Example: confidence

Eaton’s IQ 35M energy meter Compact, powerful …

Compac t, powerful energy meterA NEMA 4X enclosure is available as an accessory. This combination is perfect for retrofit metering the rapidly changing emphasis on LEED designs, this meter helps you to meet the Measurement and Verification points required by the LEED and GREEN building models include pulse output, alarm contact and phase loss alarms for maximum versatility. The BACnet version offers two digital inputs for accumulating other meter pulses in place of the digital output and alarm contact. The Modbus output option offers added flexibility for configuration, communication and data IQ 35M allows you to: Verify energy bills Make informed load shifting and shedding decisions Fairly and accurately allocate energy costs to users Identify wasteful practices Decrease unnecessary usage Produce an energy profile Secure the optimum utility rate structureKey features: Economical and compact watt hour meter with demand Backlit LCD display for local reading Compatible with the Power Xpert Gateway for remote monitoring Monitors Voltage, current, power factor, frequency Power and energy : real, reactive and apparent Optional data logging capabi

Compact, powerful energy meter A NEMA 4X enclosure is available as an accessory. This combination is perfect for retrofit metering applications.

Tags:

  Eaton, Energy, Compact, Meters, Powerful, Powerful energy meter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Eaton’s IQ 35M energy meter Compact, powerful …

1 Compac t, powerful energy meterA NEMA 4X enclosure is available as an accessory. This combination is perfect for retrofit metering the rapidly changing emphasis on LEED designs, this meter helps you to meet the Measurement and Verification points required by the LEED and GREEN building models include pulse output, alarm contact and phase loss alarms for maximum versatility. The BACnet version offers two digital inputs for accumulating other meter pulses in place of the digital output and alarm contact. The Modbus output option offers added flexibility for configuration, communication and data IQ 35M allows you to: Verify energy bills Make informed load shifting and shedding decisions Fairly and accurately allocate energy costs to users Identify wasteful practices Decrease unnecessary usage Produce an energy profile Secure the optimum utility rate structureKey features: Economical and compact watt hour meter with demand Backlit LCD display for local reading Compatible with the Power Xpert Gateway for remote monitoring Monitors Voltage, current, power factor, frequency Power and energy .

2 Real, reactive and apparent Optional data logging capability Optional serial communications (Modbus-RTU and BACnet) Revenue grade, ANSI accuracy, IEC 62053-22 Class Compatible with economical solid-core and split-core CTs User-enabled password protection On-board diagnosticsAn ideal solution for panelboard monitoring and retrofit metering applicationsTypical applications Commercial sub-metering energy management Industrial monitoring Cost allocationIntroductionThe eaton IQ 35M meter is a compact , affordable energy meter that combines exceptional performance and easy installation to deliver a cost-effective solution for energy and power monitoring applications, as well as sub-metering of its compact size, the IQ 35M is an ideal solution for panelboard applications to monitor the main power coming into the panelboard.

3 Use the IQ 35M for applications in lighting appliance and small power dis-tribution panelboards up to 400 Amps. In addition, with its small profile, the IQ 35M allows you to stack multi-ple meters in an Integrated Facility System Switchboard application to monitor individual feeder s IQ 35M energy meter Product Diagram Milivolt CT Inputs Phase Loss Alarm or Pulse Input (BACnet)* energy Pulse Output or Pulse Input (BACnet)* Reactive energy Pulse Output, Modbus, or BACnet* Voltage Inputs - Up to 600 VAC L-L Ground Control Power Input - Up to 600 VAC L-L Backlit LCD Display Alarm LED lights when in alarm condition energy LED tied to Pulse Output or Pulse Inputs (BACnet)** Depending on model selectedIQ 35M Panelboard ApplicationThe IQ 35M is the industry s first such product offered as standard for panelboard applica-tions.

4 Because of its compact size, it is an ideal solution to monitor the main power coming into the panelboard. Applications include lighting, appliance and small power distribution panelboards up to 400 CORPORATION eaton s IQ 35M energy meter Comparing IQ 35M ModelsIQ35MA11IQ35MA12IQ35MA13IQ35MA15IQ 35MA22IQ35MA23 InstrumentationCurrent, per phase & averageXXXXXXV oltage, per phase (L-L, L-N) & averageXXXXXXF requencyXXXXXXP owerReal, reactive and apparent power, per phase & total (W, VAR, VA)XXXXXXP ower factor, per phase & averageXXXXXXD emandBlock interval (fixed, sliding)XXXXXXReal, reactive and apparent power demand, present & peakXXXXReal, reactive and apparent power demand, present & positive and negative peakXXEnergyReal, reactive and apparent energy , total (Wh, VARh, VAh)XXXXReal energy , per phase (Wh)

5 XXXXReal energy , per phase, net & total positive & negative (Wh)XXReactive energy , positive and negative quadrant (VARh)XXApparent energy , net & total positive & negative (VAh)XXData Logging Configurable Data BuffersXXXI/OPulse Outputs21111 Alarm Outputs11111 Pulse Inputs2 CommunicationsRS-485, Modbus RTUXXXXRS-485, BACnet MS/TPXIQ 35M meter ordering informationMeter seriesEnergy type1 = Standard energy2 = 4 Quadrant energyOutput option1 = Pulse output only*2 = Pulse output + modbus3 = Pulse output + modbus + data logging5 = Pulse inputs + BACnet + data logging*IQ35M A 1 1* Not available with 4 Quadrant CORPORATION eaton s IQ 35M energy meter DIN mount configurationWall mount configurationVoltage inputUL: 90V (L-N) to 600V (L-L); CE: 90V (L-N) to 300V (L-L)Current inputScaling: 5A to 32,767 AInput range: 0 to or 0 to 1V (selectable)Control power UL: 90V (L-N) to 600V (L-L); CE: 90V (L-N) to 300V (L-L)AccuracyReal power and energy (ANSI , IEC 62053-22 Class )OutputsIQ35 MAx1 thru 3 Real energy pulse: static; alarm contacts: staticIQ35 MAx1 Reactive energy pulse 30 VAC/DCIQ35 MAx2, IQ35 MAx3RS-485 2-wire modbus RTUIQ35MA15RS-485 2-wire BACnet MS/TPInputsIQ35MA15 Two accumulating pulse inputs.

6 Solid-state or mechanical contact (current < 1mA)Min pulse width 20 msecMechanicalMountingDIN Rail or 3-point screw mountEnvironmentalOperating temperature rangeMeter: -30 to 70 C (-22 to 158 F)Display: -10 to 50 C (14 to 122 F)Storage temperature rangeMeter: -40 to 85 C (-40 to 185 F)Display: -10 to 60 C (14 to 140 F)Humidity range<95% RH non-condensingData outputskW, kWhTotalCurrent3-phase average, per phaseVoltage3-phase average, per phase line-line and line-neutralPowerReal, reactive, and apparent; 3-phase total and per phasePower factor3-phase average and per phasePower demandMost recent and peakDemand configurationFixed, rolling block, and external syncData logging (IQ35 MAx3/IQ35MA15 only)10(IQ35 MAx3), 3(IQ35MA15) configurable data buffersConfigurable demand subinterval (when set at a 15-minute interval, buffers store data for 60 days)ComplianceUL/cULUL508 (open type device), Listed 44XJ CSA No.

7 14-05CE EN61010-1:2001 ANSI AccuracyIEC AccuracyROHSD imensional drawingCTs and AccessoriesModel number DescriptionC TsSolid CoreIQ35M-SO-030-5IQ35M CT, Solid Core, 5 , InchIQ35M-SO-030-20IQ35M CT, Solid Core, 20 , InchIQ35M-SO-050-50IQ35M CT, Solid Core, 50 , InchIQ35M-SO-075-50IQ35M CT, Solid Core, 50 , InchIQ35M-SO-125-100IQ35M CT, Solid Core, 100 , InchIQ35M-SO-125-200IQ35M CT, Solid Core, 200 , InchIQ35M-SO-125-250IQ35M CT, Solid Core, 250 , InchIQ35M-SO-125-300IQ35M CT, Solid Core, 300 , InchIQ35M-SO-125-400IQ35M CT, Solid Core, 400 , InchSplit CoreIQ35M-SP-075-5IQ35M CT, Split Core, 5 , InchIQ35M-SP-075-30IQ35M CT, Split Core, 30 , InchIQ35M-SP-075-50IQ35M CT, Split Core, 50 , InchIQ35M-SP-075-100IQ35M CT, Split Core, 100 , InchIQ35M-SP-075-200IQ35M CT.

8 Split Core, 200 , InchIQ35M-SP-125-250IQ35M CT, Split Core, 250 , InchIQ35M-SP-125-300IQ35M CT, Split Core, 300 , InchIQ35M-SP-125-400IQ35M CT, Split Core, 400 , InchIQ35M-SP-125-600IQ35M CT, Split Core, 600 , InchIQ35M-SP-253-800IQ35M CT, Split Core, 800 , InchIQ35M-SP-255-1000IQ35M CT, Split Core, 1000 , InchIQ35M-SP-255-1200IQ35M CT, Split Core, 1200 , InchIQ35M-SP-255-1600IQ35M CT, Split Core, 1600 , InchIQ35M-SP-255-2000IQ35M CT, Split Core, 2000 , InchIQ35M-SP-255-2400IQ35M CT, Split Core, 2400 , InchAccessoriesIQ35M-ENC IQ35M Enclosure, NEMA 4 XIQ35M-FP1 IQ35M Fuse Pack, Single, 1/2A, Slow-BlowIQ35M-FP2 IQ35M Fuse Pack, Double, 1/2A, Slow-BlowIQ35M-FP3 IQ35M Fuse Pack, Triple, 1/2A, Slow-BlowIQ35M-RMC IQ35M Replacement Mounting ClipsIQ35M-DR IQ35M DIN RailIQ35M-DRSC IQ35M DIN Rail Stop Clips (10 Pack)Technical SpecificationsEaton CorporationElectrical Sector1111 Superior , OH 44114 United States877-ETN-CARE (877-386-2273) 2011 eaton CorporationAll Rights ReservedPrinted in USAPA02601011E / TNOctober 2011 eaton and Power Xpert are registered trademarks of eaton Corporation.

9 All other trademarks are property of their respective : Specifications are subject to change without notice and represent the maximum capabilities of the product with all options installed. This is not a complete feature list. Features and functionality may vary depend-ing on selected options, firmware version and product model. Please refer to User Manual for detailed specifications.


Related search queries