 5,152,678; 4,531,895.

3 4,928,536 Wiring and Pneumatic Tubing NotShown For Drawing ClaritySample Inlet10 1/2" (27 cm)8 1/2" (22 cm)1949 FactorySystemApprovedMutualSample DischargeDynaPak 3000 PumpTubingPurge ValveIsolation ValveSample DischargeProbe Body AssemblyNote:Filter/RegulatorYZ Systems , POLLOK CONROE, TEXAS 773031/2" NPTDP-2010 XDynaPak 2000 PumpPage 8YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version 09092002 DynaPak 2000 Gas SamplerThe DynaPak 2000 Sampler is a pipeline mounted systemwhich uses the pneumatically operated, positivedisplacement DynaPak 2000 pump, the YZ filter/regulatorand a low power solenoid valve to obtain gas system may be operated at pipeline pressuresbetween 25 psig ( Bar) and 1500 psig ( Bar).

4 The DynaPak 2000 Pump is adjustable from 0 to .4 cc/stroke. The pump is actuated by pipeline gas which passesthrough a filter/regulator and to a 12 VDC solenoid. Thesolenoid strokes the pump each time it is energized by Theory of OperationDP-2000 Version 09092002YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: The Sampler should be a minimum of five pipediameters from any device which could cause aerosols orsignificant pressure The Sampler should not be located within the definedmeter tube region (AGA 3-1985 ED.).A = The number of unobstructed, straight pipe diametersupstream (see AGA - 3 manual).

5 B = The number of unobstructed, straight pipe diametersdownstream (see AGA - 3 manual). Meter Tube Optimum Sampler Probe LocationsDifferential Pressure Device5 Flow A B 5 4. Sampler LocationPage 10YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version DynaPak 2000a. The DynaPak 2000 Sampler should be mounted verticallyin a horizontal run of the The end of the Sampler probe should penetrate thecenter 1/3rd of the The end of the sample probe should be cut parallelto the Connect 12 VDC actuation signal wires to the solenoidwires inside the enclosure. The positive lead connects tothe red wire and the negative lead connects to the Before applying pipeline pressure to the DynaPak 2000,ensure that the isolation valve and purge valve are After pipeline pressure has been applied to the Sampler ,check the probe body/pipeline connection using a liquidleak 1/4" stainless steel tubing must be connected from asource of supply actuation gas with a minimum pressure of65 psig to the external gas supply connection for the FilterRegulator located on the left side of the Sampler .

6 Incorrect operation of valves (over tightening)can result in damage to the valve components(isolation valve bonnet assembly) which mightresult in the valve stem being screwed out of theprobe body. This of course results in product atpipeline pressure being vented continuallythrough this port until this section of the pipelineis shut in. Be aware of the following proceduresand information. DynaPak valves are of soft seatdesign and should only be closedor opened with fingers. Nowrenches should ever be used. If a valve will not seal off withfinger tight operation the valveshould have maintenanceperformed to allow properoperation of the System InstallationCenter 1/31/31/31/3 Center 1/31/31/31/3 ExternalGas SupplyConnectionDP-2000 Version 09092002YZ Systems , Inc.

7 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Spun Cylinders. Spun cylinders may be installed in ahorizontal position on the DynaPak BackRack vessel traps in the line, install stainless steel tubing andfittings from the sample discharge port of the Sampler to theproduct end of the sample Variable volume/constant pressure cylinderThe free-floating piston cylinder (DuraSite) may be installedin a horizontal position on an optional vessel rack. Free-floating piston cylinders should NOT be installed on theDynaPak BackRack vessel 1/8" tubing from the sample discharge port of themanifold to the product end of the vessel.

8 Avoid traps in vessel may be pre-charged using bottled inert gas suchas nitrogen or helium (consult the factory for properprocedure). LinkPlus. Install the optional LinkPlus directly into thesample discharge port of the Sampler . Use stainless steeltubing and fittings to connect the LinkPlus outlet to theproduct end of the sample Sample Vessel InstallationPage 12YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version When all of the tubing connections have been completed,close the purge valve on the front of the Sampler probe the sample probe supply valve to allow pipelinepressure into the Sampler .

9 Check all connections using aliquid leak Adjust the filter/regulator from the following ranges:Pipeline PressureActuation Pressure25 psig ( Bar) to50 psig ( Bar)Pipeline Pressure50 psig ( Bar) to700 psig (48 Bar)50 psig ( Bar)Over 700 psig (48 Bar) to1500 psig ( Bar)65 psig ( Bar) Turn the stroke adjustment knob on the top of the pumpcounterclockwise to set the pump displacement Utilizing the customer supplied control function initiatestroking of the actuation solenoid at a rapid rate until pipelinepressure plus is achieved at the sample Check all connections from the Sampler discharge to theconnection on the sample cylinder using a liquid If no leaks are found, the pump and tubing should beconsidered tested and Operational Check & Leak TestingDP-2000 Version 09092002YZ Systems , Inc.

10 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Calculate the sampling rate using the following 30 Adjust the pump volume adjustment knob to the valueused in the calculations in step of turns open on the pump volume knob3612 Sample pump displacement per of turnsopen on pumpstroke knobsamplepumpdisplacementper stroke1000 cc500 cc300 ccSample cylinder volumesSamplerate(minutes)8. Sampler Set-UpPage 14YZ Systems , Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: F: Version Recommended preventative maintenance scheduleEvery sampling situation is unique.