FOAMULAR 250. Extruded Polystyrene (XPS) Rigid foam Insulation Product Data Sheet 250 Extruded Polystyrene (XPS) Versatile applications: sheathing, Rigid foam Insulation is made with foundation walls, masonry Owens Corning's patented cavity walls1. Hydrovac process technology Not for use in roofing. For under strict quality control roofing applications, use measures, which makes it highly FOAMULAR THERMAPINK . resistant to moisture and permits Extruded Polystyrene (XPS). the product to retain its high Insulation . R-value year after year even after exposure to moisture and freeze/ Product type thaw cycling. Minimum compressive strength Energy-Saving1, Moisture of 25 psi Resistant XPS Insulation Key Features Wide selection of sizes and Excellent long-term stable thicknesses astm C578 Type IV, 25 psi insulating performance at R-5. minimum Available in straight, tongue and per inch3. groove, or scored square edge Description Exceptional moisture resistance, Owens Corning FOAMULAR long-term durability Compliant with building codes 250 Extruded Polystyrene and standards Limited lifetime warranty4.

Product Data Sheet FOAMULAR® 50 Extruded Polystyrene XPS Rigid Foam Insulation Energy-Saving1, Moisture Resistant XPS Insulation ASTM

Tags:

  Astm, Foam, Rigid, Polystyrene, Insulation, Extruded, Extruded polystyrene xps rigid foam insulation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Extruded Polystyrene XPS Rigid Foam Insulation …

1 FOAMULAR 250. Extruded Polystyrene (XPS) Rigid foam Insulation Product Data Sheet 250 Extruded Polystyrene (XPS) Versatile applications: sheathing, Rigid foam Insulation is made with foundation walls, masonry Owens Corning's patented cavity walls1. Hydrovac process technology Not for use in roofing. For under strict quality control roofing applications, use measures, which makes it highly FOAMULAR THERMAPINK . resistant to moisture and permits Extruded Polystyrene (XPS). the product to retain its high Insulation . R-value year after year even after exposure to moisture and freeze/ Product type thaw cycling. Minimum compressive strength Energy-Saving1, Moisture of 25 psi Resistant XPS Insulation Key Features Wide selection of sizes and Excellent long-term stable thicknesses astm C578 Type IV, 25 psi insulating performance at R-5. minimum Available in straight, tongue and per inch3. groove, or scored square edge Description Exceptional moisture resistance, Owens Corning FOAMULAR long-term durability Compliant with building codes 250 Extruded Polystyrene and standards Limited lifetime warranty4.

2 (XPS) Rigid foam Insulation is maintains 90% of R-value a closed cell, moisture-resistant Product Applications and covers all astm C578. Rigid foam board well suited High-performance FOAMULAR . properties to meet the needs for a wide 250 Extruded Polystyrene (XPS). variety of building applications. The only XPS foam to have Rigid foam Insulation : FOAMULAR 250 Extruded achieved GREENGUARD Gold Retards the transmission of Polystyrene (XPS) Rigid foam Certification water vapor and moisture in Insulation is great for many The only XPS foam with masonry walls residential and commercial certified recycled content . construction applications such Provides continuous Insulation certified by SCS Global Services as wall furring, perimeter/ over steel stud framing, in to contain a minimum 20%. foundation, cavity wall, pre- insulated concrete sandwich recycled content cast concrete, under slab, crawl panel walls, in masonry unit Will not corrode, rot or cavity walls, or when used spaces, sheathing and other support mold growth FOAMULAR 250 with non-penetrating, surface Zero ozone depletion potential mounted furring systems over Extruded Polystyrene (XPS) Rigid with 70% less global warming masonry or concrete walls foam Insulation is classified as a Type IV product when tested potential than our previous Insulates and retains its in accordance with astm C578 formula properties in below grade and provides a long-term thermal Reusable perimeter and foundation performance of R-5 per inch.

3 Applications, or directly Lightweight, durable Rigid foam beneath the concrete slab to Like all FOAMULAR XPS panels are easy to handle and complement the insulating Insulation products, FOAMULAR install sheathing envelope around the Easy to saw, cut or score building framing 1 Savings vary. Find out why in the seller's fact sheet FOAMULAR 250 Extruded on R-values. Higher R-values mean greater insulating power. 3 R means the resistance to heat flow; the higher the Polystyrene (XPS) Rigid foam 2 Not for use in roofing. For roofing applications, R-value, the greater the insulating power. Insulation is great for below use FOAMULAR THERMAPINK Extruded 4 See actual warranty for complete details, limitations Polystyrene (XPS) Rigid foam Insulation . and requirements. grade applications. Extruded FOAMULAR 250. Extruded Polystyrene (XPS) Rigid foam Insulation Product Data Sheet Polystyrene (XPS) Insulation is Typical Physical Properties1. resistant to degradation from FOAMULAR 250 Extruded Polystyrene (XPS) Rigid foam Insulation the components of common Property Test Method2 Value soils and will retain its insulating Thermal Resistance3, R-Value (180 day) minimum, hr ft 2 F/Btu (RSI, C m2 /W).

4 Performance characteristics @ 75 F (24 C) mean temperature astm C518. even after prolonged exposure 3/4" Thickness 1" Thickness ( ). ( ). to moisture 11/2" Thickness ( 2" Thickness 10 ( ). Provides a weather resistant 21/2" Thickness ( ). barrier (when joints are sealed) 3" Thickness 15 ( ). 4" Thickness 20 ( ). to enhance the building's @ 40 F ( C) mean temperature resistance to air and moisture 3/4" Thickness ( ). penetration 1" Thickness 11/2" Thickness ( ). ( ). 2" Thickness ( ). Technical Information 21/2" Thickness ( ). 3" Thickness ( ). This product is combustible. 4" Thickness ( ). A protective barrier or thermal Long Term Thermal Resistance, LTTR-Value3, minimum hr ft 2 F/Btu (RSI, C m2 /W). barrier is required as specified in @ 75 F (24 C) mean temperature CAN/ULC S770-03. the appropriate building code. For 3/4" Thickness 1" Thickness N/A. ( ). additional information, consult 11/2" Thickness ( ). MSDS or contact Owens Corning 2" Thickness ( ).)

5 21/2" Thickness ( ). World Headquarters at 3" Thickness ( ). 1-800-GET-PINK . 4" Thickness ( ). Compressive Strength4, minimum psi (kPa) astm D1621 25 (172). All construction should be Flexural Strength5, minimum psi (kPa) astm C203 75 (517). Water Absorption 6, maximum % by volume astm C272 evaluated for the necessity to Water Vapor Permeance7, maximum perm (ng/Pa s m2) astm E96 (86). provide vapor retarders. See Dimensional Stability, maximum % linear change astm D2126 current ASHRAE Handbook of Flame Spread 8, 9 astm E84 5. Fundamentals. Smoke Developed 8, 9, 10 astm E84 45-175. Oxygen Index8, minimum % by volume astm D2863 24. FOAMULAR 250 Extruded Service Temperature, maximum F ( C) 165 (74). Linear Coefficient of Thermal Expansion, in/in/ F (m/m C) astm E228 x 10 -5 ( x 10 -5). Polystyrene (XPS) Rigid foam 1. Properties shown are representative values for 1" thick material, unless otherwise specified. Insulation is a non-structural 2. Modified as required to meet astm C578.

6 Material and must be installed on 3. R means the resistance to heat flow; the higher the value, the greater the Insulation power. This Insulation must be installed properly to get the marked R-value. Follow the manufacturer's instructions carefully. If a manufacturer's framing which is independently fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at braced and structurally adequate the time of testing. Because Rigid foam plastic Insulation products are not all aged in accordance with the same to meet required construction standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR XPS Insulation is provided from testing at two mean temperatures, 40 F and 75 F, and from two aging (conditioning) techniques, 180 day real- and service loading conditions. time aged (as mandated by astm C578) and a method of accelerated aging sometimes called Long Term Thermal Resistance (LTTR) per CAN/ULC S770-03.

7 The R-value at 180 day real-time age and 75 F mean temperature is commonly used to compare products and is the value printed on the product. FOAMULAR XPS Insulation 4. Values at yield or 10% deflection, whichever occurs first. can be exposed to the exterior 5. Value at yield or 5%, whichever occurs first. 6. Data ranges from to value shown due to the level of precision of the test method. during normal construction 7. Water vapor permeance decreases as thickness increases. cycles. During that time some 8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions. fading of color may begin due to 9. Data from Underwriters Laboratories Inc. classified. See Classification Certificate U-197. 10. A STM E84 is thickness-dependent, therefore a range of values is given. UV exposure, and, if exposed for extended periods of time, some degradation. Once covered, the generally unharmed and still degradation or dusting of the deterioration stops, and damage useful Insulation .

8 Polystyrene surface may begin. It is limited to the thin top surface is best if the product is covered layers of cells. Cells below are within 60 days to minimize FOAMULAR 250. Extruded Polystyrene (XPS) Rigid foam Insulation Product Data Sheet Product and Packaging Data FOAMULAR 250 Extruded Polystyrene (XPS) Rigid foam Insulation Material Packaging Extruded Polystyrene closed-cell foam , astm C 578 Type IV, 25 psi minimum Shipped in poly-wrapped units with individually wrapped or banded bundles. Product Dimensions Pallet (Unit) Dimensions Square Board Bundles Pieces Pieces Thickness Thickness (in) x Width (in) (typical) Width (ft) x feet per feet per per per per (in) x Length (in) Length (ft) x Height (ft) Pallet Pallet Pallet Bundle Pallet Edges 3/4 3/4 x 24 x 96 4x8x8 4,096 3,072 8 32 256. 3/4 x 24 x 96 (Half unit) 4x8x4 2,048 1,536 4 32 128. 3/4 x 48 x 96 4x8x8 4,096 3,072 8 16 128. 3/4 x 48 x 96 (Half unit) 4x8x4 2,048 1,536 4 16 64. 3/4 x 48 x 108 4x9x8 4,608 3,456 8 16 128.

9 3/4 x 48 x 120 4 x 10 x 8 5,120 3,840 8 16 128. 1 1 x 24 x 96 4x8x8 3,072 3,072 8 24 192. 1 x 24 x 96 (Half unit) 4x8x4 1,536 1,536 4 24 96. 1 x 48 x 96 4x8x8 3,072 3,072 8 12 96. 1 x 48 x 96 (Half unit) 4x8x4 1,536 1,536 4 12 48. 1 x 48 x 108 4x9x8 3,456 3,456 8 12 96 Square Edge, Scored Square 11/2 x 24 x 96 4x8x8 2,048 3,072 8 16 128. Edge, Tongue &. x 48 x 96 4x8x8 2,048 3,072 8 8 64 Groove 2 2 x 24 x 96 4x8x8 1,536 3,072 8 12 96. 2 x 24 x 96 (Half unit) 4x8x4 768 1,536 4 12 48. 2 x 24 x 108 4x9x8 1,728 3,456 8 12 96. 2 x 48 x 96 4x8x8 1,536 3,072 8 6 48. 21/2 x 24 x 96 4x8x8 1,152 2,880 8 9 72. x 48 x 96 4x8x8 1,152 2,880 4 9 36. 3 3 x 24 x 96 4x8x8 1,024 3,072 8 8 64. 3 x 48 x 96 4x8x8 1,024 3,072 8 4 32. 4 4 x 24 x 96 4x8x8 768 3,072 8 6 48. 4 x 48 x 96 4x8x8 768 3,072 8 3 24. 1. Available lengths and edge configurations vary by thickness. See for current offerings. Other sizes may be available upon request. Consult your local Owens Corning representative for availability.

10 FOAMULAR Extruded XPS Insulation . Do not cover Standards, Codes Compliance Polystyrene (XPS) Insulation has a FOAMULAR XPS Insulation Meets astm C578 Type IV. maximum service temperature of either stored (factory wrapped or UL Classified. 165 F. Taking simple precautions unwrapped), or partially installed, A copy of UL. during construction can minimize with dark colored (non-white), Classification the potential for heat related or clear (non-opaque) coverings Certificate U-197. damage. Install only as much and leave it exposed to the is available at FOAMULAR XPS Insulation sun. Examples of such coverings as can be covered in the same include but are not limited day. For horizontal applications, to filter fabrics, membranes, See UL ER8811-01 at always turn the print side down temporary tarps, clear astm E119 Fire Resistance so the black print does not show polyethylene, etc. If improperly Rated Wall Assemblies. See to the sun which may at times covered, and exposed to the right for act as a solar collector, raising the combination of sun, time and details.