Example: quiz answers

Industrial Plugs & Receptacles - CROUSE-HINDS

Industrial Plugs & ReceptaclesProducts & solutions For heavy duty applicationsIndustrial ConnectivityCEAG Products2 EATON S CROUSE-HINDS DIVISION2 EATON'S CROUSE-HINDS IEC 60309 pin and sleeve mechanical interlocksPlug in with IEC 60309 Industrial Plugs and Receptacles for harsh environmentsEaton's CROUSE-HINDS IEC 60309 series Plugs and Receptacles are designed for use in heavy Industrial rated and engineered to provide secure, safe and waterproof connections in the toughest conditions. Easy to install Impact resistant enclosure Low engagement force IP66 compliant when plugged in Self-cleaning lamellar contacts Low transition resistance EATON S CROUSE-HINDS DIVISION 3 Applications: To supply power to portable or fixed electrical equipment, such as welders, motor generator sets, compressors.

Rated current 63 A 63 A 63 A 63 A 63 A Cable entry 1 x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic 1x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic Ø 19 - 34 mm Ø 19 - 34 mm Connecting terminals 2 x 4 – 25 mm 2 with switch 2 x 4 – 35 mm without switch 1 x 4 – 16 mm / with pin cable lug 2) 1 x 35 mm2 1 x 2.5 – 35 mm2 1 x 2.5 – 35 mm2

Tags:

  Switch, Industrial, Receptacles, Trade, Plugs, Industrial plugs amp receptacles

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Plugs & Receptacles - CROUSE-HINDS

1 Industrial Plugs & ReceptaclesProducts & solutions For heavy duty applicationsIndustrial ConnectivityCEAG Products2 EATON S CROUSE-HINDS DIVISION2 EATON'S CROUSE-HINDS IEC 60309 pin and sleeve mechanical interlocksPlug in with IEC 60309 Industrial Plugs and Receptacles for harsh environmentsEaton's CROUSE-HINDS IEC 60309 series Plugs and Receptacles are designed for use in heavy Industrial rated and engineered to provide secure, safe and waterproof connections in the toughest conditions. Easy to install Impact resistant enclosure Low engagement force IP66 compliant when plugged in Self-cleaning lamellar contacts Low transition resistance EATON S CROUSE-HINDS DIVISION 3 Applications: To supply power to portable or fixed electrical equipment, such as welders, motor generator sets, compressors, conveyors, portable tools, lighting systems, and similar equipment In damp or corrosive atmospheres In wet locations In hose down areasFeatures.

2 Mechanically interlocked, dead-front receptacle - plug cannot be engaged or disengaged under load Enclosure has continuous form-in-place gasket Meets OSHA's lockout/tagout requirements - can be padlocked in "OFF" position Industrial switch is horsepower rated for motor load applicationsCertifications and compliances: IEC60309-1 and IEC60309-2 UL Standards: 508, 1682 CSA Standard: Nos. 14, IP66 Standard materials: Enclosure - glass reinforced polyamide (GRP) External Hardware - stainless steel Contacts - brass, nickel plated beryllium copper Contact Carrier - glass fiber reinforced nylon PA66 Applications: Where complete protection against dirt, dust and water jets In damp or corrosive atmospheres In areas prone to vibration, hard use, and abuse In environments that demand safety, ease of use, reliability, and durability Ideal for heavy duty Industrial applications, such as.

3 Shipyards, military, marine/marina environments, pulp and paper, heavy manufacturing, wastewater treatment, portable powerFeatures: Voltage, configured, color coded Watertight Impact- and corrosion-resistant Receptacles mount to Eaton's CROUSE-HINDS back boxes Innovative finger lock keeps cord grip secured Positive grommet seal system at cord entry Funneled wire pockets Lockout/tagout High grade nickel-plated brass pins V0 insulating material Multi-lam sleeve bands, nickel plated beryllium copperCertifications and compliances: IEC60309-1 and IEC60309-2 IEC IP6620 Amp & 30 Amp Certified to CSA No.

4 , and UL168260 Amp & 100 Amp Complies with CSA No. , and UL1682 Standard materials: Enclosure - glass reinforced polyamide (GRP) External hardware - stainless steel Contacts - nickel plated brass lamella contacts and compression lugs Contact carrier - glass fiber reinforced nylon PA66 Plugs , connectors, Receptacles and inletsMechanical interlocksOverview4 EATON S CROUSE-HINDS DIVISIONM echanical cord clamp with innovative locking finger ensures a positive strain relief and corrosion-resistant type 12 nylon wrenching surfaces for tightening down on internal brushing.

5 Ensuring complete watertight seal at cord and ribbed surfaces for positive gripping and handling even in harsh, dirty front housing for easy and accurate identification of mating devices of same coded cap accurately identifies mating plug of correct cap meets NEMA 4X, IP66 hose down copper contacts with self-cleaning, field-proven, multi-lam pressure bands for smooth pin insertion, low heat rise and quality electrical hole for OFF thermoplastic contact carrier provides superior electrical insulation and V flammability mounting footprint fits all existing Eaton's CROUSE-HINDS back socketNickel-plated brass contacts offer long-life corrosion protection.

6 Compression lugs provide reliable mechanical wire wiring pockets for ease of inserting stranded wire. Deep pocket marked X, Y and Z keep bare conductors safely confined and isolated from adjacent wire termination pockets have all screw heads on the same side for easy conductor insertion and quick finger seats into web pockets when cord grip is tightened down, securing back cap in place even under heavy usage and & benefits EATON S CROUSE-HINDS DIVISION 5 OSHA lockout/tagout design fits in the web of an I-beam smallest in the in place mounting feetGRP housing provides superior corrosion protection and impact NPT hubs or metric threaded hubs for IEC connectors Plastic cable glands Metal cable glandsThick, sturdy walls won't warp from hot and cold water washdown.

7 Maintains gasket seal between cover and to wire. Cover removes along an innovative break line that permits full access to internal switch mounting pads allow firm mounting to uneven surfaces. Provides water channel between wall and receptacle cover with lockout/tagout hole for off and groove IP66 watertight sealing system. Continuous raised rib around perimeter of base seats in channel in cover. Channel has seamless foam-in-place silicone gasket which stays in place when cover is socket with mechanical interlock switch6 EATON S CROUSE-HINDS DIVISIONC locking position1standard ground2> 50 V 300-500 Hz: 3 pole < 50 V 300-500 Hz: 4 pole < 50 V 300-500 Hz: 4 pole3< 50-250 V: 3 pole 380-440 V 50/60Hz: 4 pole 220/380-250/440 V 50/60Hz: 5 pole4110-130 V 50/60Hz: 3 pole 110-130 V 50/60Hz: 4 pole 57/110-75/130 V 50/60Hz: 5 pole5277 V 60Hz: 3 pole 600-690 V 50/60Hz: 4 pole 347/600-600/690 V 50/60Hz: 5 pole6200-250 V 50/60 Hz.

8 3 pole 380-415 V 50/60 Hz: 4 pole 200/346-240/415 V 50/60 Hz: 5 pole7480-500 V 50/60 Hz: 3 pole 480-500 V 50/60 Hz: 4 pole 277/480-288/500 V 50/60 Hz: 5 pole8> 250 V DC-voltage9380-415 V 50/60Hz: 3 pole 200-250 V 50/60Hz: 4 pole 120/208-144/250 V 50/60Hz: 5 pole10> 50 V 100-300 Hz: 4 pole11440-460 V 60 Hz: 4 pole 250/400-265/460 V 60 Hz: 5 pole1250-60 Hz: 3 pole1) 50-60 Hz: 4 pole1)Version120/16 A230/32 A460/63 A5100/125 APrefixEaton's CROUSE-HINDS Heavy duty industrialOrdering information for IEC productsPart number descriptionEaton's CROUSE-HINDS Industrial positionA clock face is used to represent the grounding contact position for all female connectors and Receptacles .

9 With the keyway at the bottom, the female ground contact will appear to one of the twelve hour positions. To identify the system voltage, identify the housing color and hour location of the connector or receptacle grounding Socket7 Plug8 Flange Socket9 InletPoles33-pole (2+N+PE)44-pole (3+PE)55-pole (3+N+PE)Type of enclosure0 Moulded Plastic1 Stainless Steel3 Internal Earth Plate5with Aux ContactIEC / NECRIEC VersionLNEC VersionVoltageClock Setting 01 - number1) Output of an isolation transformer with more than 50 V> 50 V 300-500 Hz> 50 V 300-500 Hz> 50 V 300-500 Hz380-440 V 50/60 Hz50-250 V 50/60 Hz220/380- 250/440 V 50/60 Hz110-130 V 50/60 Hz110-130 V 50/60 Hz57/110- 75/130 V 50/60 Hz277 V 60 Hz600-690 V 50/60 Hz347/600- 600/690 V 50/60 Hz380-415 V 50/60 Hz200/346- 240/415 V 50/60 Hz200-250 V 50/60 Hz480-500 V 50/60 Hz277/480- 288/500 V 50/60 Hz480-500 V 50/60 Hz200-250 V 50/60 Hz120/208 144/250 V 50/60 Hz380-415 V 50/60 Hz > 250 V DC-voltage > 50 V 100/300 Hz440-460 V 60 Hz250/400- 265/460 V

10 60 Hz50-60 Hz 1)50-60 Hz 1)3P + N + PE (5 pole)3P + PE (4 pole)2P + PE (3 pole) > 50 V 100/300 Hz > 50 V 100/300 Hz1000 V EATON S CROUSE-HINDS DIVISION 7 Technical data 1) use supplied cable lugsPermissible ambient temperature-40 C up to +55 C Rated voltage690 V~Rated current125 AFrequency50/60 HzExternal back-up fuse, therm. protection: 16 A / 32 A / 63 A / 125 AProtection classIDegree of protection acc. to EN 60529IP66 Plugs and Receptacles - Industrial useacc. to IEC 60309- 1/2 up to 690 VWallsocket with interlock switchWallsocket without switchPlugCouplerFlange Socket / Inlet16 ARated current16 A16 A16 A16 A16 ACable entry1 x M25 8 - 17 mm, 1 x M25 thread plug plastic2 x PG 16 top, 2 x PG 16 bottom 8 - 19 mm (3-pole) / 8 - 21 mm (4-pole) / 12 - 21 mm (5-pole) 8 - 19 mm (3-pole) / 8 - 21 mm (4-pole) / 12 - 21 mm (5-pole)


Related search queries