FLOCSFLOCSThis page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a CONVEYING PRODUCTSD escriptionPageAccess Methods ..262 evacuation Units ..263 Direct Access Drain Coupling ..264 Oil Thief Sampling Access Conversion Kits ..266 Standard Vehicle Kits ..266 Large Capacity Vehicle Kits ..2672024 ..2672047 ..2662083 ..2652089 ..266-267412 ..2664411 ..2674412 ..2675657 ..266-2675602 ..266-267900729 ..266-267FC350 ..266-267FD14 ..264FF293 ..267FF317 ..267FF322 ..267FF380 ..267FF395 ..267FF400-0A ..266FF401-0A.

FLOCS This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product. 263 EVACUATION

Tags:

  Eaton, Evacuation, Colf

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FLOCS - Eaton

1 FLOCSFLOCSThis page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a CONVEYING PRODUCTSD escriptionPageAccess Methods ..262 evacuation Units ..263 Direct Access Drain Coupling ..264 Oil Thief Sampling Access Conversion Kits ..266 Standard Vehicle Kits ..266 Large Capacity Vehicle Kits ..2672024 ..2672047 ..2662083 ..2652089 ..266-267412 ..2664411 ..2674412 ..2675657 ..266-2675602 ..266-267900729 ..266-267FC350 ..266-267FD14 ..264FF293 ..267FF317 ..267FF322 ..267FF380 ..267FF395 ..267FF400-0A ..266FF401-0A.

2 266 Part NumberPageFF402-0A ..266FF403-0A ..266FF404-0A ..266FF405-0A ..266FF406-0A ..266FF407-0A ..266FF408-0A ..266FF409-0A ..266FF410-0A ..266FF411-0A ..266FF412-0A ..266FF413-0A ..266FF428 ..266FF429 ..266FF430 ..266FF431 ..266FF432 ..266FF433 ..266FF434 ..266FF435 ..266FF436 ..266FF437 ..266FF438 ..266FF439 ..266FF440 ..266FF441 ..266 Part NumberPageFF833 ..267FF834 ..267FF943 ..267FF944 ..267FF945 ..267FF946 ..267FF947 ..267FF948 ..267FF949 ..267FF9330A ..263FF9315 ..263FF9516 ..263FF9300 ..265FF9363/FF9270 ..266-267FF1187 ..266-267FF11041-0A.

3 266FF11042 ..266FF10452-0A ..266FF11301 ..266FF11302-0A ..266FF11303 ..266FF11498-0A ..266FF11499 ..266FF11825-0A ..266FF11826 ..266 SectionPagesHose15-67 Fittings68-180 Adapters and181-228 Tube FittingsSectionPagesSwivel Joints229-244 Flexmaster Joints245-260 FLOCS 261-267 SectionPagesQuick Disconnect268-345 CouplingsAccess., Equipment &346-393 Assembly InstructionsTechnical Data394-433 RETURN TO CONTENTS PAGEFLOCSThis page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a ACCESS METHODSD irect AccessThe FLOCS Direct Access Conversion Kit uses theAeroquip-developed FD14 Drain Coupling as an alternativeto the standard remote hose kit.

4 This coupling design per-mits easy, one-hand connection and disconnection of theevacuation unit s :1. Remove old drain Replace with the proper size FD14 Drain Push on rubber protective installation is now :When it is time to change the oil:1. Remove the rubber protective Connect the evacuation hose to the FD14 Activate the pump, and the used oil is quickly evacuated to storage Disconnect the evacuation hose and replace the rubber AccessThe FLOCS Remote Access Conversion Kit replaces theold drain plug with a 90 degree pan adapter, AeroquipFC350 AQP hose and quick-disconnect :1.

5 Remove old drain Replace with the proper size FF1187 pan Install mounting bracket (and optional 90 degreeadapter).4. Attach hose assembly to FF1187 pan adapter andmounting Attach coupling and dust installation is now :When it is time to change the oil:1. Remove the dust Connect the evacuation hose to the Activate the pump, and the used oil is quickly evacuatedto storage Disconnect the evacuation hose and replace the page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a 30A Air-powered Unit(Part No. FF9330A-01) Remote Access(Part No.)

6 FF9330A-19) Direct AccessThe FLOCS 30A Oil- evacuation Unit is a versatile, air-powered unit designed to be used where an air-powersource is available, and electrical units may present a firehazard. This unit can be adapted for use either on a lubetruck or in a maintenance FLOCS 30A unit can be used with equal effectiveness onvehicles with small oil-pan capacities (taxicabs, deliverytrucks, school buses, etc.), medium capacities (highwayequipment, tree-harvesting equipment, etc.), or largecapacities (mining or construction equipment, etc.). Speed,ease of operation and versatility make the FLOCS 30A thebest rapid oil- evacuation unit for many 15 Electric-powered Unit(Part No.

7 FF9315-01) Remote Access(Part No. FF9315-28) Direct AccessThe FLOCS 15 Oil- evacuation Unit is electric powered andis designed for use in fleet maintenance service bays. Usedin conjunction with overhead oil-dispensing reels, theFLOCS 15 speeds oil changes in large fleets. In some mul-tilane maintenance shops, the FLOCS 15 concept has beenused to implement a fast-lane operation, with one lane setaside for high-frequency, routine maintenance functions,leaving the other lanes free for more complex and time-consuming FLOCS 15 is compatible with existing oil service equip-ment and can be installed quickly, without interrupting nor-mal maintenance operations.

8 It discharges old oil into exist-ing storage tanks and shuts off automatically when the oldoil has been evacuated. A signal light goes off when theevacuation is Piston pump2. 5 cfm air-operated motor (80-150 psi)3. Override button4. Cycle gauge5. 15' of 1" suction hose*6. Coupling half**7. Suction strainer8. 1/4" air-supply coupling9. 1/4" air-supply nipple10. 1" NPT discharge port* FLOCS 30A Oil- evacuation Unit with 25' hose assembly is ordered by part numberFF9330A-100 (Remote Access), FF9330A-20 (Direct Access).**Differs with access 3/4 hp electric motor, 115V AC, 20 amp2.

9 Gear pump3. Cycle-run starter button4. Cycle-run signal light5. 15' of 1" suction hose*6. Coupling half**7. Suction strainer8. 115V AC flow-control switch9. Backflow check valve with a 3/4" NPT discharge port* FLOCS 15 Oil- evacuation Unit with 30' hose assembly is ordered by part numberFF9516-01 (Remote Access), FF9516-02 (Direct Access).**Differs with access method.(4.)(10.)(5.)(7.)(6.)(1.)(2.)(3.) (8.)(9.)(3.)(5.)(7.)(6.)(1.)(2.)(4.)(8.) (9.)FLOCSThis page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a ACCESS DRAINCOUPLINGMin.

10 Ass yAssemblyCouplingThreadDimensional DataTorque(IncludesGasketCapSizeSize (P)AB(Ft-Lbs)Gasket & Cap)(Copper-Crush)(Buna-N)-061/2-20 *FD14-1002-01-06FD14-1206-01FD14-1204-06 -06M18 x 1/420*FD14-1002-02-06FD14-1206-04FD14-12 04-06-06M14 x *FD14-1002-03-06FD14-1206-02FD14-1204-06 -0611/4-18 *FD14-1002-05-06FD14-1206-11FD14-1204-06 -061-18 *FD14-1002-06-06FD14-1206-07FD14-1204-06 -067/8-18 *FD14-1002-07-06FD14-1206-06FD14-1204-06 -065/8-18 *FD14-1002-08-06FD14-1206-03FD14-1204-06 -063/4-16 *FD14-1002-09-06FD14-1206-04FD14-1204-06 -067/8-14 *FD14-1002-10-06FD14-1206-06FD14-1204-06 -06M24 x 2 *FD14-1002-11-06FD14-1206-07FD14-1204-06 -069/16-18 *FD14-1002-12-06FD14-1206-02FD14-1204-06 -0611/8-12