GypCeiling MF - british-gypsum.com
Refer to construction detail 7, relating to double layer 12.5mm Gyproc SoundBloc linings. With concrete floors the high mass of the construction means that high levels of acoustic performance can be achieved when the GypCeiling MF ceiling is suspended by conventional means, i.e. Gypframe MF8 Strap Hangers or Gypframe FEA1 Steel Angle.
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Product Data Sheet - british-gypsum.com
www.british-gypsum.comadditives for extra fire protection. Where to use. Use it in partitions, ceilings and steel encasement . systems to achieve the fire performance required in domestic separating walls, corridors, garages and steel encasements. Certifications. Environmental Product Declaration (EPD) available Click here. Product information. Composition
Identification
www.british-gypsum.comTable 1: Glasroc F FireCase fixings. Board thickness (mm) Min. fixing length Board-to-board fixing Board-to-metal fixing 15 Glasroc F FireCase Screws 40mm ... Gyproc plasterboard lining. Refer to construction detail 16 on page 3.14. – For further information please please refer to Technical Support on .
Gyproc Moisture Resistant - british-gypsum.com
www.british-gypsum.comGyproc Moisture Resistant Product Data Sheet Introduction Suitable as a base for tiling in wet use areas. Also used for external soffits in sheltered positions.
C05. S02. P02 – P30 ShaftWall - british-gypsum.com
www.british-gypsum.comC05 Introduction Specialist partitions Specialist partitions This section details specialist lightweight systems where high-security, curved, fire or …
C05. S05. P02 – P05 GypWall secure - british …
www.british-gypsum.comC05. S05. P02 – P05 GypWall secure Including C05. S01. P02 Specialist partitions introduction This section includes updated information, added since it was first
Robustness SYSTEM DESIGN PRINCIPLES
www.british-gypsum.comImportantly for design, the greatest rate of strength loss is in the range of 400°C to 600°C. Using fire design codes such as the Structural Eurocodes EC3-1.2 and EC4-1.2 (designated BS EN 1993-1-2 and BS EN 1994-1-2), the load on the structure at the time of the fire can be calculated by treating it as an accidental limit state.
Gyproc SoundBloc 12 - british-gypsum.com
www.british-gypsum.comEither cut the board with a plasterboard saw, or score the front face paper with a sharp knife, snap it over a straightedge, then cut the back face paper. Cut holes for things like socket boxes using a utility saw. Fixing Fix the board with the decorative side facing outwards to receive finishes. Install fixings at least 13mm from cut
Related documents
Introduction to Steel Doors and Frames - Steel Door Institute
steeldoor.orgThe Steel Door Institute created ANSI/SDI A250.6 Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames as a guide to door reinforcement and the installation of door hardware. It should be referenced by hollow metal door installers. The correct hardware must be selected to ensure the door and frame are properly reinforced.
Southern Steel Accessories - Southern Folger Detention Locks
www.southernfolger.comDoor is constructed of 10 gauge steel plate flanged 1-3/4” all around, hung on two Model 203FS hinges and locked with a Model1010Adeadlock. Steel frame is 7 gauge formed plate. Specify type of wall construction to determine anchor requirements. Prime painted. 590 HINGED ACCESS DOOR A C C E S S O R I E S ACCESS DOORS AND PANELS F13
MASTER SPECIFICATIONS Division 08 OPENINGS
www.northwestern.edua. Type: As indicated in the Door and Frame Schedule. b. Thickness: 1-3/4 inches (44.5 mm). c. Face: Uncoated, cold-rolled steel sheet, minimum thickness of (16 0.053 inch gage). d. Edge Construction: Model 1, Full Flush. e. Core: Minimum 20 gauge vertical steel stiffener spaced at not more than 6inches - apart.
Lifetime Guarantee Why Specify Prime Painted Galvanneal ...
www.madero.caDoor Elevations DD CE CEHG Steel Doors Standard Duty Frames Universal Frame for 1 3 / 4" Steel or Wood Doors Daybar’s 16 gage Universal Frame has been engineered to excel in both masonry and drywall applications for added convenience. T his frame can be converted from a nominal 6" cement block butt masonry frame to a 4 7 / 8" wrap around ...
Fire Damper Installation Instructions - E.H. Price
www.ehpricesales.comThe fire barrier opening shall be larger than the damper to allow for thermal expansion and ease of installation. When steel stud/gypsum or wood stud/gypsum partitions are being used then refer to Fig. 1-3 for additional information and details. A. Dampers Assemblies Using Angles Methods (see note 4a) shall be a minimum of 1/
StoTherm ci XPS Booklet - Sto Corp.
www.stocorp.comconstruction or materials, at changes in building height, at expansion, control, and cold joints in construction, and at floor lines in multi-level wood frame construction. Provide minimum of ½” (13mm) wide perimeter sealant joints at all penetrations through the wall (windows, doors, mechanical, electrical,
ARCHITECTURAL SYMBOLS GENERAL NOTES ABBREVIATIONS
biznet.ct.gov1.structural steel components shall conform to the current specifications for the design, fabrication and erection of structural steel for buildings as adopted by the american institute of steel construction. 2.unless otherwise noted, all structural steel shall be in accordance with astm specifications a-36.