Example: tourism industry

Effective: March 2000 Page 1 AMPGARD MV Motor Control ...

Renewal PartsEffective: March 2000 Page MV Motor ControlVacuum BreakSJ SeriesNew InformationSupersedes RPD8855V(August 1994)ContentsPagesGeneral information ..2, 3400-Amp Contactor Design ..4-12(incl. SJA SJS SJD)800-Amp Contactor Design ..13-16400 & 800-Amp Common ..17-19 ComponentsIsolating Switches ..20-23 ADM Switch ..24-26 MBA (Main Breaker AMPGARD ) ..27 Solid State Reduced Voltage ..28-30 Assembly Structure Parts ..31-34 Accessories ..35 Recommended Spare Parts ..36, 37for Stock400 Amp StartersADM Switches800 Amp Starters400 Amp Narrow designRenewal PartsAMPGARD MV Motor ControlVacuum Break SJ SeriesCutler-HammerPage 2 effective : March 26 36 10 36 General InformationRenewal and Replacement PartsThe present design of AMPGARD mediumvoltage starters was introduced in ratings and features have beencontinuously introduced over the renewal parts data will provide theproper identification of standard parts whichmay be required for the maintenance ofCutler-Hammer AMPGARD starters.

Renewal Parts Effective: March 2000 Page 1 RP.48J.01.T.E AMPGARD® MV Motor Control Vacuum Break SJ Series New Information Supersedes RPD8855V (August 1994)

Tags:

  Information, Effective, Part, Pages, March, 2000, March 2000 page 1, Parts effective

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Effective: March 2000 Page 1 AMPGARD MV Motor Control ...

1 Renewal PartsEffective: March 2000 Page MV Motor ControlVacuum BreakSJ SeriesNew InformationSupersedes RPD8855V(August 1994)ContentsPagesGeneral information ..2, 3400-Amp Contactor Design ..4-12(incl. SJA SJS SJD)800-Amp Contactor Design ..13-16400 & 800-Amp Common ..17-19 ComponentsIsolating Switches ..20-23 ADM Switch ..24-26 MBA (Main Breaker AMPGARD ) ..27 Solid State Reduced Voltage ..28-30 Assembly Structure Parts ..31-34 Accessories ..35 Recommended Spare Parts ..36, 37for Stock400 Amp StartersADM Switches800 Amp Starters400 Amp Narrow designRenewal PartsAMPGARD MV Motor ControlVacuum Break SJ SeriesCutler-HammerPage 2 effective : March 26 36 10 36 General InformationRenewal and Replacement PartsThe present design of AMPGARD mediumvoltage starters was introduced in ratings and features have beencontinuously introduced over the renewal parts data will provide theproper identification of standard parts whichmay be required for the maintenance ofCutler-Hammer AMPGARD starters.

2 NOTE:Eaton/Cutler-Hammer acquired theWestinghouse AMPGARD Product Line in 1994. Style numbers identified in thisbrochure may not be the same as stylenumbers on the original equipment. Therenewal part styles in this brochure are in a kit form and may include subassembly,carton, installation instructions, etc. All of the parts shown in the kits are compatiblewith the SJ vacuum design from 1982 tothe present (or noted otherwise).For equipment other than 60 Hz, refer tofactory for and availability of parts not listed may be obtained by contacting your local Cutler-Hammer representative. Provide a completedescription of the part , along with the completedata on the starter nameplate which is foundin the low-voltage area. Be sure to include: ratings, shop order, and diagram Instructions(1) Specify by style number.(2) Refer to Price List/Style Number Index8855 for pricing information , or for Identifying Renewal PartsDetermine the design of the contactor from thecatalog number stamped on the starter name-plate(see pg.)

3 3 for breakdown of catalog no.)OR30 in., 34 in., or 38 in. wide, 100 in. high,and either 30 in. or 60 in. deep. Retrofittingan AMIstarter is possible with the up-to-date AMPGARD components. Refer to 26-000 YES Catalog or refer to factory for designated type H130, H230,H430 (air), and contactors designated K430(oil) were utilized in the AMIstarters. Thesecontactors are obsolete. Refer to factory LF66V430 vacuum contactors shippedprior to 1982 are obsolete and no longeravailable. For replacement, order up-to-dateroll-out design vacuum contactor from page6 which is mechanically and electronicallyinterchangeable with obsolete TypeLF66V430 ServiceShould you experience difficulty in determin-ing needed parts for repair or determiningexisting starter condition, contact your localCutler-Hammer representative. Cutler-Hammer can provide qualified technical personnel on-site to: Identify and recommend replacement parts for damage caused by short circuit or fault. Remove damaged parts and install replacements.

4 Retrofit vintage Motor -starting equipment with new components. Evaluate condition of existing equipment. Test Components. Provide a recommended spare parts list. Upgrade existing unit from one Hp to another or change operating voltage ofexisting equipment. Convert the starter from air break to vacuum break contactor.(1) Determine the ampere rating of your starter by measuring the width of the structure.(2) Determine if it is non-reversing or reversing by measuring the height of the starter cubilce portion of theAmpgard :36 in. width is 400-ampere is contactor with wheels. Slide-Outdesign is contactorwithout in. height is non-reversing in. height is reversing to pages 4, 6-12, 17-19 for to pages 5, 6-12, 17-19 for in. width is 800-ampere in. Height is non-reversing in. height is reversing to pages 13-16, 17-19.(3) Determine the volt amp rating of the con-trol transformer by measuring the heightof the Control transformer.(4) Determine primary voltage; 2300, 4160,etc.

5 This information is on the starter nameplate in the low-voltage area.(5) Now that you have identified the designof your complete contactor determine from the photographs which parts are required and identify them by style numberObsolete AMPGARD DesignsObsolete AMPGARD design starters manufac-tured prior to 1966 were designated AMIstarters and were built in various cities in theUSA. These starters were 1 High design, 45 90 75 90 90 10 40 60 90 10 50 90 400-Amp Vacuum Contactor7200-Volt max. non-reversingRoll-Out or Slide-Out design400-Amp 7200-Volt max. Isolating Switch400-Amp Vacuum Contactor7200-Volt max. reversingRoll-Out or Slide-Out design400-Amp7200-Volt max. Isolating Switch400-Amp Vacuum Contactor7200-Volt max. non-reversingNarrow max. Isolating Switch800-Amp Vacuum Contactor7200-Volt max. non-reversingRoll-Out design800-Amp7200-Volt max. Isolating Switch800-Amp Vacuum Contactor7200-Volt max. reversingRoll-Out design800-Amp7200-Volt max. Isolating Switch10 10 Main bus enclosure.

6 NEMA1 Enclosure DimensionsContactor Catalog SystemSJA50VW430 Vacuum NormallyBreakClosed PolesA- Drawout UsageO- OEM DesignNormallyS- SlideoutOpen Poles25- 2500 Volt50- 5000 Volt4- 400 Amp72- 7200 Volt8- 800 AmpVacuum BreakW- BottleM- Metric BottleOld Catalog System - Starters (with Isolating Switch, Power Fuses, Contactor, etc.)11 - 202 - 25 L 210 - Manual2 - 200 A11 - Magnetic4 - 400 A13 - Wound Rotor7 - 700 A14 - Synchronous8 - 800 A17 - Air ConditioningL - Air Break2 - Full VoltageV - Vacuum3 - Solid StateJ - Vacuum4 - Resistor5 - Reactor25 - 2500 V6 - Auto-tranformer33 - 3300 V7 - part Winding50 - 5000 V8 - Wye-Delta72 - 7200 V9 - Multispeed 2 - Non-Load Break, Fused Switch0 - Non-Reversing1 - Non-Load Break, 1 - ReversingNon-Fused SwitchStarter Catalog System * 1985 to 1997H202S4GH- Air BreakVoltage ClassV- Vacuum Break Drawout E- 2400 VS- Vacuum Break Slideout G- 4160 VType of StarterContactor Amp202- FVNRR ating212- FVR2- 200 Amp502- Reactor4- 400 Amp602- Autotransformer7- 700 Amp702- part Winding Enclosure8- 800 Amp802- Wye-Delta902- Multispeed *Refer to Price List 8810 for complete catalog system MV Motor ControlVacuum Break SJ PartsEffective.

7 March 2000 Page 3 Contactor Catalog Numbering System Prior to 198525L 2LF 25 H43025- 2500 VLF- Air Break33- 3300 VSJ- Vacuum50- 5000 V72- 7200 V25- 2500 V33- 3300 VL- Air Break50- 5000 VV- Vacuum72- 7200 VJ- VacuumH- Air Break2- 200AV- Vacuum4- 400AJ- Vacuum7- 700A8- 800A2- 200A4- 400A7- 700A8- 800 ANormallyOpenPolesNormallyClosed PolesCurrent Starter Catalog Numbering System - effective Nov. 1997S210 SBEP osition 1 (Contactor Type )Position 7 (Voltage)S = 400A Vacuum SlideoutA = 2400 VAC 60 HzR = 400A Vacuum RolloutB = 3000 VAC 60 HzE = 800A Vacuum RolloutC = 3300 VAC 60 HzD = 400A Vacuum Narrow DesignD = 3600 VAC 60 HzW/StabsE = 4160 VAC 60 HzPosition 2 (Starter Type)F = 4800 VAC 60 Hz2 = Full Voltage, Non-reversingG = 5500 VAC 60 Hz3 = Full Voltage, ReversingH = 6000 VAC 60 Hz4 = Reduced Voltage Solid State Soft StartJ = 6300 VAC 60 Hz5 = Reduced Voltage, ReactorK = 6600 VAC 60 Hz6 = Reduced Voltage, AutotransformerL = 6900/7200 VAC 60 Hz7 = Reduced Voltage, Reactor, ReversingZ = Unknown Voltage8 = Reduced Voltage, Autotransformer, ReversingPosition 6 (Enclosure Type)Position 3 ( Motor Type)A = No Enclosure (NEMA 1 Doors)

8 1 = Induction, Single SpeedB = Type 1 General Purpose2 = Induction, Two Speed, Two WindingC = Type 1 with Gasketed Doors3 = Induction, Two Speed, One WindingD = Type 2 Drip Shield4 = SynchronousE = Type 12 Dustight6 = Wound RotorF = Type 3R Outdoor Non-WalkinPosition 4 (Synchronous Type)G = Type 3R Outdoor Non-Walkin 72 High0 = Non-SynchronousH = Type 3R Outdoor Walkin1 = Brush Type Mark V SynchronousJ = Type 1 Half High (NEMA 1 Only)3 = Brush Type Synchronous Relay Panel K = Type 1 Half High wuth Gasketed Doors4 = Brushless Type Synchronous Relay Panel L = No Enclosure (NEMA 3/12 Doors)5 = Brushless Type Synchronous Mark VPosition 5 (Disconnect Switch)S = Isolation SwitchA = Mechanical Future W/CoverF = Electrical Future W/Cover PlateG = Electrical Future W/Isolation SwitchP = No Isolation Switch, Cover Plate Only400 Amp, 7200 Volt Max. Roll-Out SJA Vacuum Break ContactorAMPGARD MV Motor ControlVacuum Break SJ SeriesCutler-HammerRenewal PartsPage 4 effective : March Primary Fuses(Page 18)CPT Primary Fuse Clips(Page 10)Tool Kit (Page 17)L-64 Interlocks(Page 17)Magnet AssemblyComplete with Coil(Page 10)12 Prong Plug(Page 17) Control Coil(Page 10)Contactor Fuse Clips(Page 11)Vacuum BottleSub Assemblies(Page 11)L-63 Interlocks( pages 10, 17)Test Plug(Page 17) Control Power Transformers (CPT)(Page 17)Phase Barriers(Page 10)Front ViewRear ViewAMPGARD MV Motor ControlVacuum Break SJ PartsEffective: March 2000 Page 5400 Amp, 7200 Volt Max.

9 Slide-Out SJS Vacuum Break ContactorCPT Primary Fuse(Page 18)CPT Primary Fuse Clips(Page 10)Tool Kit (Page 17)L-64 Interlocks(Page 17)Magnet AssemblyComplete with Coil(Page 10) Control Precables(Page 11) Control Coil(Page 10)Test Plug(Page 17)Contactor Fuse Clips(Page 11)Vacuum BottleSub Assemblies(Page 11) Control Power Transformers (CPT)(Page 17)Phase Barriers(Page 10)Front ViewRear ViewRenewal PartsAMPGARD MV Motor ControlVacuum Break SJ SeriesCutler-HammerPage 6 effective : March Amp, 7200 Volt Max. Vacuum Break ContactorContactor with 120-Volt Control transformer and two normally open and two normally closed interlocks. To determine proper complete contac-tor style number, refer to the photograph showing both sizes of Control transformers. The smaller Control transformer with a height dimensionof 5 inches is rated 600-Volt amp at 4160 volts and 750-Volt amp at 2300-volts. The larger Control transformers with a height of 7 inches israted 2 KVA at either 2300 or shipping weight 150 lbs.

10 (68kg.)Roll-Out Desgn (SJA)FrontRearDescription * Style NumberComplete 2300V contactor with 750 VAcontrol transformer, 60 HzComplete 2300V contactor with 2 KVAcontrol transformer, 60 HzComplete 4160V contactor with 600 VAcontrol transformer, 60 HzComplete 4160V Contactor with 2 KVAcontrol transformer, 60 HzFor contactor with 240-Volt AC Control , order similar to style num-ber 2147A45G0_, except 240-Volt AC SJA contactors supplied after October 1988 with pull-a-partterminal blocks, order SJS precable Style No. 2147A15G_, frompage 11 for field main contactor is used in reversing, autotransformer, multi-speed starter, or has potential transformer connection order linefingers Style No. 2147A49G01 from page 10 for field mounting. If main contactor must be mechanically interlocked with other con-tactor, order mechanical interlock arm Style No. 2147A43G14from page 12 for field mounting.* Rotate interference bar 180 degrees if used with old, narrow flange doorssupplied prior to July 1983.


Related search queries