CEAG Products Ex-Solutions LED Lighting - CROUSE-HINDS …
fitting series is the ideal solu-tion for lighting tasks in harsh and hazardous environments. Latest lighting technology for a proven lighting concept As a leading manufacturer of ex-plosion-protected luminaires, we have redesigned our revolutionary LED module to fit into the eLLK/M... linear light fitting se-ries. With the new Gen2 modules, our
Tags:
Series, Ries, Luminaire, S eries
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Linear light fitting series with new LED module for ...
www.crouse-hinds.deeLLM 92 LED 800A 1/3-1K 1 x 3 – – 1 x M25, Plastic 1 2269 505 101 1 2269 504 101 eLLK 92 LED 400 V-CG-S 2) eLLK 92 LED 400 V-CG-S 2/6-2K 2 x 6 – x 2 x M25, Plastic 2 x M25 1 2265 517 103 1 2265 516 103 eLLK 92 LED 400 V-CG-S 2/6-2M 1) 2 x 6 – x 4 x M20, Metal thread 2 x M25 1 2265 517 111 1 2265 516 111
Ex-Linear light fittings for fluorescent lamps
www.crouse-hinds.dein hazardous areas The eLLK 92 linear luminaire se-ries for fluorescent lamps com-bines the latest lighting technol-ogy with the requirements of a harsh and hazardous envi-ronment. This luminaire series is available in various sizes as a ceiling mounted light fitting (eLLK) and as a pole-mounted light fitting (eLLM). Long-term safety
Champ VMVL LED luminaires - 3,000 to 11,000 lumens
www.crouse-hinds.deWall 4.50 2.04 Angled stanchion 3.50 1.59 Straight stanchion 4.50 2.04 Weights: Model lbs. kg. VMVL-3 to VMVL-7 19.00 8.62 VMVL-9 & VMVL-11 19.20 8.70 VMVL-3 to VMVL-11 40°C 55°C 65°C Class I, Division 2 T5 T5 T4A Class II, Division 1 T5 T4A T4A Simultaneous rating Class I, Division 1 & 2 T3C T3A T3A Class I, Zone 2 AEx nA nR; Ex nA nR T5 T5 ...
Safe. Reliable. Effi cient. - CROUSE-HINDS
www.crouse-hinds.deCustom Type I, III and V optics for better output, zero maintenance and reduced energy consumption Harsh & heavy industrial A Modular design - This contractor-friendly design is ideal for both retrofit and new construction applications.
Ex-plugs and receptacles 63 A 4/5-pole up to 690 V 1
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS17.0062X Marking accd. to IECEx Ex db eb [ia Ga] IIC/IIB T5 Gb / Ex tb IIIC T80°C Db Permissible ambient temperature -20 °C up to +55 °C (IIC)-40°C up to +40 °C (IIB) Rated voltage 690 V (AC) Rated current 63 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 60947-3 U e ...
Receptacles, Plugs, Conformity, Iecex, Of conformity iecex, Ex plugs and receptacles 63 a
EX-PLUGS AND RECEPTACLES - CROUSE-HINDS
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BKI 04.0002 Marking accd. to IECEx Ex ed [ia] IIC T6/T5 Permissible ambient temperature -20°C up to +40°C 1) Rated voltage up to 400 V, (3-pole) / 690 V, (4-pole) / 500 V, (5-pole) AC Rated current 16 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 U e 250 V / I e 16 A (3-pole) accd.
Ex-e/i Cable Glands - CROUSE-HINDS
www.crouse-hinds.de2.3.4 EATON www.crouse-hinds.de 3.1 Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to EN 60079-0: 2012 Conform with latest stand-ards Cable glands with metric screw-in threads are now standard and had replace the PG cable glands that were formally used. The CEAG plastic cable glands are in accordance with
Global Reference Guide on the Marking of Electrical ...
www.crouse-hinds.deDirective 2014/34/EU (previously 94/9/EG) (ATEX) Marking according to IEC/CENELEC/CSA standard 60079-0 Typical marking of electrical equipment for use in explosive dust atmospheres (EU/ATEX/IECEx): Electrical types of protection for explosive atmospheres due to fl ammable gases, vapours and mists Type Protec-tion level Type of protection Group ...
CEAG ProductsMain Catalogue Part 2: Chapter 2
www.crouse-hinds.deIECEx Certificate of Conformity IECEx BVS 16.0024 Marking accd. to IECEx Ex e IIC T5/T6 Gb Ex tb IIIC T80°C Db Permissible ambient temperature –20 °C to +40 °C / -55 C to +55 °C (option) Rated voltage 690 V / 550 V1) Terminal cross section max. 3 x 4 mm ...
Certificate, Conformity, Iecex, Iecex certificate of conformity iecex
Industrial Plugs & Receptacles - CROUSE-HINDS
www.crouse-hinds.deRated current 63 A 63 A 63 A 63 A 63 A Cable entry 1 x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic 1x M50 Ø 22 - 35 mm, 1 x M50 thread plug plastic Ø 19 - 34 mm Ø 19 - 34 mm Connecting terminals 2 x 4 – 25 mm 2 with switch 2 x 4 – 35 mm without switch 1 x 4 – 16 mm / with pin cable lug 2) 1 x 35 mm2 1 x 2.5 – 35 mm2 1 x 2.5 – 35 mm2
Switch, Industrial, Receptacles, Trade, Plugs, Industrial plugs amp receptacles
Related documents
SLWLED SERIES - Tamlite
www.tamliteusa.comThe SLWLED wide strip series is suitable for general propose lighting in a wide variety of environments, such as commercial, industrial, retail or warehouse lighting applications. ... Provides an interface between a group or zone of luminaires and the ENCELIUM EDGE Controller enabling group or zone-based control of multiple luminaires.
High Performance Perimeter Slot (HP-WS)
www.finelite.comLUTRON TUNABLE WHITE DRIVER OPTION: LUT-TW (0.1% T-Series 2-Channel Digital Tunable White (PSQ Series)). MOUNTING OPTIONS HANGING HARDWARE: The standard mounting (Threaded Rod - TR) option eliminates the need to install luminaires prior to the slot be-ing framed. Luminaire mounts on threaded rods. Gasket runs length of
Public Lighting Design Manual - Ergon Energy
www.ergon.com.aua substitute for the AS/NZS1158 series but serves as a basis for public lighting design for the DNSPs in Queensland. Historically HPS and MV luminaires have been used for minor road applications. It is recognised however that the use of mercury vapour lamps is now being discouraged. Accordingly designs
Hi-lume 1% 2-Wire LED Driver Forward-Phase Control Overview
www.lutron.com® Luminaires V2.0 and Lutron Drivers at www.lutron.com for availability dates of compliant products. • LED drivers need to meet certain performance criteria in order for the completed luminaires to comply with Title 24 requirements as detailed in CEC-400-2015-037-CMF. All models meet these performance criteria
BLT Series LED 2BLT4 - Acuity Brands
img.acuitybrands.comBLT Series LED 2BLT4 2' x 4' LED COMMERCIAL INDOOR BLT-2X4 Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE —The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design that offers a clean, versatile style and volumetric distribution.
Champ VMV LED cULus Cl. I, Div. 2, Groups A, B, C, D 2L ...
www.eaton.com(for Luminaires) • cUL Listed to CSA standard C22.2 No. 137 (Electric Luminaires for Hazardous Locations) • CSA 60079-11 • CSA 60079-0 IEC/EN standards (pending): • IEC/EN 60079-0, IEC/EN 60079-15, IEC/EN 60079-11, IEC/EN 60079-31 • IEC 60529 • IEC 60598 National Electrical Manufacturers Association (NEMA): • NEMA 250 Model Typical
COMPLIANT FINELITE Series 12 LED Indirect/Direct - 2E, 3E ...
www.finelite.comSep 24, 2019 · Series 12 LED is a luminaire with a classic curved shape and is available with 2, 3 or 4 light engines. The luminaire uses mid-power LEDs for long life and enhanced performance. It is available with a
Champ MLLA - Eaton
www.eaton.comSeries MLLA Champ MLLA linear LED luminaire Color temperature BLANK Cool white, 5000K, 70 CRI N Neutral white, 4000K, 70 CRI W Warm white, 3000K, 80 CRI Voltage UNV1 120-277 VAC; 127-300 VDC UNV34* 347-480 VAC Finish BLANK Natural aluminum P Painted (gray, epoxy) WH Painted (white, epoxy) Lens BLANK Clear glass S891 Diffused glass S903 Clear ...