Custom Type I, III and V optics for better output, zero maintenance and reduced energy consumption Harsh & heavy industrial A Modular design - This contractor-friendly design is ideal for both retrofit and new construction applications.
Tags:
Safe, Intec, Reliable, Effi cient
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Ex-plugs and receptacles 63 A 4/5-pole up to 690 V 1
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS17.0062X Marking accd. to IECEx Ex db eb [ia Ga] IIC/IIB T5 Gb / Ex tb IIIC T80°C Db Permissible ambient temperature -20 °C up to +55 °C (IIC)-40°C up to +40 °C (IIB) Rated voltage 690 V (AC) Rated current 63 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 60947-3 U e ...
Receptacles, Plugs, Conformity, Iecex, Of conformity iecex, Ex plugs and receptacles 63 a
EX-PLUGS AND RECEPTACLES - CROUSE-HINDS
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BKI 04.0002 Marking accd. to IECEx Ex ed [ia] IIC T6/T5 Permissible ambient temperature -20°C up to +40°C 1) Rated voltage up to 400 V, (3-pole) / 690 V, (4-pole) / 500 V, (5-pole) AC Rated current 16 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 U e 250 V / I e 16 A (3-pole) accd.
Ex-e/i Cable Glands - CROUSE-HINDS
www.crouse-hinds.de2.3.4 EATON www.crouse-hinds.de 3.1 Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to EN 60079-0: 2012 Conform with latest stand-ards Cable glands with metric screw-in threads are now standard and had replace the PG cable glands that were formally used. The CEAG plastic cable glands are in accordance with
Global Reference Guide on the Marking of Electrical ...
www.crouse-hinds.deDirective 2014/34/EU (previously 94/9/EG) (ATEX) Marking according to IEC/CENELEC/CSA standard 60079-0 Typical marking of electrical equipment for use in explosive dust atmospheres (EU/ATEX/IECEx): Electrical types of protection for explosive atmospheres due to fl ammable gases, vapours and mists Type Protec-tion level Type of protection Group ...
CEAG ProductsMain Catalogue Part 2: Chapter 2
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS 16.0024 Marking accd. to IECEx Ex e IIC T5/T6 Gb Ex tb IIIC T80°C Db Permissible ambient temperature –20 °C to +40 °C / -55 C to +55 °C (option) Rated voltage 690 V / 550 V1) Terminal cross section max. 3 x 4 mm ...
Certificate, Conformity, Iecex, Iecex certificate of conformity iecex
Industrial Plugs & Receptacles - CROUSE-HINDS
www.crouse-hinds.deRated current 63 A 63 A 63 A 63 A 63 A Cable entry 1 x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic 1x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic Ø 19 - 34 mm Ø 19 - 34 mm Connecting terminals 2 x 4 – 25 mm 2 with switch 2 x 4 – 35 mm without switch 1 x 4 – 16 mm / with pin cable lug 2) 1 x 35 mm2 1 x 2.5 – 35 mm2 1 x 2.5 – 35 mm2
Switch, Industrial, Receptacles, Trade, Plugs, Industrial plugs amp receptacles
Ex-Linear light fittings for fluorescent lamps
www.crouse-hinds.dein hazardous areas The eLLK 92 linear luminaire se-ries for fluorescent lamps com-bines the latest lighting technol-ogy with the requirements of a harsh and hazardous envi-ronment. This luminaire series is available in various sizes as a ceiling mounted light fitting (eLLK) and as a pole-mounted light fitting (eLLM). Long-term safety
Linear light fitting series with new LED module for ...
www.crouse-hinds.deeLLM 92 LED 800A 1/3-1K 1 x 3 – – 1 x M25, Plastic 1 2269 505 101 1 2269 504 101 eLLK 92 LED 400 V-CG-S 2) eLLK 92 LED 400 V-CG-S 2/6-2K 2 x 6 – x 2 x M25, Plastic 2 x M25 1 2265 517 103 1 2265 516 103 eLLK 92 LED 400 V-CG-S 2/6-2M 1) 2 x 6 – x 4 x M20, Metal thread 2 x M25 1 2265 517 111 1 2265 516 111
CEAG Products Ex-Solutions LED Lighting - CROUSE-HINDS …
www.crouse-hinds.defitting series is the ideal solu-tion for lighting tasks in harsh and hazardous environments. Latest lighting technology for a proven lighting concept As a leading manufacturer of ex-plosion-protected luminaires, we have redesigned our revolutionary LED module to fit into the eLLK/M... linear light fitting se-ries. With the new Gen2 modules, our
Champ VMVL LED luminaires - 3,000 to 11,000 lumens
www.crouse-hinds.deWall 4.50 2.04 Angled stanchion 3.50 1.59 Straight stanchion 4.50 2.04 Weights: Model lbs. kg. VMVL-3 to VMVL-7 19.00 8.62 VMVL-9 & VMVL-11 19.20 8.70 VMVL-3 to VMVL-11 40°C 55°C 65°C Class I, Division 2 T5 T5 T4A Class II, Division 1 T5 T4A T4A Simultaneous rating Class I, Division 1 & 2 T3C T3A T3A Class I, Zone 2 AEx nA nR; Ex nA nR T5 T5 ...
Related documents
E cient Conversion of HPLC Instruments between Normal ...
ccc.chem.pitt.edu6 Liquid Chromatography sigma-aldrich.com/hplc ORDER: 800-247-6628 (US ONLY) / 814-359-3441 Reporter 28.5 E!cient Conversion of HPLC Instruments between
Between, Intec, Instruments, Conversion, Hplc, Cient conversion of hplc instruments between
PROBLEMAS RESUELTOS. NOTACIÓN CIENTÍFICA…
www.aulamatematica.comDP. - AS - 5119 – 2007 Matemáticas ISSN: 1988 - 379X Abel Martín www.aulamatematica.com 1 PROBLEMAS RESUELTOS. NOTACIÓN CIENTÍFICA…
Super-E Premium Effi cient Motors
www.esrmotors.com2 www.baldor.com Going Beyond the Industry Standard in Premium Efficient Motors Baldor’s Super-E® motors are another example of our commitment to provide reliable performance, while exceeding customer expectations. Standard on All Baldor Motors: Exxon Polyrex® EM Polyurea Grease It’s a fact: Bearing failure is the #1 mechanical reason for motor failure.
Enabling effi cient policy implementation - Oracle
www.oracle.comEnabling effi cient policy implementation A report from the Economist Intelligence Unit Sponsored by Oracle
Policy, Oracle, Implementation, Intec, Enabling, Enabling effi cient policy implementation
FL 100 Floor Unit FLOOR Whisper Quiet And E˜cient …
smithsep.comVector Floor Unit by Smith’s Environmental Products FL 100 Floor Unit VECTOR FLOOR Whisper Quiet And E˜cient Operation BY SMITH’S ENVIRONMENTAL PRODUCTS The Vector (FL100) Recessed Floor Unit Is A Complete Fan Convector
Operations, Floor, Intec, Quiet, Whisper, Floor whisper quiet and e cient, Floor whisper quiet and e cient operation
Towel Rail Installation & User Instr uctions Read these ...
www.free-instruction-manuals.comTowel Rail Installation & User Instr uctions Read these instructions carefully before installing the towel rail. Failure to correctly fl ush the system and add suffi cient protection
Checklist of Essential Features of Age-friendly Cities
www.who.intPAGE 4 ☐ Regular information and broadcasts of interest to older people are off ered. ☐ Oral communication accessible to older people is promoted. ☐ People at risk of social isolation get one-to- one information from trusted individuals. ☐ Public and commercial services provide friendly, person-to …