Example: quiz answers

Identity code: Meta MTMa Diaphragm Metering Minent …

ProMinent Meta 4 Labeling:0 Standard, with logoIdentity code : Meta mtma Diaphragm MeteringPumpsSeries:MTMaMeta Diaphragm -type Metering pumpVersion aHMain driveAAdd-on drive Pump version:NewCross Reference Conversion Table from former version to new ident code version12065*043531020012086*0344110263 FormerIdent CodeFormerIdent CodeFormerIdent Code12108*035301033020-1301206512-260072 16151-2601017312130*1017309395**15-13012 08610-26006260121-2601021610130102160440 012-1301210820-53005265101-2601026009173 102600452710-1301213015-53004353121-5300 544007216054400366220-2601013012-5300344 1101-53005530062600553003790**15-2600917 310-5300353005265* for PC, PP, TT versions, max.

Pr o Minent Meta–5 ProMinent ® Meta MTMaH Diaphragm metering pumps 1436/4 Select appropriate motor horsepower from the Table of Capacities below. Motor is not included with pump.

Tags:

  Code, Team, Pumps, Identity, Motor, Diaphragm, Metering, Metering pumps, Identity code, Meta mtma diaphragm metering, Mtma

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Identity code: Meta MTMa Diaphragm Metering Minent …

1 ProMinent Meta 4 Labeling:0 Standard, with logoIdentity code : Meta mtma Diaphragm MeteringPumpsSeries:MTMaMeta Diaphragm -type Metering pumpVersion aHMain driveAAdd-on drive Pump version:NewCross Reference Conversion Table from former version to new ident code version12065*043531020012086*0344110263 FormerIdent CodeFormerIdent CodeFormerIdent Code12108*035301033020-1301206512-260072 16151-2601017312130*1017309395**15-13012 08610-26006260121-2601021610130102160440 012-1301210820-53005265101-2601026009173 102600452710-1301213015-53004353121-5300 544007216054400366220-2601013012-5300344 1101-53005530062600553003790**15-2600917 310-5300353005265* for PC, PP, TT versions, max.

2 145 psig (10 bar)** models 09395 and 03790 run at 1450 RPM maximum mtma H03530 PCAT0004000 Liquid end materials:PPPolypropylenePCPVCTT carbon reinforced PTFESSS tainless steelSeal material:AViton EEPDMTPTFED iaphragm version:TStandard Diaphragm with PTFE faceValve springs:0 Without valve springs1 With 2 valve springs (Hastelloy C4, 1 psig)Hydraulic connection:APVC clamp nut & insertBPP clamp nut & insertCPVDF clamp nut & insertDSS clamp nut & insertMotor mount:0 Add-on pump, no motor4 Without motor , with NEMA 56C flangeEnclosure Rating:0 StandardStroke sensor:0 Without stroke sensor1 With stroke sensor (retrofitable) Namur signalStroke length adjustment:0 Manual (standard)1 With 3P stroke positioning motor , 230V, 50/60 Hz2 With 3P stroke positioning motor , 115V, 50/60 HzCWith stroke positioning motor , 0-20 mA, 50/60 HzDWith stroke positioning motor , 4-20 mA, 50/60 HzViton is a registered trademark of DuPont Dow ElastomersProMinent Meta 2 Specifications.

3 MetaGeneral:Housing construction:Acrylic resin coated cast aluminumDrive:Cam and spring-followerMotor mounting flange:Fits all NEMA 56C frame motors ( motor not included with pump)Gear ratios and stroke frequencies(with 1725 RPM motor ):10:1 = 172 SPM, 12:1 = 144 SPM, 15:1 = 115 SPM, 20:1 = 86 SPMM otor coupling:Flexible coupling included with pumpMaximum motor RPM:1725 Stroke frequency control:Remote or automatic frequency control optional with DC SCR driveor AC inverterStroke counting:Available with optional stroke counterLubrication:Oil lubricatedRecommended oil:Mobil Gear Oil 634, ISO VG 460 Oil quantity:Approximately quarts (550 mL)Recommended oil change interval:5,000 hoursSeparation of drive from liquid end:An air gap separates the drive from the liquid end to prevent crosscontamination of oil and process fluid in the event of Diaphragm (MTMaH/MTMaA) or packing (MTKaH/MTKaA) MTMaH/MTMaA:Pump type.

4 Mechanically actuated Diaphragm ( Diaphragm threaded directlyto reciprocating shaft) Diaphragm :PTFE-faced EPDM with steel coreMax. stroke " (4 mm) - All except 6 mm types listed " (6 mm) - Pump types 10200, 10263, 10330, 09395, 04400, 04527,03662 and length adjustment:Manual, in 1% increments, 2 turns = 100%. Motorized stroke length failure indication:Optional - see accessoriesWetted materialContinuousShort Termof construction optionsPP = polypropylene176 F (80 C)212 F (100 C)and maximum fluidPC = PVC113 F (45 C)140 F (60 C)temperatures:TT = carbon-filled PTFE194 F (90 C)248 F (120 C)SS = 316 stainless steel194 F (90 C)248 F (120 C)Check valves:Single ball (Note: Check valve bodies for 6 mm PP, PC and T pumps arePVDF with ceramic valve balls).

5 Repeatability:When installed and operated according to instructions, better than 2% ofrated MTKaH/MTKaA:Pump type:Packed-plunger (plunger threaded directly to reciprocating shaft)Max. stroke " ( mm)Stroke length adjustment:Manual, in increments, 10 turns = 100%. Motorized stroke lengthcontrol material:SS/aluminum oxide ceramicPacking:Special PTFE ring packingPacking seal method:Self-adjusting spring tensioned packing gland with Hastelloy-C flush port:Packing lubrication/flushing is possible for abrasive or hazardous fluids viathe flush port.

6 Hosebarbs fit 1/2"x 3/8" flexible tubingCheck valves:Double ballRepeatability:When installed and operated according to instructions, better than rated fluid temperature:Continuous = 392 F (200 C); short term = 482 F (250 C)ProMinent Meta 5 ProMinent Meta MTMaHDiaphragm Metering pumps1436/4 Select appropriate motor horsepower from the Table of Capacities below. motor is not included with pump. A pressure relief valve isrequired on the discharge line. Capacities are given for standard 4-pole AC motor at 60 Hz (nominal 1725 RPM).

7 For performance at 50Hz, multiply rated capacity by 5 liftNPSHMax. suction pressureLiquid Endft(m)psig(bar)psig(bar) (5) ( ) ( ) (3) ( ) ( ) (2) ( ) ( ) ProMinent Meta mtma Diaphragm pumps - 4mm Stroke LengthMaximumCapacityStrokingRecommended Suction andShippingback-at maximumrate atMotorDischargeweight **pressurebackpressure1725 RPMH orsepower(w/o motor )New pumpOld pumppsig (bar) threadlbs.(kg)versionversionGPH (L/h) *20-130145(10) (78) ( )12086*15-130145(10) (104) ( )12108*12-130145(10) (130) ( )12130*10-130145(10) (156) ( )1013020-260145(10) (156)30861/23/4 2025( )0917315-260131(9) (208)301151/23/4 2025( )0721612-260109 ( ) (260)301441/23/4 2025( )0626010-26087(6) (312)301721/23/4 2025( ) (5)84(318) 2533( ) ( )112 (424) 2533( ) ( )140 (530) 2533( ) (3)168 (637) 2533( )10173151-260145(10) (208)301153/43/4 2025( )10216121-260145(10)

8 (260)301443/43/4 2025( )10260101-260145(10) (312)301723/43/4 2025( ) (5)140 (530) 2533(15) (5)168 (636) 2533(15)*Maximum 174 psig (12 bar) for 316 stainless steel liquid ends. **Add 10 lbs. for 130/260 SS liquid ends and 20 lbs. for 530 SS liquid ends. ProMinent Meta mtma Diaphragm pumps - NEW 6mm Stroke LengthLiquid End10200260145(10)62(236) ( )10263260145(10)83(314) ( )10330260145(10)103 (392) ( )09395 260131(9)104 (395) ( )0440053058(4)125 (473) ( )0452753058(4)166 (629) ( ) (3)207 (785) ( )03790 (3)208 (790) ( ) Types 09395 and 03790 may only be operated with a 1450 rpm or less motor (50 Hz).

9 Capacities shown are operating at 1450 : Ratings, except types 09395 and 03790, based on a 1725 rpm motor . motor not included -- please refer to the High FlowAccessories Meta 6 ProMinent Meta MTMaA - Diaphragm meteringpump add-on modules and materials1437/4 The ProMinent Meta MTMaA add-on pump modules can be combined with any Meta mtma or MTKa main pump to form duplex ortriplex pumps at rated pressure. Additional add-on pumps can be multiplexed at reduced pressure. If ordered as such, multiplexpumps will be provided completely assembled.

10 A baseplate is recommended, but not required. Meta pumps can be multiplexed in thefield; all the necessary components are supplied with the add-on Meta MTMaA add-on modules may be driven by any Meta mtma or MTKa main pump; however, the frequency of the mainpump will determine the frequency of the add-on pump. For example, a Meta MTMaA10130 with a PVC liquid end may be con-nected to a Meta mtma 12065 with a teflon liquid end, and the resulting frequency of both pumps will be 86 spm. Use the appropriatestroking rate in selecting an add-on pump strokes are 180 out of phase, with no additional horsepower requirement.


Related search queries