Example: biology

E3MAC-1P - Isolite

COMMENTS:DATE:PROJECTISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC Inverter1. SERIESORDERING INFORMATIONE3 MAC-1000-1P-LC-IA-OA-C##-O##-S##-------- 10001000 VA Single Phase50005000 VA Single Phase16001600 VA Single Phase60006000 VA Single Phase22002200 VA Single Phase80008000 VA Single Phase428002800 VA Single Phase1000010000 VA Single Phase430003000 VA Single Phase1250012500 VA Single Phase440004000 VA Single Phase1 PSingle PhaseIA120 VIB277 VIC208V3IE480V3OA120 VOB277V2. VA RATING10. OPTIONS3. PHASE5. INPUT VOLTAGE6. OUTPUT VOLTAGEE3 MAC1 PFEATURES Optional Web-based Monitoring Platform easily view, interact with, download and manage records as needed on any PC or mobile device Programmable and password protected user interface 98% efficient for minimal BTU losses PWM Inverter provides pure sine wave output with less than 3% THD Crest factor >4 overload protection for demanding high in-rush loads Programmable transfer time select between standard and fast transfer times for load and site compatibility UL listed 90 minute run-time Compatible with all lighting loads, including HID Variabl

Batteries are not included in the extended warranty. Due to power factor calculations, we recommend only loading the E3MAC inverter to 90% of load wattage. For Two Phase, Three Phase, or Split Phase, see E3MAC-3P, E3MAC-2P, or E3MAC-SP 10,000 and 12,500 VA only available with 277V input/output ACCESSORIES; ORDER SEPARATELY

Tags:

  Power, Batteries

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of E3MAC-1P - Isolite

1 COMMENTS:DATE:PROJECTISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC Inverter1. SERIESORDERING INFORMATIONE3 MAC-1000-1P-LC-IA-OA-C##-O##-S##-------- 10001000 VA Single Phase50005000 VA Single Phase16001600 VA Single Phase60006000 VA Single Phase22002200 VA Single Phase80008000 VA Single Phase428002800 VA Single Phase1000010000 VA Single Phase430003000 VA Single Phase1250012500 VA Single Phase440004000 VA Single Phase1 PSingle PhaseIA120 VIB277 VIC208V3IE480V3OA120 VOB277V2. VA RATING10. OPTIONS3. PHASE5. INPUT VOLTAGE6. OUTPUT VOLTAGEE3 MAC1 PFEATURES Optional Web-based Monitoring Platform easily view, interact with, download and manage records as needed on any PC or mobile device Programmable and password protected user interface 98% efficient for minimal BTU losses PWM Inverter provides pure sine wave output with less than 3% THD Crest factor >4 overload protection for demanding high in-rush loads Programmable transfer time select between standard and fast transfer times for load and site compatibility UL listed 90 minute run-time Compatible with all lighting loads, including HID Variable time delay Battery recharges in less than 24 hours Single phase output Start-up diagnostics checks for proper installationSEISMIC CERTIFIED Optional Zone 4 Seismic Restraints are shaker table tested and seismic certified to the latest California Building Code (CBC)

2 2016 The shake table testing was performed in accordance with International Code Council-Evaluation Service Acceptance Criteria 156 (ICC-ES AC156) OSHPD (California Office of Statewide Health Planning and Development)7. OUTPUT BREAKER - NORMALLY ON*8. OUTPUT BREAKER - NORMALLY OFF*9. OUTPUT BREAKER - SWITCHED*BLANK = NO OPTIONMBM aintenance Bypass SwitchEEWE xtended Electronics WarrantyTBProgrammable Terminal Block (Not Included with RA)BTMSB attery Thermal Management SystemCBCustom BreakerKEKeyed EnclosureZ4 Seismic Zone 4 Restraints (Includes KE)EOEmergency power OffDTDelayed TransferTATrip Alarm with BreakerWBWall Mounting Bracket1 WEBWeb Monitoring Connection2 EBW20 Extended Battery WarrantyRARemote Annunciator (Not Included with TB)BIBMS IntegrationSEE BREAKER CONFIGURATION TABLE ON PAGE 3 FOR MAXIMUM BREAKERSC** Normally On BreakersO** Normally Off BreakersS** Switched BreakersNOTEM aximum number of OUTPUT breakers supported depends on sizing and option selection.

3 Contact factory for specific NOTES1. WB option only available on 1 KVA In order to use the web-based monitoring available at , the -WEB option must be Upon special request, requires extra transformer(s), cabinet configuration may Indicated VA ratings may be ordered as a stacked unit using Configuration H. This configuration is not seismic certified. Contact factory for specific Calcium4. BATTERY TYPELCACCESSORIES ON NEXT PAGEISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC InverterOPTIONAL FEATURES Maintenance bypass switch Circuit breakers supervised or unsupervised Maintenance contract/plan Remote Annunciator Factory startup increases electronics warranty to 3 years Circuit breaker protected loads (switched, normally on, and normally off) Fault summary alarm and 2 programmable alarms form C dry contacts Keyed lockable enclosureFRONT PANEL Modern 4x20 LCD character display with white LED back-light Heads-up diagnostic LEDs include 5 status (AC present, battery charging, inverter power , system ready, switched load energized)

4 , fault summary LED, and 5 specific faults (unit in bypass, circuit breaker trip, startup fault, charger fault, inverter fault) Dedicated System Test button initiates 30-second test with UL compliant diagnostics 5-button keypad for menu navigation Sonic alarm with dedicated enable/disable pushbutton with heads-up LED. Alarm silence has 24-hour ring-back for alarm reminder SD memory card download and store all events, tests, and alarm logs (password protected) USB connector access to all event, tests, and alarm logs (password protected) Ethernet 10 BASE-T, TCP/IP web servingBATTERY Front access VRLA batteries with 10-Year pro-rated warrantyTEMPERATURE RATING From 68 F to 86 FBattery service life will be negatively impacted at ambient temperatures above 77 FENVIRONMENTAL Operating temp: 20C to 30C (68 F to 86 F) Storage temp: Electronics - 20C to 70C (68 F to 158 F) Relative humidity: <95 % (non-condensing)MAINTENANCE PLAN Once per year the manufacturer s technician shall visit the site to perform maintenance and software upgrades as needed.

5 Maintenance shall include battery voltage checks, torque setting verification, cleaning, and a thorough visual inspection. All electronics warranties shall be extended to the duration of the Maintenance Plan. Maintenance Plans can be purchased for a duration of 1 year to 5 UL 924 OSHPD Seismic Certified (with Z4 option) New York City Approved, Calendar Number 51575 NFPA 101 Life Safety Code NFPA 70-NEC OSHA NEMA Type 1 enclosureBMS INTEGRATION BACNet IP BACNet MS/TP Modbus TCP Modbus RTUWARRANTY Isolite warrants the E3 MAC series electronics assembly against defects in material and workmanship for a period of 2 years, or 3 years with factory startup option. Extended Warranty options available. Isolite warrants the E3 MAC series lead calcium batteries for a 1-year full and 9-year pro-rated limited warranty. For further details, refer to General Warranty and Obligations in the Isolite manual or on our website.

6 The EEW option extends the electronics warranty to 5 years. batteries are not included in the extended STORAGE TEMP51 F (11 C) TO 77 F (25 C)180 DAYS78 F (26 C) TO 92 F (33 C)90 DAYSACCESSORIES; ORDER SEPARATELYACCESSORIES; ORDER SEPARATELY E3 MAC-MP# = Maintenance Plan plus number of years (#)SPECIFICATIONSISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC InverterWEIGHT & DIMENSIONSM odelCabinet Config (See Next Page)# of CabinetsInverter Cabinet WeightBattery Cabinet WeightBattery CountPallet CountTotal WeightE3 MAC-1000-1PA130841343E3 MAC-1600-1PG141461549E3 MAC-2200-1PG149281627E3 MAC-2800-1PG1570101705E3 MAC-3000-1PG1648121783E3 MAC-4000-1PB1995821060E3 MAC-5000-1PB111551021220E3 MAC-6000-1PB112801221380E3 MAC-8000-1PE/H240015701632020E3 MAC-10000-1PE/H240018902032340E3 MAC-12500-1PE/H240022102432660 ELECTRICAL DATAM odelPower Rating (kW)

7 Minimum Feed BreakerSuggested Feed BreakerFull Load BTU/HrInput Voltage IAInput Voltage IBInput Voltage ICInput Voltage IDInput Voltage IEInput Voltage IAInput Voltage IBInput Voltage ICInput Voltage IDInput Voltage A20 A20 A20 A20 A20 A30 A20 A20 A20 A20 A30 A20 A20 A20 A20 A40 A20 A30 A20 A20 A40 A20 A30 A20 A20 A60 A30 A40 A30 A20 A70 A30 A40 A40 A20 A80 A40 A50 A40 A20 A110 A50 A60 A80 A852 MAXIMUM BREAKERSM odel# of Breakers Normally On# of Breakers Normally On with TA# of Breaker Normally Onwith MB# of Breaker Normally On with EO# of Breakers Normally On with TA + MB# of Breakers Normally On with MB + EO# of Breakers Normally On with TA + EO# of Breakers Normally On with TA + MB + EO# of BreakersNormally Off# of BreakersSwitchedE3 MAC-1000-1P8577464344E3 MAC-1600-1P1171010696566E3 MAC-2200-1P1171010696566E3 MAC-2800-1P1171010696566E3 MAC-3000-1P1171010696566E3 MAC-4000-1P12811117107644E3 MAC-5000-1P12811117107644E3 MAC-6000-1P12811117107644E3 MAC-8000-1P24162323152215141212E3 MAC-10000-1P24162323152215141212E3 MAC-12500-1P24162323152215141212 Isolite Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ACONFIGURATION BE3 MAC-1P1,000-12,500 VA Single Phase Modular AC Inverter13 24 24 TOPTOP38 4 Master Inverter CabinetMaster Inverter CabinetFRONT23 32 32 50 4 FRONT13 24 24 TOPTOP38 4 Master Inverter CabinetMaster Inverter CabinetFRONT23 32 32 50 4 FRONTDIAGRAMSISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN.

8 PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC InverterCONFIGURATION ECONFIGURATION 4 55 32 32 Master Inverter CabinetFRONTTOP32 32 32 32 50 4 23 Master Inverter CabinetBattery CabinetFRONTFRONTTOPTOPDIAGRAMS (CONTINUED) Isolite Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE ,000-12,500 VA Single Phase Modular AC InverterCONFIGURATION HDIAGRAMS (CONTINUED) MIN CLEARANCE IN FRONT OF CABINET (NOT TO SCALE) TOTAL CLEARANCELEFT SIDE KNOCKOUT PATTERN IDENTICAL TO RIGHT TOTAL CLEARANCE INCLUDING WALL SURFACES ON BOTH MIN CLEARANCE ON BOTH SIDES OF CABINET (NOT TO SCALE)BATTERY CABINETINVERTER " " "MMICONTROLPANEL24 CIRCUIT BREAKERPANEL " " " " " " " " " TOTAL CLEARANCE INCLUDING WALL SURFACES ON BOTH MIN CLEARANCE ON BOTH SIDES OF CABINET (NOT TO SCALE)3X "2X "2X " " "BOTTOMFLOOR MOUNTINGBOLT PATTERN.

9 40"6X PER CABINET MOUNTING HOLESISOLITE Isolite HEADQUARTERS 31 WATERLOO AVENUE BERWYN, PA 19312 Isolite WEST 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA REV-15 20231221 SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT Isolite FOR UP TO DATE INTERFACE POINTS LISTE3 MAC-1P1,000-12,500 VA Single Phase Modular AC InverterPOINT NAMEBACNET OBJECT TYPEBACNET OBJECT IDMODBUS REGISTERI nverterBI110001 ChargerBI210002AC PresentBI310003 ReadyBI410004 Switched LoadBI510005 Alarm SummaryBI610006 BypassBI710007 Circuit Breaker TipBI810008 Startup FaultBI910009 Charger FaultBI10100010 Inverter FaultBI11100011 Input Voltage (Phase A)AI130001/30002 (FLOAT)Input Voltage (Phase B)AI230003/30004 (FLOAT)Input Voltage (Phase C)AI330005/30006 (FLOAT)Output Voltage (Phase A)AI430007/30008 (FLOAT)Output Voltage (Phase B)AI530009/30010 (FLOAT)Output Voltage (Phase C)AI630011/30012 (FLOAT)Output Current (Phase A)AI730013/30014 (FLOAT)Output Current (Phase B)AI830015/30016 (FLOAT)Output Current (Phase C)AI930017/30018 (FLOAT)Battery VoltageAI1030019/30020 (FLOAT)Battery CurrentAI1130021/30022 (FLOAT)TemperatureAI1230023/30024 (FLOAT)Output VA (Phase A)AI1330101/30102 (UINT32)Output VA (Phase B)AI1430103/30104 (UINT32)Output VA (Phase C)AI1530105/30106 (UINT32)Battery PowerAI1630107/30108 (UINT32)System Runtime (Days)AI1730109/30110 (UINT32)Inverter Runtime (Minutes)AI1830111/30112 (UINT32)Inverter Runtime (Seconds)AI1930113/3014 (UINT32)System EventsAI2030115/30116 (UINT32)


Related search queries